Rated Flow Range: 50 to 250 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1 1/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: Calibration Certificate
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: G, Port Size: 3/4, Output Specification: OUT1: Analog 1 to 5V, Temperature Sensor: OUT2: Analog 1 to 5V, w/Temperature Sensor, Lead Wire: Lead Wire w/M8 Connector, 3m, Units on Label: Instantaneous Flow Rate: Gal/min; Accumulated Flow: Gal; Temp: °C, Bracket: None, Calibration Certificate: None, Made to Order: EPDM Seal
Stations: 10 Stations, Piping: U Side: Closed; D Side: Open, Thread Type: NPT, Flow Switch Type: Remote Sensor Unit, Rated Flow Range: 2 to 16 L/min, Return Unit Components: Flow Adj. Valve: None; Stop Valve: None, Return Port Size: 3/8, Flow Switch Output Specifications: Out 1: Analog 1 to 5 V; Out 2: Flow Rate: None; Temp.: Analog 1 to 5 V; Temperature Sensor: Yes, Lead Wire: w/Lead Wire
This is a legacy product. Please contact us for the latest version.sales@ocaire.com
"END PLATE. 4/5 PORT SOLENOID VALVE. N lb. VQ.
Size: 70D [7 m³/min (ANR)], Thread: N (NPT), Port Size: 10 (1), Option: Auto Drain, 1.0 MPa, Bracket: B (Bracket)
Size: 70D [7 m³/min (ANR)], Thread: N (NPT), Port Size: 10 (1), Option: Auto Drain, 1.0 MPa, Bracket: B (Bracket)
Size: 5000 (3/4 Basis), Thread: N (NPT), Port Size: 10 (1), Accessory: None, Option: 2JR (Metal Case, Drain Guide, Air Flow: Right to Left)
Flow Range: 10~100 l/min, Thread: NPT Thread, Port Size: 1", Wiring Specification: 3m Lead Wire w/Connector, Output Specification: Pulse Output + Analog Output (1~5V)
Flow Range: 10~100 l/min, Thread: NPT Thread, Port Size: 1", Wiring Specification: 3m Lead Wire w/Connector, Output Specification: Pulse Output + Analog Output (4~20mA)
Body Size: 550C [131SCFM (3,700l/Min), Approx. Compressor Output 30HP, (22kW)], Thread: NPT, Port Size: 1, Accessory: None, Rubber Material: Standard, Air Pressure: Medium Air Pressure, 1.6MPa, IN-OUT Direction: -, Degreasing Wash: -, Made-to-Order: -
Size: 1, Reverse Flow: Regulator, Standard, Thread: NPT, Port Size: 1, Accessory: None, Option 1: None, Option 2: R+Y+Z
Size: 3/4, Reverse Flow: Regulator, Standard, Thread: NPT, Port Size: 1, Accessory: None, Option 1: Non-relieving, Option 2: Name Plate & Pressure Gauge in Imperial Units, PSI, °F
Size: 3/4, Reverse Flow: Regulator, Standard, Thread: NPT, Port Size: 1, Accessory: None, Option 1: None, Option 2: Name Plate & Pressure Gauge in Imperial Units, PSI, °F
Size: 3/4, Reverse Flow: Regulator, Standard, Thread: NPT, Port Size: 1, Accessory: None, Option 1: 0.02~0.2MPa Setting, Option 2: Name Plate & Pressure Gauge in Imperial Units, PSI, °F
Size: 3/4, Reverse Flow: Regulator w/Backflow Mechanism, Thread: NPT, Port Size: 1, Accessory: None, Option 1: None, Option 2: Name Plate & Pressure Gauge in Imperial Units, PSI, °F
Size: 1, Reverse Flow: Regulator, Standard, Thread: NPT, Port Size: 1, Accessory: None, Option 1: None, Option 2: R+Z
Size: 1, Reverse Flow: Regulator, Standard, Thread: NPT, Port Size: 1, Accessory: None, Option 1: None, Option 2: Name Plate & Pressure Gauge in Imperial Units, PSI, °F
Size: 3/4, 1, Thread: NPT, Port Size: 1-AV5000 Only, Option: None, Voltage: 24VDC, Lead Wire: DIN Terminal w/o Connector, Surge Suppressor: None, Manual Override: Locking (Slotted), Flow Direction: -, Q: -