-/22-CA240 11-/22-CA250 11-/22-CA263 Relief type 50, 75, 100, 125, 3/8 Non-lube Double acting, single rod Air cushion Available 150, 200, 250, 300, 1/4 Vacuum suction type 350, 400, 450, 500 3/8 Note) Consult SMC for long stroke.

M L1 L2 1 4 8 6 DEF06-02 48 20 11 16 16 50.5 46.5 17 15 13 11 19 17 14 12 14 12 6max. 4max. 3 8 DEF08-03 66 3 8 3 8 DEF10-03 10 12 53.5 89 DEF12-03 54.5 34 51 17 17 17 17 15 17 19 19 104 17 19 17 19 7max. 7max. 105 Series H, DL, L, LL Self-align Fittings Plug: DP Applicable tube O.D. Weight (g) Part No.

M L K J H E t W1 W2 M 14 20 25 29 37 49 58 69 89 100 117 136 14.5 20.5 24.5 30.5 36.5 48.5 6 7 7 9 9 10 11 16 21 24 32 41 10 17 22.5 24.5 27 30 16 21 26 32 41 50 17 24 28 36 43 55 8 8 8 8 13 13 1/8" 1/4" 3/8" 1/2" 3/4" 1" LQ3P1A LQ3P2A LQ3P3A LQ3P4A LQ3P5A LQ3P6A 1/4 (E) (E) L Panel Aperture (K) Straight Union : LQ3U (mm) Inch Size H Model Tubing O.D.

Dimensions Model Metric size D2 D1 H1 H2 H3 H4 H5 L1 L2 L3 Inch size TMH-05 21 8.3 8.5 15.4 7.7 9.3 6.4 6.3 3.3 11.7 TMH-06 13.1 TMH-07 26.5 10.6 11 20 10 11 7.2 7.1 4.3 13.5 10 TMH-08 TMH-09 15.5 TMH-10 18.5 34 14.6 14.2 28 14 14 9.6 9.5 4.3 TMH-11 18.8 5

Piping 10 7.1 Piping connections to the PD Ports 10 7.2 Piping connections to the Supply (P) port 11 8. Construction 12 9. Dimensions 15 10.

Load voltage Lead wire length (m) Indicator light Auto switch model Wiring (Output) Pre-wire connector Special function Type Electrical entry Applicable load 0.5 (Nil) 3 (L) 5 (Z) AC DC Perpendicular In-line 97 Relay, PLC Reed switch Grommet 12 V 24 V 2-wire Yes 93A 100 V Auto switch cannot be mounted on the clevis style or trunnion style.

Load voltage Lead wire length (m) Indicator light Auto switch model Wiring (Output) Pre-wire connector Special function Type Electrical entry Applicable load 0.5 (Nil) 3 (L) 5 (Z) AC DC Perpendicular In-line 97 Relay, PLC Reed switch Grommet 12 V 24 V 2-wire Yes 93A 100 V Auto switch cannot be mounted on the clevis style or trunnion style.

OFF Bus OUT side: No Link, No Activity Settings1 Settings2 Green ON Bus OUT side: Link, No Activity (100 Mbps) IP address setting switch Bus OUT side: Link, Activity (100 Mbps) Green flashing L/A OUT Mounting and Installation Settings1 Settings2 Yellow ON Bus OUT side: Link, No Activity (10 Mbps) Do not operate in an atmosphere containing flammable or explosive gases.

Select "Options" "TP/ITP 100 Mbps full duplex"and check "Disable autonegotiation". -23No.EX-OMO0030-E Configuration of the EX260-SPN to enable the FSU function Select the EX260-SPN icon from the dialogue of the HW configuration window. Double click the Slot X1 Interface and in the "General" window check "Prioritized startup".

40 6.6 6 42 93 32 59.5 37.5 10 12 138 154 34 50 9 9 48 112 40 66 44 10 12 146 162 40 60 9 9 54 120 50 72 44 12 16 178 198 46 65 11 10 64 148 63 77 49 12 16 192 212 58 75 11 10 78 162 80 96.5 56.5 16 24 238 262 54 90 13.5 16 91.5 202 100 116 66 19 31 280 308 62 100 15.5 22 111.5 240 Caution Do not use this cylinder as a stopper.

V Relay, PLC 2-wire 24 V No 5 V,12 V 100 V or less Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water resistance.

Refer to VCW for model numbers and characteristics. 17-2-11 6 Series VCA Construction q w e r t Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Component Parts No.

Rc NPT G Nil N F OUT(2) 1 IN(1) Port size Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Class 4 Symbol 01 02 03 04 06 Voltage 1 2 3 4 36 100 VAC 200 VAC 110 VAC 220 VAC 230 VAC Orifice size Please consult with SMC regarding other voltages.

Flow (SCFM) Supply pressure 100 psig Secondary pressure 30 psig Flow rate .7 SCFM Pressure Characteristics Mounting/Adjustment 2) On the NARM3000, pull the adjustment handle to release the lock. (An orange colored line is provided at the bottom of the adjustment handle for visual checking.) Push the adjustment handle to engage the lock.

SI unit only Note 9) With unit switching function [Initial value psi] Note 8) 14.5 to 14.5 (100 to 100) With unit switching function Note 8) PNP 2 outputs SI unit only Note 9) E/F: Vacuum pressure switch With unit switching function [Initial value psi] Note 8) Note 7) Only the lead wire length 118 inch (3 m) is available for the pressure sensor.

200 100 200 25 50 11 22 Outlet air atmospheric pressure dew point oC -15 -20 *Note2 Inlet air flow rate L/min(ANR) Outlet air flow rate L/min(ANR) Standard Performance conditions Purge air flow rate L/min(ANR) Inlet air pressure MPa *Note3 0.7 25 Inlet air temperature oC Inlet air saturation temperature oC 25 Dew point indicator purge air flow rate 1 L/min (ANR) {In the case of inlet air

Transmission rate [kbps] 9.6 19.2 45.45 93.75 187.5 500 1500 3000 6000 12000 Lower-level bus Core cross-section 0.34mm2 or more Wire diameter 0.64mm or more 10 11 The wirings are described in the following order.

200 300 400 500 600 0 100 200 300 400 500 600 0 100 200 300 400 500 600 Flow rate l/min (ANR) Flow rate l/min (ANR) Flow rate l/min (ANR) Pressure Characteristics Conditions: Upstream pressure 0.7MPa Downstream pressure 0.2MPa Flow rate Q = 20l/min (ANR) 0.30 Downstream pressure MPa 0.25 Starting point 0.20 0.15 0.10 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Upstream pressure MPa Construction ARJ310