Auto switch operating range (mm) Auto switch model D-M9/D-M9W 12 16 20 25 32 40 50 63 3.5 5 5 5 6 6 6 6.5 7 9 9 9 9.5 9.5 9.5 11 D-A9 Values whitch include hysteresis are for guideline purposes only. They are not a guarantee (assuming approximately 30% dispersion) and may change substantially depending on the ambient environment. 14-5.
BBA4: D-C7/C8/H7 "D-H7BAL" switch is set on the cylinder with the screws above when shipped.
56.5 22 PF3W520S 60.5 22 PF3W540S 78 30 -44No.PF-OMN0009CN-F PF3W504/520/540(+) A AA D K S PF3W504S--T 115 50 81.2 69.5 67.5 PF3W520S--T 123 54 85.2 73.5 71.5 PF3W540S--T 153 71 105.5 90 89 -45No.PF-OMN0009CN-F PF3W511-U25/PF3W521-U30(PVC ) 2X A B D E F J K L N P Q 25 A 154 46 77 57.6 23 77 63 28 18 3.5 14 32 30 A 146 56 91 71.6 28.5 73 60.5 25 27.5 3.5 14 38 S T U V W Y Z 25 A 59
System construction status No.0 No.1 No.2 No.3 No.4 No.5 No.6 No.7 No.8 No.9 End EX600 EX600 EX600 EX600 EX600 -DX#D EX600 -DX#D EX600 -DX#D EX600 -DX#D EX600 -DX#D EX600 -SEN3 plate -LAB1 -LAB1 -LBB1 -LBB1 -127No.EX-OMX1011 (6) When unit diagnostics is generated, the diagnostic information is displayed on the [SYSTEM CONFIGURATION STATUS] screen.
width across flats) AS-D AS-T ASP ASN AQ ASV AK Metric Size Inch Size VCHC Model d T Weight (g) H D1 D2 L1 L2 L3 L5 (1) A (2) Model d T Weight (g) H D1 D2 L1 L2 L3 L5 (1) A (2) D3 L4 Max.
ms 50 ms 50 ms 50 ms 7 3-Color Display Digital Flow Switch Series PFMC Construction/Fluid Contact Parts i o !
Dimensions AS420 AS500 AS600 67.5 74 90 1/4, 3/8, 1/2 3/4 1 38 42 55 122 115 158 112 105 148 50 50 62 L1 L2 L4 Min.
Ejector mounting position U D U side D side [Example: When individual wiring type model 45 for SY3000 is selected] ZZY Y3-45-04D-C6J1U 1SET SY3000 manifold model Ejector valve number Note 1) The combined total of solenoid valve and ejector valve stations is a maximum of 20 stations. (Example: When there are 12 solenoid valve stations, there are 8 ejector stations.)
A to B C to D 500 L 5 to 500 -25 to 525 L/min 1000 L 10 to 1000 -50 to 1050 2000 L 20 to 2000 -100 to 2100 PFMC7 40 to 4000 -200 to 4200 500 L 0.17 to 17.66 -0.90 to 18.50 cfm 1000 L 0.35 to 35.31 -1.80 to 37.10 2000 L 0.70 to 70.63 -3.50 to 74.20 The flow ranges and relationship between the fluid and PD are shown in the figures below.
Configuration One thermo-chiller for one master. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Fig. 3-13 Connection of RS-232C HRS Series 3.3 Installation 3-25 HRX-OM-W032 Chapter 3 Transport and Setting Up 3.4 Piping Piping port size Connect piping firmly. Incorrect piping might cause leakage of supplied or drained fluid and wet surrounding area and facility.
/M5W/M5TL D-E7A/E80A 25 6 4 32 6 4 D-M5, D-M5W, D-M5TL D-E7A, D-E80A D10 15 5 10 1 pc. 2 pcs.
/M5W/M5TL D-E7A/E80A D-M5, D-M5W, D-M5TL D-E7A, D-E80A D10 15 5 10 1 pc. 2 pcs.
code, Plug, Straight 5 m, SPEEDCON compatible EX9-AC010EN-PSRJ Cable with M12 connector, D code-RJ45, Plug, Straight 1 m EX9-AC020EN-PSRJ Cable with M12 connector, D code-RJ45, Plug, Straight 2 m EX9-AC030EN-PSRJ Cable with M12 connector, D code-RJ45, Plug, Straight 3 m EX9-AC050EN-PSRJ Cable with M12 connector, D code-RJ45, Plug, Straight 5 m EX9-AC100EN-PSRJ Cable with M12 connector, D
Standard CE, UL/CSA, RoHS Analogue output Range Rated pressure range A B E For vacuum 0 to -101 kPa 0 -101 kPa 10.1 kPa For compound -100 kPa to 100 kPa -100 kPa 100 kPa For low pressure 0 to 100 kPa 0 100 kPa -10 kPa 0 to 1 MPa 0 1 MPa -0.1 MPa For positive pressure 0 to 500 kPa 0 500 kPa -50 kPa Range Rated pressure range C D F For low differential pressure 0 to 2 kPa 0 2 kPa -0.2 kPa
Heavy load Standard load Medium load Light load 1 10 50 100 200 1 0.25 0.49 0.98 1.96 2 20 2 0.49 75 200 400 0.74 1.47 2.94 3 30 3 0.74 100 300 600 0.98 1.96 3.92 4 40 125 400 800 4 0.98 1.23 2.45 4.90 5 50 5 1.23 150 500 1000 1.47 2.94 5.88 6 75 200 600 1200 6 1.47 1.96 3.92 7.84 7 100 250 700 1400 7 1.72 2.45 4.90 9.80 8 300 300 800 1600 8 1.96 2.94 5.88 11.76 9 500 500 900 1800 9 2.21
Adsorb error detection time setting (Unit: ms, Range: 50..5000ms) Set the time to continuously check the vacuum pressure level.
ANR)] Air consumption [L/min(ANR)] Vacuum pressure [kPa] Vacuum pressure [kPa] Vacuum pressure 80 Suction flow 60 40 20 Air consumption 0 0 10 20 40 50 60 30 Supply pressure [MPa] Suction flow [L/min(ANR)] ZHP-12 ZHP-12 (Supply pressure: 0.35 MPa) 100 90 80 70 60 50 40 30 20 10 0 0 0.1 0.2 0.3 0.4 0.5 0.6 100 100 90 80 70 60 50 40 30 20 10 0 Suction flow [L/min(ANR)] Air consumption [L/min
Parts cannot be shipped separately. 1937 Series VHS20/30/40/50 Dimensions VHS20/30 VHS40/40-06/50 10 I EXH. 10 G F H I SUP. E X H . F G H SMC P . U S C E Padlock mounting position D C Padlock mounting position D SUP. SUP A B A B IN OUT IN OUT 2 1 3 EXH. EXH.
60 Hz Description Code Specication ECC-PNAL-20MT-D, 28.8V DC 5.0 W ECC-PNAL-20MR-D, 28.8V DC 7.0 W ECC-PNAL-20MR-A, 264V AC~ 8.0 W ECC-PNAL-10MT-D, 28.8V DC 2.0 W ECC-PNAL-10MR-D, 28.8V DC 3.0 W ECC-PNAL-10MR-A, 264V AC~ 4.0 W ECC-PNAL-6MR-A, 264V AC~ 3.0 W 24 V DC < 7.0 Amp ECC-PNAL-***-D 5ms ECC-PNAL-***-D 24V DC, +20% -15% 4 PneuAlpha Hardware Specification 2 Table 2.2: Power Supply Specications
Electrical entry TT is approved for Class I, II, III, Division 1, Groups A, B, C, D, E, F, G. Electrical entry L and LL is approved for Class I, Division 1, Groups A, B, C, D. 4.