Series AL modular style lubricator provides accurate lubrication of downstream equipment. The oil drop rate is adjustable depending on equipment requirements. The AL modular design allows connection with other SMC air preparation equipment. Atomizes lubricant into fine particles at uniform rate, Drip rate easily monitored with sight dome, Can be refilled under pressure, High-response

Body Size: 40, Thread: F (G), Port Size: 04 (1/2), Mounting: w/o Mounting Option, Bowl: 8 (Metal Bowl w/Level Gauge), Lubricant Exhaust Port: w/o Drain Cock, Flow Direction: Left to Right, Pressure Unit: Pressure Unit: MPa; Temp Unit: °C

Body Size: 4000, Thread: F (G), Port Size: 04 (1/2), Option: None, Voltage: 5 (24 VDC), Lead Wire: KO (M12 Connector, w/o Cable), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: B (Push-turn Locking Slotted Type), Flow Direction/Pressure Unit: Flow Direction: Left to Right

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: None, Thread: F (G), Port Size: 04 (1/2), Output Specification: K (OUT 1: Analog 4 to 20mA; OUT 2: Analog 4 to 20mA), Temperature Sensor: T (Temperature Sensor), Lead Wire: Lead Wire w/M8 Connector, 3m, Unit Specification: M (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C), Bracket: R (Bracket), Calibration Certificate

Set Flow: 10 (1~10l/min), Thread: F [G(PF)], Port Size: 04 (1/2), Terminal Box: 0 [w/o Terminal Box (Contact 1ab)], Neon Lamp: 0 (w/o Neon Lamp), CE-compliant: Q (CE-compliant)

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: L2T (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: Â

Body Size: 40, Backflow: w/o Backflow Function, Thread: F (G), Port Size: 04 (1/2), Options: w/o Mounting Option, Set Pressure: 1 (0.02 to 0.2 MPa Setting), Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Units: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa

Body Size: 40, Thread: F (G), Port Size: 04 (1/2), Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: 8 (Metal Bowl w/Level Gauge), Semi-Standard 2: Standard

Body Size: 40, Backflow: w/o Backflow Function, Thread: F (G), Port Size: 04 (1/2), Mounting: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa, Exhaust Mechanism: Relieving Type, Flow Direction: Left to Right, Knob: Downward, Pressure Unit: Name Plate and Pressure Gauge in Imperial Units; MPa

Body Size: 40, Back Flow: w/o Backflow, Thread: F (G), Port Size: 04 (1/2), Options: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: 6 (Nylon Bowl), Bowl Guard: None, Drain Port: J (Body Size 20: 1/8; Body Size 30 & 40: 1/4), Exhaust Mechanism: Relieving Type, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Product: MPa, Â

Body Size: 40, Back Flow: w/o Backflow, Thread: F (G), Port Size: 04 (1/2), Options: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: 2 (Metal Bowl), Bowl Guard: None, Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Product: MPa, °C; Pressure Gauge: MPa

Body Size: 40, Thread: F (G), Port Size: 04 (1/2), Mounting: None, Semi-Standard, Body Size 10: 2 (Metal Bowl), Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard

Body Size: 40, Back Flow: w/o Backflow, Thread: F (G), Port Size: 04 (1/2), Options: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: 8 (Metal Bowl w/Level Gauge), Bowl Guard: None, Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: Flow Direction: Left to Right, Drain Cock w/Barb Fitting: None, Pressure Units: Product: MPa, °C; Pressure Gauge:

Body Size: 40, Thread: F (G), Port: 04 (1/2), Option: Standard, Attachment: Standard, Semi-Standard 1: 8 (Metal Bowl w/Level Gauge), Semi-Standard 2: Standard

Body Size: 40, Thread: F (G), Port Size: 04 (1/2), Mounting: None, Semi-Standard, Body Size 10: 6 (Nylon Bowl), Semi-Standard, Body Size 20: R (Flow Direction: Right to Left), Semi-Standard, Body Size 30, 40, 50 & 60: Standard

Body Size: 40, Thread: F (G), Port Size: 04 (1/2), Option: w/o Bracket; w/o Auto Drain, Semi-Standard 1: 8 (Metal Bowl w/Level Gauge), Semi-Standard 2: Standard

Body Size: 40, Back Flow: w/o Backflow, Thread: F (G), Port Size: 04 (1/2), Options: w/o Mounting Option, Set Pressure: 0.05 to 0.85 MPa Setting, Bowl: Polycarbonate Bowl, Bowl Guard: None, Drain Port: w/Drain Cock, Exhaust Mechanism: Relieving Type, Flow Direction: R (Flow Direction: Right to Left), Drain Cock w/Barb Fitting: None, Pressure Units: Product: MPa, °C; Pressure Gauge: MPa

Body Size: 40, Thread: F (G), Port: 04 (1/2), Option: Standard, Attachment: T (T-spacer), Semi-Standard 1: Standard, Semi-Standard 2: Standard

Body Size: 40, Thread: F (G), Port Size: 04 (1/2), Option: Standard, Semi-Standard 1: 8 (Metal Bowl w/Level Gauge), Semi-Standard 2: Standard

Body Size: 40, Thread: F (G), Port Size: 04 (1/2), Option: Standard, Attachment: Standard, Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard