Series: LEFB, Size: 32, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: T (48mm), Stroke: 2000mm, Motor Option: w/o Option, Auto Switch Compatibility: None, Grease Application: N (w/o, Roller Specification), Positioning Pin Hole: K (Body Bottom 2 Locations), Actuator Cable Type, Length: R3 (3m), Controller: C91 (EtherNet/IPâ„¢), Mounting: 8 (DIN Rail)
Series: LEFB (Belt Drive), Size: 32, Motor: Step Motor (Servo 24 VDC), Lead: T, Stroke: 2000mm, Motor Option: w/o Lock, Auto Switch Mounting Bracket: None, Grease Application: N (w/o, Roller Specification), Positioning Pin Hole: K (Body Bottom, 2 Locations), Actuator Cable: R (Robotic Flexible Cable), Actuator Cable Length: 3 (3m), Controller Type - LEC, JXC: C91 (JXC91, EtherNet/IPâ„¢ Direct
Series: LEFS (Ball Screw Drive), Accuracy: Basic Type, Size: 16, Motor Mounting Position: In-line, Motor: Step Motor (Servo 24 VDC), Lead Screw: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 200mm, Motor Option: w/o Lock, Auto Switch Mounting Bracket: None, Grease Application: with, Positioning Pin Hole: K (Body Bottom, 2 Locations), Actuator Cable: R (Robotic Flexible
Series: LEFB, Size: 25, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: T (48mm), Stroke: 1000mm, Motor Option: w/o Option, Auto Switch Compatibility: None, Grease Application: With, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type, Length: R3 (3m), Controller: C91 (EtherNet/IPâ„¢), Mounting: 8 (DIN Rail)
Series: LEFB, Size: 16, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: T (48mm), Stroke: 1000mm, Motor Option: w/o Option, Auto Switch Compatibility: None, Grease Application: With, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type, Length: R3 (3m), Controller: C91 (EtherNet/IPâ„¢), Mounting: 8 (DIN Rail)
Series: LEFS, Accuracy: Basic Type, Size: 25, Motor Mounting Position: In-line, Motor Type: E (Battery-less absolute, 24VDC, Step), Lead: A (Size 16: 10mm, Size 25: 12mm, Size 32: 16mm, Size 40: 20mm), Stroke: 750mm, Motor Option: w/o Option, Auto Switch Compatibility: None, Grease Application: With, Positioning Pin Hole: Housing B Bottom, Actuator Cable Type, Length: R3 (3m), Controller:
Cylinder side pressure (P2) I N I N O UT O UT Specifications 0.8 MPa 0.15 MPa 5 to 50C 0.60 dm3/(sbar) 180 c.p.m Maximum operating pressure Minimum operating pressure Ambient and fluid temp.
Repeatability Note 4) 2% F.S. (0 to 50C, based on 25C) Temperature characteristics For measured value display: 4-digits, 7-segment LED (Orange) For channel display: 1-digit, 7-segment LED (Red) Display method Status LEDs Illuminates when output is ON OUT1: Red Enclosure Operating temperature range Operating humidity range IP65 for the front face only, the rest is IP40.
Operating: 0 to 50C, Stored: 10 to 60C (with no freezing and condensation) Resistance Operating or Stored: 35 to 85%RH (with no condensation) 10 to 500 Hz with a 1.5 mm amplitude or 98 m/s2 acceleration, in each X, Y, Z direction for 2 hrs., whichever is smaller.
Recommended lubricant [AL] Class 1 turbine oil (ISO VG32) Bowl material [AW/AL] Polycarbonate Bowl guard [AW/AL] Semi-standard (Steel) Standard (Polycarbonate) Construction [AW] Relieving type Weight [kg] 0.33 0.63 1.15 1.25 3.21 3.36 1 Pressure gauge connection threads are not available for F.R.L. unit with a square embedded type pressure gauge or with a digital pressure switch. 2 5 to 50C
. *2 5 to 50C for the products with the digital pressure switch *3 For the following conditions in accordance with [Test condition: ISO 8573-4:2001 compliant, Test method ISO 12500-3:2009 compliant] Conditions: When a new element is used, and the flow capacity, inlet pressure, and the amount of solid bodies on the filter inlet side are stable *4 The compressed air purity class is indicated
5 to 50C 5 to 50C 5 to 50C 5 to 50C 5 to 40C 5 to 40C 5 to 40C 5 to 40C Electric power 180VA 300VA 300VA 300VA 640VA 180VA 300VA 640VA 180VA 300VA 640VA 640VA Control system AC software servo/PTP control Position detection system Incremental encoder Home position return direction Maximum positioning point setting Can be selected between the motor side and the side opposite the motor. 1008
Note 3) Solenoid valve: Max. 50C Note 4) Synthesized effective area with 2 position.
: based on 25C) 2% F .S. or less (0 to 50C: based on 25C) 5% F.S. or less (0 to 60C) ZSE30: 0.2 F.S. 2 digits or less ISE30: 0.2 F.S. 1 digit or less Repeatability 1% F.S. or less 0.2% F.S. 1 digit or less 0.5% F.S. 0.2% F.S. 1 digit or less Hysteresis mode: Variable Window comparator mode: Variable Hysteresis mode: Variable Window comparator mode: Variable Variable 1 to 10% Fixed 3% F.S.
For models with a solenoid valve, the temperature of the solenoid valve section should be no greater than 50C. All models 1. When controlling valve responsiveness, take note of the size and length of piping, as well as the Cv factor (flow rate characteristics) of the actuating solenoid valve.
The compatibility is indicated for fluid temperatures specified for the respective products (50C or less). 7. Do not use liquids that will cause the wetted sealant to swell.
Ambient and fluid temperature operation is as follows: Digital pressure switches: 0 to 50C Take measures to prevent moisture from freezing in circuits when below 5C, since this may cause damage to the O-ring and lead to a malfunction. The installation of an air dryer is recommended for eliminating condensate and moisture.
less Detection style Karman vortex Flow rate measuring range 0.4 to 4 l/min 1.8 to 20 l /min Note 1) 4 to 40 l/min Operating pressure range Note 2) 0 to 1 MPa 0 to 0.6 MPa Proof pressure Note 3) 1.5 MPa 0.9 MPa Operating fluid temperature 0 to 90C Linearity Note 4) 2.5%F.S. or less (at 25C water) Repeatability 1%F.S. or less (at 25C water) Temperature characteristics 5%F.S. or less (0 to 50C
Power Valve Regulator Valve Series VEX1 Specifications Large Capacity Relief Regulator VEX12001 02 VEX13002 03 04 04 06 10 VEX150VEX17010 12 VEX19014 20 Model VEX11001 02 Air operated, External pilot Operating style Fluid Air, Inert gas 1.5MPa 1.0MPa 0.05 to 0.9MPa 0.05 to 0.7MPa 0.05 to 0.9MPa 0 to 50C(Air operated: 0 to 60C) 0.03MPa 0.01MPa 0.01MPa Free Not required (Use turbine oil No.1
Specifications Max. operating pressure Min. operating pressure 0.8MPa 0.15MPa 5 to 50C 2.7mm 2 (0.15) 180CPM VVQ1000FPG02 1set VQ1000FPGC6M5D 2pcs.