SMC Corporation of America
Elite Part Number Search
Search Results "VEX3121-015LOZ-F"

0FFF 4095 5.25 21 0FFF 4095 10.5 5.25 21 0F1C 3868 5 20 0F3D 3901 10 5 20 0800 2048 3 12 0800 2048 5.25 2.625 10.5 00E4 228 1 4 0 0 0 0 0 0 0 0.75 3 Byte0 Byte1 CH0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0 0 0 0 MSB AD LSB Byte2 Byte3 CH1 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 0 0 0 0 MSB AD LSB -20No.EX-OMN0037CN-A -1010 V-55 V-2020 mA AD (ab) [V] [mA] 16 10 -1010 V -55 V -2020 mA F

02 kPa 0 2 kPa -0.2 kPa -32No.PS-OMG0001CN-H 4 A -33No.PS-OMG0001CN-H 0.56 mm 2 n 31n +3.5n -1 2 n 31n +3.5n -1 -34No.PS-OMG0001CN-H PSE3T 90 -35No.PS-OMG0001CN-H Revision history C D E F G H [2018 7 ] 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com Note: Specifications are subject to change without prior

Size: 3 (30), Body Material: A (Aluminum), Seal Material: F (FKM), Port Size: 03 (3/8), Thread Type: F (G), Rated Voltage: 6 (12 VDC), Electrical Entry: DZ (DIN Terminal w/Light, w/Surge Voltage Suppressor)

Model Type: Standard, Piping: F (Direct), Port Size: 10 [1" (25A)], Port Thread: F (G), Silencer: w/o Silencer, Pilot Port Size: 1/4", Orifice Diameter: A (Pilot Valve Orifice Diameter: for ø3mm to ø5mm)

Model Type: Standard, Piping: F (Direct), Port Size: 06 [3/4" 20A)], Port Thread: F (G), Silencer: w/o Silencer, Pilot Port Size: 1/4", Orifice Diameter: A (Pilot Valve Orifice Diameter: for ø3mm to ø5mm)

Model Type: Standard, Piping: F (Direct), Port Size: 06 [3/4" 20A)], Port Thread: F (G), Silencer: w/o Silencer, Pilot Port Size: 1 (1/8")

Model Type: Standard, Piping: F (Direct), Port Size: 14 [1 1/2" (40A)], Port Thread: F (G), Silencer: w/o Silencer, Pilot Port Size: 1 (1/8")

Magnet: None, Series: A2, Mounting: F (Rod Flange), Tube Material: F (Steel Tube), Bore Size: 100mm, Port Thread: Rc, Stroke: 125mm

Magnet: None, Series: A2, Mounting: F (Rod Flange), Tube Material: F (Steel Tube), Bore Size: 63mm, Port Thread: Rc, Stroke: 175mm

Function: 1 (2 Position Single), Body Option: 00 (Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 06 (Sub-plate Plug-in Terminal 3/4, Non Plug-in Standard 3/4), Thread: F (G)

Function: 1 (2 Position Single), Body Option: 00 (Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 10 (Sub-plate Plug-in Terminal 1, Non Plug-in Standard 1), Thread: F (G)

Function: 1 (2 Position Single), Body Option: 00 (Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 10 (Sub-plate Plug-in Terminal 1, Non Plug-in Standard 1), Thread: F (G), CE Compliant: Q (CE-compliant)

Function: 2 (2 Position Double), Body Option: 00 (Plug-in Type Sub-plate, Standard), Pilot Type: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: F (Plug-in Conduit w/Terminal), Surge Suppressor: Z (Light & Surge Suppressor), Port Size: 06 (Sub-plate Plug-in Terminal 3/4, Non Plug-in Standard 3/4), Thread: F (G)

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 04 (1/2), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C),

Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: F (G), Port Size: 03 (3/8), Output Specification/Temperature Sensor: F (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA; Temp.: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C)

.: PNP; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F), Bracket: R (w/Bracket), Calibration Certificate: None

.: PNP; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: F (Instantaneous Flow: gal/min, Accumulated Flow: gal, Temperature: °F), Bracket: None, Calibration Certificate: None