.) ; Port size: 01 (1/8), 02 (1/4), 03 (3/8), 04 (1/2); Pilot port thread: Rc, NPT
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT) Speed controller standard in-line style; Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2; Port sizes: M3, M5, 01, 02, 03, 04
Body Size: 30, Thread: N (NPT), Port: 03 (3/8), Option: G (Round Pressure Gauge w/Limit Indicator), Attachment: Standard, Semi-Standard 1: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 25, 30, 40, 50, 55, 60), Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)
Configuration: 3 (3 Position Closed Center), Sealant: 1 (Rubber Seal), Function: Y (Low Wattage 0.5W), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: w/Light and Surge Suppressor, Manual Override: Non-locking Push Style, 1: 1, Porting Specification: Side Ported, Port Size: 03 (3/8), Thread: N (NPT)
Stations: 3 Stations (Note: 1 Station is Required for Serial Unit Mounting), Port Size: 03 (Rc3/8), Electrical Entry Direction: U (U Side Mounting), Kit Type: Q (DeviceNetâ„¢, 16 Output Points), Option 1: CD2 (Exhaust Cleaner for Rc1 1/2: D Side Exhaust), Option 2: W (Dust Poof IP65 Rated)
Configuration: 1 (2 Position Single), Sealant: 0 (Metal Seal), Function: Standard (1W), Coil Voltage: 5 (24VDC), Light & Surge Suppressor: w/Light and Surge Suppressor, Manual Override: Non-locking Push Style, 1: 1, Porting Specification: Side Ported, Port Size: 03 (3/8), Thread: F (G)
Actuation Type: 1 (2 Position Single), Sealant: 0 (Metal Seal), Function: Standard (1W), Voltage: 5 (24VDC), Light & Surge Suppressor: w/Light and Surge Suppressor, Manual Override: B (Locking Slotted Style), Protection: Dust Proof, 1: 1, Piping Specification: B (Bottom Ported), Port Size: 03 (3/8), Thread: T (NPTF)
Actuation Type: 4 (3 Position Exhaust Center), Sealant: 1 (Rubber Seal), Function: Standard (1W), Voltage: 5 (24VDC), Light & Surge Suppressor: w/Light and Surge Suppressor, Manual Override: Non-locking Push Style, Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 03 (3/8), Thread: N (NPT)
Actuation Type: 1 (2 Position Single), Sealant: 0 (Metal Seal), Function: Standard (1W), Voltage: 5 (24VDC), Lead Wire: H (Grommet Lead Wire 1.5m), Light & Surge Suppressor: Yes, Manual Override: Non-locking Push Style, Protection: Dust Proof, 1: 1, Piping Specification: Side Ported, Port Size: 03 (Rc3/8)
Actuation Type: 2 (2 Position Double), Sealant: 1 (Rubber Seal), Function: Standard (1W), Voltage: 5 (24VDC), Light & Surge Suppressor: w/Light and Surge Suppressor, Manual Override: Non-locking Push Style, Protection: W (Dust Poof IP65 Rated), 1: 1, Piping Specification: Side Ported, Port Size: 03 (3/8), Thread: T (NPTF)
Thread sizes range from M3 to 2 and are available in both inch (NPT) and metric R/Rc(PT) Speed controller standard in-line style; Body sizes: M3, M5, 1/8, 1/4, 3/8, 1/2; Port sizes: M3, M5, 01, 02, 03, 04
.) ; Port size: 01 (1/8), 02 (1/4), 03 (3/8), 04 (1/2); Pilot port thread: Rc, NPT
Function: 1 (2 Position Single), Body Option: 1 (Base Mounted Non Plug-in), Direct Manual Override: 1 (Direct Manual Override), Pilot: Internal Pilot, Voltage: 5 (24VDC), Lead Wire: D (DIN Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style (Flush), Piping: B (Bottom Ported), Port Size: 03 (Sub-plate Plug-in Terminal 3/8, Non-plug-in Standard
Stations: 03 (3 Stations), Systems, Port Combinations: A [Ejector System, ø8 (Common PV)], Exhaust: 1 (Complex Exhaust), SI unit prefix: S6 (EX600 SI Unit), SI Unit: EB (EX600, EtherNet/IPâ„¢, IO-Link Unit), EX600 Output Polority, End Plate Type: 2 (Positive Common, B-coded M12 connector), EX600, I/O Unit Stations: 1 (1 Station), Option: C (with DIN rail mounting bracket for EX600)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: 1 (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: None; Temperature Sensor: None), Lead Wire: N (w/o Lead Wire and M8 Connector), Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None, Calibration
AS: AS, Size: 1 (M5 Basis), Style 1: 3 (Universal), Control Type: 1 (Meter-in), Thread: M5, 10-32UNF, R, Port Size: U10/32UNF, Tube Size: 03 (5/32"), Option: None, Lock Nut: J (Round)
Body Size: 1 (M5 x 0.8, 10-32UNF), Type: 2 (Elbow), Control Type: 1 (Meter-in), Indicator Direction: 1 (180°), Thread: R, Port Size: U10/32 (U10-32UNF), Width Across Flats: E (8mm), Tubing: 03 (ø5/32")
Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, threaded type valve , Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.) , Normally closed (N.C.) , Port size: 01 (1/8), 02 (1/4), 03 (3/8), 04 (1/2), Pilot port thread: Rc, NPT HIGH PURITY CHEMICAL VALVE, HAND OPERATE.
Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, threaded type valve , Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.) , Normally closed (N.C.) , Port size: 01 (1/8), 02 (1/4), 03 (3/8), 04 (1/2), Pilot port thread: Rc, NPT HIGH PURITY CHEMICAL VALVE, HAND OPERATE.
Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, threaded type valve , Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.) , Normally closed (N.C.) , Port size: 01 (1/8), 02 (1/4), 03 (3/8), 04 (1/2), Pilot port thread: Rc, NPT HIGH PURITY CHEMICAL VALVE, HAND OPERATE.