Body Size: 40, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: G (For Sizes 20, 25, 30, 40: Round Pressure Gauge w/Limit Indicator; For Size 10 Round Pressure Gauge w/o Limit Indicator), Semi-Standard: 1RY (1 + R + Y)
Body Size: 30, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: G (For Sizes 20, 25, 30, 40: Round Pressure Gauge w/Limit Indicator; For Size 10 Round Pressure Gauge w/o Limit Indicator), Semi-Standard: Y (Knob, Upward)
Stations: 03 (3 Stations), Piping: B (U Side: Open; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: W (w/Flow Adj.
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: 2T (Out 1: Analog 4 to 20 mA; Out 2: Flow Rate: None; Temp.: Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: L (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: S (w/Flow Adjustment Valve), Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: 2 (Out 1 Flow Rate: Analog 4 to 20 mA; Out 2 Temperature: None; Temperature Sensor: None), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min, Temperature: °C, Bracket: None, Calibration
Body Size: 40, Thread: Rc (Rc: for Sizes 20~60; M5: for Size 10), Port Size: 03 (3/8), Mounting: None, Semi-Standard, Body Size 10: Standard, Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: 8 (Metal Bowl w/Level Gauge)
Valve; w/Stop Valve), Supply/Return Port Size: 03 (3/8), Return Unit Flow Switch Output Specifications: FT (Out 1: PNP; Out 2: Flow Rate: Analog 4 to 20 mA ⇔ Analog 4 to 20 mA; Temperature Sensor: Yes), Lead Wire: w/Lead Wire and M8 Connector, 3 m, Return Unit Flow Switch Unit Specifications: J (Integrated Display: L/min; Accumulated Flow: L; Temp.: °F)
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: L (Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C), Bracket
Rated Flow Range: 20 (2 to 16 L/min), Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 03 (3/8), Output Specification/Temperature Sensor: L2 (Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: None), Lead Wire: Q (w/M12 -M8 Conversion Lead Wire, 0.1 m), Unit Specification: M (Instantaneous Flow: L/min; Accumulated Flow: L; Temperature
Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: BG (B + G), Semi-Standard 1: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 25, 30, 40), Semi-Standard 2: Standard
Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: B (Assembly of a Bracket and Set Nuts), Semi-Standard 1: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 25, 30, 40), Semi-Standard 2: Standard
Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: 2 (Metal Bowl), Semi-Standard 2: R (Flow Direction: Right to Left)
Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: 8J (8 + J), Semi-Standard 2: Standard
Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: N (Non-Relieving Exhaust Mechanism), Semi-Standard 2: Standard
Body Size: 30, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: H (Set Nut for Panel Mount), Semi-Standard 1: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 25, 30, 40), Semi-Standard 2: Standard
Body Size: 30, Thread: N (NPT), Port Size: 03 (3/8), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 25, 30, 40), Semi-Standard 2: Z (NPT Porting requires Z, Name Plate, Caution Plate for Bowl, & Pressure Gauge in Imperial
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: 1 (0.02 to 0.2MPa Setting), Semi-Standard 2: Standard
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: G (For Sizes 10, 20, 30, 40 Round Type Pressure Gauge w/Limit Indicator; For For Size 10: Round Type Pressure Gauge w/o Limit Indicator ), Semi-Standard 1: Standard, Semi-Standard 2: R (Flow Direction: Right to Left)
Body Size: 40, Thread: Rc: Size 20, 25, 30, 40; M5: Size 10, Port Size: 03 (3/8), Option: Standard, Semi-Standard 1: J (Drain Guide 1/8: Size 20; Drain Guide 1/4: Sizes 25, 30, 40), Semi-Standard 2: Standard