SMC Corporation of America
Elite Part Number Search
Search Results "ZM051H-B5L-E14C-L-Q"

Body Size: 6 (1), Valve Option: for General, Port Size: 12 [1 1/4 (32A)], Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Light/Surge Suppressor: L (Indicator Light), Actuation Type: A (N.C., Normally Closed), Pilot: Standard (Internal Pilot), Thread: N (NPT), CE Compliant: Q (CE Compliant)

Rated Flow Range: 25 (0.3 to 25 L/min), Flow Adjustment Valve: None (Straight), Port Size: N7 (1/4), Output Specification: L2 (Out 1: IO-Link or NPN/PNP, Out 2: NPN, PNP, or Input), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m)

Rated Flow Range: 01 (10 to 1000 l/min), Output Specifications: L2 [Out1: IO-Link, Switch Output (N/P); Out2: Switch Output (N/P)], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m), Unit Specification: M (SI Unit Only)

Rated Flow Range: 11 (1 to 100 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N2 (NPT1/4), Output Specification: L4 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 4 to 20 mA), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: V (Panel Mount Adapter, w/Flow Adjustment Valve

Valve: None; Stop Valve: None, Return Unit Flow Switch: 7 (Integrated Display), Return Unit Flow Range: 20 (2 to 16 L/min), Return Unit Components: Flow Adj.

Rated Control Flow Range: 10 (0.1 to 10 L/min), Port Size: F1 (G1/8), Input/Output Specification: 1 (Input: Analog 1 to 5 V, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 1 to 5V or 0 to 10V), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: Unit Specification, Bracket: R (Bracket (mounting position: Side), Operation Manual/Calibration Certificate

Rated Control Flow Range: 11 (1 to 100 L/min), Port Size: N7 (1/4 inch), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: M (SI units only), Bracket: R (Bracket (mounting position: Side)

Rated Control Flow Range: 11 (1 to 100 L/min), Port Size: N2 (1/4 NPT), Input/Output Specification: 2 (Input: Analog 4 to 20mA, Output 1:IO-Link/NPN/PNP, Output 2: Analog Output 4 to 20mA), Wire Connector: Q (M12-M12 lead wire with connector (3 m/5 core)), Unit Specification: M (SI units only), Bracket: R (Bracket (mounting position: Side), Operation Manual/Calibration Certificate: K (with

Rated Flow Range: 50 (0.5 to 50 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N7 (1/4), Output Specification: L4 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 4 to 20 mA), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: M (SI Unit Only)

Stations: 02 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: Q (Vacuum Pump System), Pressure Switch for Vacuum/Pressure Sensor: N (w/o Pressure Switch for Vacuum/Pressure Sensor), Leadwire: without Leadwire, Unit Options: without Option, 1st Nominal Nozzle Size: 0 (for Vacuum Pump System), 1st Selection Supply Valve and Release

Stations: 04 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: Q (Vacuum Pump System), Pressure Switch for Vacuum/Pressure Sensor: N (w/o Pressure Switch for Vacuum/Pressure Sensor), Leadwire: without Leadwire, Unit Options: without Option, 1st Nominal Nozzle Size: 0 (for Vacuum Pump System), 1st Selection Supply Valve and Release

Stations: 02 (Stations), Wiring: L (Individual Wiring or None), Manifold Options: B (with DIN Rail Mounting Bracket), Exhaust: Q (Vacuum Pump System), Pressure Switch for Vacuum/Pressure Sensor: N (w/o Pressure Switch for Vacuum/Pressure Sensor), Leadwire: without Leadwire, Unit Options: K (Vacuum Break Flow Adjusting Needle, Screwdriver Operation Type), 1st Nominal Nozzle Size: 0 (for Vacuum

Classification of Waterproof: 1 (Drip Proof/Rain Proof), Set Flow: 0 (14 to 60 l/min), Thread: Rc(PT), Port Size: 06 (3/4), Fluid Contact Area Material: 0 (Copper Alloy), Seal Material: 1 (FPM), CE-compliant: Q (CE-compliant)

Rated Flow Range: 12 (120 to 12000 l/min), Thread Type: N (NPT), Port Size: 20 (2), Output Specification: L4 [Out: IO-Link, Switch Output (N/P); Func: Analog Current Output <-> External Input; Monitor Unit Model: PFG310 Series], Lead Wire: Q (Lead Wire and M12-M12 Connector, 3m), Unit Specification: M (SI Unit Only)

Classification of Waterproof: 2 (Jet Proof/Splash Proof), Set Flow: 1 (20 to 1500 l/min), Thread: N (NPT), Port Size: 10 (1), Fluid Contact Area Material: 1 (SUS304), Seal Material: 1 (FPM), CE-compliant: Q (CE-compliant)

Bore: 80mm, Port Thread: Rc, Piping: Flange Side, Stroke: 40mm, Action: B (Double Acting Spring Type), Roller Material: M (Carbon Steel), Option: None, Port and Lever Position: Q (180° Clockwise), Auto Switch: M9N--Solid State, Gen. Purpose, 3 Wire NPN, Horizontal, Leadwire or Prewired Connector: L (3m)

Series: 3 (VQZ300), Composite Symbol: 1 (Metal Seal N.C.), Function: BR (B + R), Coil Voltage: 5 (24VDC), Lead Wire: LO (L Plug w/o Connector), Manual Override: Non-locking Push Style, IP65 Compliant: None, 1: 1, Port Size: w/o Sub-plate, CE Compliant: Q (CE Marked)

Rated Flow Range: 10 (0.1 to 10 L/min), Flow Adjustment Valve: S (With Flow Adjustment Valve, Straight), Port Size: N1 (NPT1/8), Output Specification: L4 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 4 to 20 mA), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: S (Bracket, w/Flow Adjustment Valve)

Valve; w/Stop Valve), Return Unit Flow Switch: 5 (Remote Sensor Unit), Return Unit Flow Range: 04 (0.5 to 4 L/min), Return Unit Components: P (w/o Flow Adj.

Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: None (Straight), Port Size: C4 (ø4), Output Specification: L4 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 4 to 20 mA), Lead Wire: Q (w/M12 Conversion Lead Wire and Connector, 0.1m), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve)