SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q22-05-DO"

Do not repair the fittings or patch the tube for reuse. KC 4. After operation at a high temperature, leakage may occur due to time dependent change of the tube material. If leakage occurs, remove the tube, cut off the connecting part of the tube, and connect to the piping again. Check if the tube dimension accuracy is within the recommended tolerance.

Do not repair or patch the replaced tubing or fittings for reuse. 1. Do not use in environments or locations where there is a danger of damage to fittings and tubing. For fitting and tubing materials, refer to specifications and construction drawings, etc. 2. Provide shade in locations which receive direct sunlight. Caution 1.

" 0.006 8.3 Note 2) Rotating torque under pressure 0.5 MPa Note 3) Do not use the fittings with a leak tester or for vacuum retention because they are not guaranteed for zero leakage.

As the connected actuator will start operating due to this manual operation, be sure to confirm that it is safe to do so beforehand. Ex. 1) Cable length: 300 mm DXT1215T-5W1U-01m(-X1) Symbol for electrical entry MNon-locking push type Push the manual override button all the way down. 2.

When installing and removing an element, do not scratch or damage it by touching the corners of the case, etc. When washing the element, do not wipe it using a stiff brush or rag. Refer to page 529 for Microswitch for differential pressure indication switch. r Removing the element Rotate the air breather (cap) one-third of a turn counterclockwise and remove it.

Do not use a lubricator on the inlet side of the product, as the bleed mechanism can malfunction. Caution 1. For emergency action in the event of setting failure or leakage from the relief port, refer to Troubleshooting in the Operation Manual of the product. Piping Warning Air Preparation Equipment 1.

Do not use a lubricator on the inlet side of the product, as the bleed mechanism can malfunction. Caution IRV 1. For emergency action in the event of setting failure or leakage from the relief port, refer to Troubleshooting in the Operation Manual of the product. VEX SRH Piping Warning SRP SRF 1.

Do not use a lubricator on the inlet side of the product, as the bleed mechanism can malfunction. Caution IR 1. For emergency action in the event of setting failure or leakage from the relief port, refer to Troubleshooting in the Operation Manual of the product. IRV VEX Piping Warning SRH SRP 1.

With 2 auto switches Same surface Different surfaces 6 A A-6 15 Auto switch model REA REB Auto Switch D-M9 D-M9W 6 B B-6 REC The auto switch is mounted by slightly displacing it in a direction (cylinder tube circumferential exterior) so that the auto switch and lead wire do not interfere with each other.

Do not service or attempt to remove product and machinery/ equipment until safety is confirmed. 1. The inspection and maintenance of machinery/equipment should only be performed after measures to prevent falling or runaway of the driven objects have been confirmed. 2.

Do not weld an arm to the cylinder. 4) Make sure to use a speed controller and adjust it to more than 1sec. when changing from clamping to unclamping (or vice versa).

Do not use a lubricator on the inlet side of the product, as the bleed mechanism can malfunction. Caution 1. For emergency action in the event of setting failure or leakage from the relief port, refer to Troubleshooting in the Operation Manual of the product. Piping Warning Air Preparation Equipment 1.

Do not bring objects that are sensitive to magnetism near the cylinder. The magnet is built into the cylinder. Do not bring magnetic disks, cards or tapes near the cylinder. Data may be lost. 5. If the cylinder is operated vertically with heavy loads, measures must be taken to prevent rapid extension of the piston rod when starting to operate in the downward direction.

With 2 auto switches Same surface Different surfaces 6 A A-6 15 Auto switch model REA REB Auto Switch D-M9 D-M9W 6 B B-6 REC The auto switch is mounted by slightly displacing it in a direction (cylinder tube circumferential exterior) so that the auto switch and lead wire do not interfere with each other.

(Do not use any tools.) The initial exhaust rate is adjusted by turning the adjustment nut counterclockwise. x Opening of the initial exhaust valve (valve S) When the pilot pressure is applied to the pilot port S, the valve S is removed from the valve S seal assembly, and the valve opens the adjusted amount.

When using the male thread mounting type product, do not loosen the bottom nut shown in the figure below. (The bottom nut is intended to secure the connection between the bracket for the adapter connection and the male thread.) PD3 Circuit without release valve (Usage example of vacuum connection) V V PD2 PD2 Supply valve EXH. P Pressure sensor Do not loosen this nut.

Do not use it for mounting. Otherwise, the adjustment at shipment may deviate. 792

Do not drop, hit or apply excessive shock to the product. Even if the body is not damaged, the internal components may be damaged, leading to a malfunction. Wiring/Piping Warning 1. Power supply required to the product is 24 VDC and 1 A.

Do not use this aftercooler in an area that has viscous dust (electrostatic paint powder, oily particles, etc.). If it must be used under such conditions due to unavoidable circumstances, please contact SMC beforehand.