SMC Corporation of America
Elite Part Number Search
Search Results "VV2Q22-20-DO-00T"

Do NOT make upward piping. 2. Float type auto-drain (N.C.) DO NOT pipe upwards. (ANR)}. 2) Set pressure more than 0.1 MPa. 2. Float type auto-drain (N.C.) 1) Compressor can be used even if energy is under 3.7 kw. 2) Set pressure more than 0.15 MP 14-3-14

Do not place a magnetic object near the pressure switch. Unintended operation may result. 2. Do not apply strong shocks (over 300 m/s2) to the pressure switch to prevent the switch from damage. AV AU AF Caution Flow rate (/min (ANR)) Inlet pressure (MPa) 1. Release the lock to adjust the pressure. After the adjustment, engage the lock.

Do not service machinery/equipment or attempt to remove component until safety is confirmed. 1) Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe locked-out control positions. 3-12-6 A

Soft Start-up Valve AV2000/3000/4000/5000 How to Order AV 00 1 G 20 02 Flow direction Nil R Left to right Right to left Soft start-up valve Manual override Nil: Non-locking push type (Flush) B: Locking type (Tool required) C: Locking type (Lever) Body size 20 30 40 50 1/4 3/8 1/2 3/4,1 Thread type Rc G NPT Nil F N Light/Surge voltage suppressor None Nil S Z With surge voltage suppressor (

*1 Soft Start-up Valve AV2000-A/3000-A/4000-A/5000-A Series 2(A) Symbol How to Order (P)1 3(R) *1 CE compliant AV 00 20 02 B B 1 D q w e r t y u i o A Electrical entry Grommet DIN terminal AC V DC V V V q Body size 20 30 40 50 Symbol Description w Thread type Nil Rc V V V V N NPT V V V V F G V V V V + 02 1/4 V 03 3/8 V 04 1/2 V 06 3/4 V 10 1 V + e Port size 1(P), 2(A) a Mounting Nil

Do not disassemble the trunnion style. Seal kit includes a grease pack (40, 50: 10 g, over 63: 20 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) Cushion valve seal NBR Cylinder tube gasket NBR Disassembly/Replacement 1. Please consult with SMC when the rod seal is to be replaced.

Do not disassemble the trunnion style. Seal kit includes a grease pack (40, 50: 10 g, over 63: 20 g). Order with the following part number when only the grease pack is needed. Grease pack part no.: GR-S-010 (10 g), GR-S-020 (20 g) Cushion valve seal NBR Cylinder tube gasket NBR Disassembly/Replacement 1. Please consult with SMC when the rod seal is to be replaced.

Do not place a magnetic object near the pressure switch. Unintended operation may result. 2. Do not apply strong shocks (over 300 m/s2) to the pressure switch to prevent the switch from damage. AV AU AF Caution Flow rate (/min (ANR)) Inlet pressure (MPa) 1. Release the lock to adjust the pressure. After the adjustment, engage the lock.

Do not apply external force to the coil section. When tightening is performed, apply a wrench or other tool to the outside of the piping connection parts. Port Air operated Solenoid 12 (P1) External pilot External pilot 2. Do not warm the coil assembly with a heat insulator, etc. Use tape, heaters, etc., for freeze prevention on the piping and body only.


Existing SY3000/5000/7000/9000 series part numbers: SYS□□20, SY□□40, and SY□□45
Plug-in type SY3000/5000/7000 series part numbers: SYS□□00, SY□□30, SY□□01, and SY□□31

When the valves are purchased as a single unit, the presence or absence of a gasket is as follows.
For existing SY3000/5000/7000/9000 series body ported valves (SY□□20), a gasket is not included.

(Do not use a tool.) For setting the initial pumped amount, turn it counterclockwise. 2. Opening the valve (valve S) for initial pumping When air pressure is applied to the pilot port 1(P) and the initial pumping solenoid valve is energized, the S valve will release from the S valve seal assembly and open to the adjusted angle. 3.

When the element comes to the end of its life immediately replace it with a new filter or replacement element (cartridge type). 4 Do not disconnect and replace the one-touch fitting. Environment Warning Warning 1. Do not use the product in the following environments, which could cause failure. Seals the element, cover and fitting body. A place exposed to water, steam or oil.

Do not service machinery/equipment or attempt to remove component until safety is confirmed. 1) Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe locked-out control positions. 4-17-4

Filtration rating has to be 5m or smaller. 3(R) Model VHS2500 VHS3500 VHS4500 VHS5500 A 60 78 85 136 B 20 29 32 56 C 12.8 12.8 12.6 32 D 40 53 70 90 E 44 53 64 80 F 33 42 49 65 G 28 29 36 54 H 7.5 7.5 10 10 3.6-18

Do not apply a lateral load on the main body during or after mounting. 3. When the silencer has loosened due to vibrations from the mounted equipment, mount the silencer after applying an anti-loosening agent to the thread. 612

H D DO 2 01 1 8 1 8 Base mounted 02 1 4 1 4 Caution Refer to front matters 58 and 59 for Safety Instructions and pages 3 to 7 for 3/4/5 Port Solenoid Valve Precautions.

Note 1) Do not use the power supply of inrush current prevention type for the controller power supply. When conformity to UL is required, the electric actuator and controller should be used with a UL1310 Class 2 power supply. 560

No gap Booster regulator Air tank Booster regulator A B C D E F G H I J K L M Grooves There should be no damage or dust O-rings VBAT05A1 VBA10A VBA11A 150 374 370 307 163 160 100 200 Rc 3/8 257 60 Rc 1/4 20 Air tank There is a slight play on the diagonal parts.

Do not disassemble the power clamp cylinder. The power clamp cylinder consists of a completely sealed structure in order to protect it from welding spatter. Do not disassemble, except for when replacing any of the replaceable parts, as the performance may deteriorate. 10 Power Clamp Cylinder Variations Web Catalog.