Body Size: 4 (1/2), Type: 2 (Elbow), Control Type: 1 (Meter-in), Indicator Direction: None (0°), Thread: N (NPT), Port Size: 04 (1/2), Width Across Flats: 9mm, Tubing: 10 (ø10), Seal: S (w/Sealant)
Body Size: 40, Thread: Rc, Port Size: 04 (1/2), Option: D (N.O. Float Type Auto Drain), Attachment: V1 (3-Port Valve for Residual Pressure Release; Mounting: V+AF+AR), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Standard
Rated Flow Range: 501 (5 to 500 L/min), Thread Type: N (NPT), Port Size: 04 (1/2), Output Specifications: B (Out 1: PNP; Out 2: PNP), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: M (SI Unit Only), Option 2: No Bracket, Calibration Certificate: A (Yes)
Body Size: 40, Thread: Rc, Port Size: 04 (1/2), Option: DM (D + M), Attachment: V1 (3-Port Valve for Residual Pressure Release; Mounting: V+AF+AR), Semi-Standard 1: 12 (1 + 2), Semi-Standard 2: Standard
Max Operating Pressure: 3 (3.5 MPa), Construction: 40 (Element Upward Removal, Threaded), Port Size: 04 [1/2 Threaded, 15 (1/2) Flange SSA], Pressure Indicator: 2 (Differential Pressure Indication Switch), Relief Valve: 0 (Relief Valve), Fluid: 0 (Petroleum), Element: P (Paper), Filtration: 20μm
Body Size: 4 (1/2), Type: 2 (Elbow), Control Type: 1 (Meter-in), Indicator Direction: 0°, Thread: N (NPT), Port Size: 04 (1/2), Applicable Tubing O.D.: 11 (ø3/8"), Seal: S (w/Sealant)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4), Sealant: without Sealant, Push lock: A (Push-lock)
Body Size: 2 (1/8, 1/4), Type: 2 (Elbow), Control Type: 0 (Meter-out), Control Range: FSM (1 to 50 mm/s), Indicator Window Direction: 0° , or None for FC, FM, Thread: R, Port Size: 01 (1/8), Width Across Flats [H]: 9mm or None for Body Size 2, Tube Size: 04 (ø4)
Function: 2 (2 Position, Double), Model: 0 (Plug-in), Body Option: 0 (Standard), Pilot: Internal Pilot, Voltage: 1 (100 VAC, 50/60 Hz), Lead Wire: F (Plug-in), Surge Suppressor: Z (with Light/Surge Voltage Suppressor), Manual Override: Non-locking Push Style (Flush), Port Specification: Side Ported, Port Size: 04 (1/2)
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Ported), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: M (M Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: U (Surge Suppressor w/Light Non-polar), Manual Override: Non-locking Push Style, A, B Port Size: 04 (Base Mounted Sub-plate 1/2), Thread: N (NPT)
Flow Switch Type: 5 (Remote Sensor Unit), Rated Flow Range: 20 (2~16L/min), Return Unit: None, Thread: N (NPT), Port Size: 04 (1/2), Flow Switch Output: 1T (Remote Sensor Unit; Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None, Temp. Analog 1 to 5 V; Temperature Sensor: Yes)
Function: 2 (2 Position Double), Piping: 4 (Base Mounted), Exhaust: 4 (Base), Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: M (M Plug Connector w/Lead Wire 300mm), Light/Surge Suppressor: U (With light/surge voltage suppressor (Non-polar type)), Manual Override: Non-locking Push Type, Port Size: 04 (1/2), Thread: N (NPT)
Terminal 1/2, Non Plug-in Standard 1/2), Thread: F (G)
Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: B (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Valve; w/Stop Valve), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: 1T (Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector)
Body Size: 3, Set Pressure: 2 (0.01 to 0.8 MPa), Exhaust Direction: 2 (Rear Exhaust), Thread: Rc, Port Size: 04 (1/2), Mounting: B (w/Bracket), Flow Direction: Left to Right, Knob: Upward
Valve; w/Stop Valve), Return Port Size: 04 (1/2), Flow Switch Output Specifications: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Flow Switch Unit Specifications: F (Integrated Display: gal/min; Accumulated Flow: gal; Temp.: °F)
Rated Flow Range: 501 (5 to 500 L/min), Thread Type: Rc, Port Size: 04 (1/2), Output Specifications: A (Out 1: NPN; Out 2: NPN), Option 1: w/Lead Wire and M8 Connector, 3m, Unit Specification: Unit Selection Function, Option 2: R (w/Bracket), Calibration Certificate: A (Yes)