Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: N (NPT)
Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: Standard, Voltage: 6 (12VDC), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: N (NPT)
Function: 1 (Normally Closed), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: T (Power Saver), Voltage: 5 (24VDC), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: T (NPTF)
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)1000 VAC for 1 minute between live parts and case50 M or more between live parts and case (at 500 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (Non-energized)100 m/s2 in X, Y, Z directions, 3 times each (Non-energized
Lube is used, install a strainer (filtration rate of 5 m) upstream with a metal seal solenoid valve, which is susceptible to dust. Float switch mounting position Mounting orientation is upward.
A filtration degree of 5 m or less should be selected. 2. Implement countermeasures by installing aftercooler or air dryer, or water separator, etc. The air including excess drain may result in a malfunction of valves and other pneumatic equipment. Implement countermeasures by installing after-cooler or air dryer, or water separator, etc.
Response t me 1.Zns ' Shock resistance 300 m/s'(reed swrtch) 1000 m/s'(solid state s',vitch) Flange & Auto Switch Mounting Brqcket Weights NCDRBIOWI0.15.20.30 Rotation Time Setting Fitting Loeation And. Rotation Of Auto Switch luto Swilch 9(r, 160' Ewn a small torque generated by the rotary actuator. due to inertia, can cause qamage.
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A1 (Bracket A, Vertical Mounting)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)
Function: 2 (2 Position Double), Piping: 2 (Body Ported), Exhaust: 0 (Individual), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: None, Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8)
Function: 1 (2 Position Single), Piping: 3 (Body Ported), Exhaust: 3 (Common), Low Wattage: None, Pressure Specification: K (High-pressure, 1MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: M (M Plug Connector w/Lead Wire 300mm), Light/Surge Suppressor: Z (With light/surge voltage suppressor), Manual Override: Non-locking Push Type, A, B Port Size: 01 (1/8), Thread: N (NPT
Type of Actuation: 1 (2 Position Single), Manifold Type: 40 (Base Mounted Non Plug-in Single/Stacking Base, Plug-in Stacking Base), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: M (M Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: R (Surge Suppressor Non-polar), Manual Override: Non-locking Push Style, A, B Port Size: 01
.: AN101-01 Option Bracket Part No.: VR51B EN574: 1996 + A1: 2008 Class: Type III A Standard Bottom mounting Note) In the case of using soft nylon or polyurethane tubing, use caution when the maximum operating pressure of the tubing is used.
Type of Actuation: 2 (2 Position Double), Manifold Type: 20 (Body Ported Plug-in Integrated), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: M (M Plug Connector w/Lead Wire 0.3m), Lead Wire Length: None, Surge Suppressor: S (Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 01 (Body Ported 1/8)
Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: M (SI Unit Only), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire)
Function: 1 (Normally Closed), Piping: 4 (Base Mounted), Body Option: Individual EXH, Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: M (M Plug Connector w/Lead Wire 0.3m), Surge Suppressor: U (Surge Suppressor w/Light Non-polar), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8), Thread: N (NPT), Bracket: None, CE-Compliant: Q (CE-Compliant)
5S/cm () CE 085050 9 No.LFE*-OMY0008 * ON 5 /23% 3 OFF 2459 LCD / * 10 No.LFE*-OMY0008 LFE LFE LFE LFE 1 0.5 20L/min L/min 2 2.5100L/min 1 L/min 3 5200L/min 2 L/min 3 L/min 4 gal/min OUT1 OUT2 5 gal/min A NPN NPN 6 gal/min B PNP PNP 7 gal/min C NPN 1-5V SI 4567 D NPN 4-20mA Rc 1 2 3 N NPT 3 3/8 F G 4 1/2 6 3/4 8 1 11 No.LFE*-OMY0008 M12 M12 / / / / M12 LFE-1-A3 3 m
Function: 2 (Normally Open), Piping: 2 (Body Ported), Body Option: M (Common EXH), Specifications: Standard, Voltage: 5 (24VDC), Lead Wire: MO (M Plug w/o Connector), Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, Port Size: 01 (Base Mounted w/Sub-plate 1/8, Body Ported 1/8), Thread: F (G), Bracket: None, CE-Compliant: Q (CE-Compliant)