1 to 30 psig (0.007 to 0.2 MPa) 1 to 60 psig (0.007 to 0.4 MPa) 2 to 100 psig (0.014 to 0.7 MPa) Bonnet option 02 06 10 Bonnet Standard Panel installation 4) Code No code P Connections (Inletq, Outletw) 4) Panel mounting hole: dia. 1.56 inch (39.6 mm).
0 1 Standard Micro load Port size Nil 02 N02 With gasket Rc 1/4 NPT 1/4 16-9-3 2 Series IS3000 Construction Precautions IS3000-02/3010-02 (Rc 1/4 thread) Be sure to read before handling.
Model Pressure range *1 Indication unit Connection thread Note MPa Port size 01 Rc1/8 02 Rc1/4 R1/8 R1/4 G46-7-02-SRB 0 to 0.7 R1/4 G46-10-02-SRB 0 to 1.0 G46-4-01 to 02-SRB 0 to 0.4 MPa Set pressure range: 0.05 to 0.69 MPa 02 WR110 X215 *1: Do not apply more pressure than the max. pressure displayed. It may cause a malfunction.
Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.
Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.
Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.
Request message to read (from master) 02 30 31 52 50 56 31 03 65 Request to read Address BCC data End code Identification code Start code Response message from the product 02 30 31 06 50 56 31 30 30 32 35 30 03 06 Address Start code BCC data Affirmation code End code Numerical data Identification code Code Symbol/Data ASCII code Start code STX 02H Address 01 30H 31H Required content R
Request message to read (from master) 02 30 31 52 50 56 31 03 65 Address BCC data End code Request to read Start code Identification code Response message from the product 02 30 31 06 50 56 31 30 30 32 35 30 03 06 Address BCC data End code Start code Numerical data Affirmation code Identification code Code Symbol/Data ASCII code Start code STX 02H Address 01 30H 31H Required content R
For the manifold specifications and precautions, refer to Best Pneumatics Vol. 4. 02 1 4 Individual exhaust To order valves and blanking plate assembly mounted onto the manifold, list valves and blanking plate assembly with manifold base part number.
Rc 1/8 Body side VZA414-1P-01 VZA414-1P-02 VZA414-2P-01 VZA414-2P-02 VZA424-1P-01 VZA424-1P-02 VZA424-2P-01 VZA424-2P-02 Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 Rc 1/8 Rc 1/4 M5 x 0.8 0.49 0.11 2.2 0.57 0.19 2.4 N.C. Sub-plate side M5 x 0.8 0.49 0.11 2.2 0.57 0.19 2.4 N.C. Body side M5 x 0.8 0.45 0.32 1.9 0.57 0.19 2.4 N.O. Sub-plate side M5 x 0.8 0.45 0.32 1.9 0.57 0.19 2.4 N.O.
Type 40 Applicable solenoid valve SYJ514-SYJ514M-SYJ524-SYJ524M-How to Order SS3YJ5--40-05 -M5 R port 1/8 P port 1/8 P, R port thread type Stations A port size 02 : 20 2 stations : 20 stations Applicable blanking plate assembly SYJ500-10-3A Nil A A Rc G NPT NPTF M5 01 M5 x 0.8 1/8 F N T A port M5 x 0.8, 1/8 Note) For more than 9 stations, supply air to both sides of P port and exhaust air
For 3 stations For remote I/O A1W DeviceNet PROFIBUS-DP CC-Link 16 For 16 stations A2W 0 Without SI unit Stations Ports 1, 3, 5 position Symbol 02 Stations 2 stations Note U D B U side (2 to 10 stations) D side (2 to 10 stations) Both sides (2 to 16 stations) Note 1) Double wiring specifications 08 02 8 stations 2 stations Note 2) Supply/Exhaust block assembly specification Specified
Note) Available for the rubber seal type only. 25 Manifold Specification Sheet Series VQC4000: Base-Mounted Type/Plug-in Unit How to order manifolds VV5QC 4 1 08 TD0 02 T Kit 1 2 3 7 VV5QC 4 1 16 SDQW 02 S Kit Series VQC4000 4 5 6 Base-Mounted plug-in Stations Electrical entry Options 01 1 station Nil None Special wiring specifications Note 1) (except for double wiring) D-side entry Kit
-L2 0x0013 (19) 0 R ID ISE70-02-L2 0x0014 (20) 0 R Pressure sensor 8 0x0015 (21) 0 R No.
-L2 0x0013 (19) 0 R ID ISE70G-02-L2 0x0014 (20) 0 R Pressure sensor 8 0x0015 (21) 0 R No.
SI unit for SV series valves ( EX500-S 01 ) ( EX500-Q 02 ) PWR PWR COM COM 64.4 80.3 64.4 28 66 84.8 79.4 68.5 80.3 series 54.5 60 60 43.2 43 43.2 22.2 22 22.2 13 10.5 28.6 44 0 1 36 10.5 1 0 22 23 The mounting and removing methods of SI unit are as shown below.
For the IR200-02□□: IR2000-02□□-A
For the IR201-02□□: IR2010-02□□-A
For the IR202-02□□: IR2020-02□□-A
Note) Select option “H” when panel mounting the product.
The panel mounting hole dimensions are the same for old IR200 and IR2000-A series regulators.
.· Y210-□01-A, 02-A applicable models: AC20-A, AC20B-A, AC20C-A.· Y310-□01-A, 02-A applicable models: AC25-A, AC25B-A, AC25C-A · Y310-□01-A, 02-A applicable models: AC30-A, AC30B-A, AC30C-A.· Y410-□02-A, 03-A applicable models: AC40-A, AC40B-A, AC40C-A.· Y510-□02-A, 03-A applicable models: AC40-06-A, AC40B-06-A.· Y510-□02-A, 03-A applicable models: AC40C-06-A.
Tap water: Standard of The Japan Refrigeration And Air Conditioning Industry Association (JRA GL-02-1994) 15% ethylene glycol aqueous solution: diluted by tap water in condition above without any additives such as antiseptics.