Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)], Piping Direction: -, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: NPN Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: -, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Rc1/8, Piping Direction: -, Lead Wire: -, Bracket: -, Operation Manual: -
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)]
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C01 (Rc1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: X (NPN Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: A2 [URJ1/4 (Face Seal Fitting)]
Rated Vacuum Range: -101 to 0 kPa, Output Specification: R (NPN Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 02 [R1/4, (M5, Female Threaded)]
Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C01 (Rc1/8)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: F02 [G1/4, (M5, Female Threaded)]
D-A90(V)/D-A93(V)/D-A96(V) Direct Mounting Style .
W W W Dynamic Moment Moment generated by the load equivalent to impact at the stroke end Guide central axis We = WV V = 1.4 Va Average load coefficient Pitch moment Me1 = 1/3. We L Yaw moment Me3 = 1/3.
V V V -XC47 to -XC58 -XC59 to -XC61 Change of port location V V V V V V V V 30 to 100 S,W,Y* V S,W,Y* S,W,Y* S,W,Y* S,W,Y* -XC59 to -XC61 -XC63 One side air-hydro, One side air V V V V V V V V 50, 63, 80, 100 V V V V -XC64 One side air-hydro, One side air V V V V V V V V V V V V * -XC8 to -XC11 and -XC31 to -XC36 do not include the angle adjustable type. * -XC37 to -XC46 and -XC47
(Port size) e Port size (OUT q) OUT w OUT w IN IN OUT OUT Body type Nil Standard*1 V V V V V Semi-standard r 1 Front and back port selectable type*2 V V V V OUT w OUT w *1 The front and back ports are for releasing pressure and only come in size 1/8, irrespective of the e port size.
200 W, J 5 V, 12 V D3-wire (PNP) M9PV M9P V V V v v 2-wire 12V M9BV M9B V V V v v Solid state auto switch XC6 Change rotation range between 0 and 110 W, J Grommet Yes For 20, 30, 40 3-wire (NPN) 5V, 12 V S79 V V v v IC circuit 3-wire (PNP) S7P V V v v Oilproof heavyduty cord Relay, PLC XC7 Reversed shaft W, J 2-wire 12 V T79 V V v v Connector T79C V V V V 24 V Grommet Yes
Standard equipped with shock absorber -X 75 100 125 150 200 250 300 20 25 32 40 50 63 80 100 20 25 32 40 50 20Series MGC P . 8-21-6 Data Series MGG V V V V V V V V V V V V V V Guide Cylinder Guide Table Cylinder with Turntable Series MGC Long stroke Bore size (mm) Standard stroke (mm) Compact type of series MGG Lightweight, space-saving 250 300 350 400 450 500 600 700 800 900 1000 1100 1200
LEFS v v E339743 v v v v 11-LEFS v v E339743 v v v v 25A-LEFS v v E339743 v v v v LEFB v v E339743 v v v v LEJS v v E339743 v v v v 11-LEJS v v E339743 v v v v 25A-LEJS v v E339743 v v v v LEJB v v E339743 v v v v LEY25/32/63 v v E339743 v v v v LEY100 v LEYG v v E339743 v v v v LESYH v v AC servo motor Compatible
4.5V or Less 4.5V or Less Leakage Current 1 0 A o r L e s s a t 2 4 V D C 1 m A o r L e s s a t 2 4 V D C Indicator Lamp O N : R e d L i g h t e m i t t i n g d i o d e Note: Pre-wired Switches with 3/4 Pin Connectors available H O W T O O R D E R S E R I E S M H R M 10 R D HR S Y M B O L S N O O F S W I T C H E S . . . . . .2 Pieces S . . . . .1 Piece Auto Switch .Standard D . . . .W/Magnet