Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, threaded type valve , Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.) , Normally closed (N.C.) , Port size: 01 (1/8), 02 (1/4), 03 (3/8), 04 (1/2), Pilot port thread: Rc, NPT HIGH PURITY CHEMICAL VALVE, HAND OPERATE.
Model: LVH40 (Body Class 4, N.C.), Lever Operation: Non-locking, Self-reset, Port Size: 04 (1/2), Pilot Port Thread: N (NPT), Material: A (Body: SUS, Actuator Section: PP, Diaphragm: PTFE)
Size: 4 (40), Valve Type: 2 (Normally Open), Body Material: C (Brass), Seal Material: N (NBR), Port Size: 04 (Thread; 1/2), Thread Type: N (NPT), Rated Voltage: 5 (24 VDC), Electrical Entry: DS (DIN Terminal, w/Surge Voltage Suppressor)
Size: 4 (40), Body Material: S (Stainless Steel), Seal Material: E (EPDM), Port Size: 04 (1/2), Thread Type: N (NPT), Rated Voltage: 5 (24 VDC), Electrical Entry: WN (M12 Connector w/o Connector Cable, w/Surge Voltage Suppressor)
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: JT (OUT1: Analogue 1 to 5 V - OUT2: Analogue 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket
Rated Flow Range: 04 (0.5 to 4L/min), Flow Adjustment Valve: None, Thread: Rc, Port Size: 03 (3/8), Output Specification: 1 (OUT1: Analog 1 to 5V), Temperature Sensor: None, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °C, Bracket: R (Bracket), Calibration Certificate: None, Made to Order: X109 (EPDM Seal Material)
Base Mounted Wiring: 10 (Non Plug-in Individual Lead Wire Entry), Stations: 5 Stations, Passage: 1 (P: Common, EA,EB: Common, Port A,B: Side), Port Size: 04 (1/2), Thread: N (NPT)
Flow Rate Range: 501 (5 to 500 L/min), Thread Type: F (G), Port Size: 04 (1/2), Output Specifications: F (PNP; Analog 4 to 20 mA), Option 1: w/Lead Wire w/Connector, Unit Specifications: Unit Selection Function, Option 2: R (With Bracket), Calibration Certificate: A (With Calibration Certificate)
Valve; Stop Valve: None), Supply/Return Port Size: 04 (1/2), Return Unit Flow Switch Output Specifications: BT (Out 1: PNP; Out 2: Flow Rate: PNP; Temp.: PNP; Temperature Sensor: Yes), Lead Wire: N (w/o Lead Wire and M8 Connector), Return Unit Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)
Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 04 [Vacuum: 2 x Rc1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector),
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: N (NPT), Port Size: 03 (3/8), Output Specification/Temperature Sensor: JT (OUT1: Analogue 1 to 5 V - OUT2: Analogue 1 to 5 V; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: M (Instantaneous Flow: L/min, Accumulated Flow: L,Temperature: °C), Bracket
Rated Flow Range: 04 (0.5 to 4 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: 1 (Out 1 Flow Rate: Analog 1 to 5 V; Out 2 Temperature: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: R (w/Bracket), Calibration
Series LVH is a manually operated valve, available in a threaded or integral fitting type.Manually operated, threaded type valve , Body class: 2 (ø4 orifice dia.), 3 (ø8 orifice dia.), 4 (ø10 orifice dia.) , Normally closed (N.C.) , Port size: 01 (1/8), 02 (1/4), 03 (3/8), 04 (1/2), Pilot port thread: Rc, NPT HIGH PURITY CHEMICAL VALVE, HAND OPERATE.
Laterial vacuum entry without buffer series, Pad diameter: 02, 04, 06, 08, 10, 13, 16, 20, 25, 32, 40, 50 (mm), Pad style: flat, flat w/ribs, deep, bellows, Material: NBR, silicon rubber, urethane rubber, flourine rubber, EPR, Rotating or non-rotating, Multiple vacuum entry/mounting thread diameters VACUUM PAD, ZP, ZP2, ZP3. VACUUM PAD WITH BUFFER. 24.70000 lb. M30.
Body Size: 40, Thread: Rc, Port Size: 04 (1/2), Option: G (Round Type Pressure Gauge w/Limit Indicator), Attachment: V (3-Port Valve for Residual Pressure Release; Mounting: AF+AR+V), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: Standard
Stations: 04 (Stations), Wiring: F (D-sub Connector), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: C (Complex Exhaust), Pressure Switch for Vacuum/Pressure Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs, with Unit Selection Function), Leadwire: Y (2m Switch/Sensor Only), Unit Options: without Option, 1st Nominal Nozzle Size: 1 (ø0.7), 1st Selection
Body Size: 450C [78SCFM (2,200l/Min)], Thread: N (NPT), Port Size: 04 (1/2), Accessory: B (Bracket), Auto Drain: D (N.O. Auto Drain), Rubber Material: F (Fluororubber)
Body Size: 450C [78SCFM (2,200l/Min)], Thread: N (NPT), Port Size: 04 (1/2), Accessory: None, Auto Drain: D (N.O. Auto Drain), Rubber Material: F (Fluororubber)
Body Size: 40, Thread: Rc, Port: 04 (1/2), Option: E [Square embedded type pressure gauge (with limit indicator)], Attachment: V (Residual Pressure Relief 3 Port Valve), Semi-Standard 1: 1 (Set Pressure: 0.02 to 0.2 MPa), Semi-Standard 2: Standard
Body Size: 40, Thread: N (NPT), Port: 04 (1/2), Option: CE (C + E), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Z (Name Plate, Caution Plate for Bowl, and Pressure Gauge: psi, °F)