Option J: With drain guide Bracket (Option) female thread T: With element service indicator Maintenance space Drain Element service indicator Dimensions with mounting bracket Model Port size (Nominal size B) A B C D E F G H 10 10 10 10 10 10 10 10 10 I 56 66 66 80 80 90 90 100 150 J 15 20 17 22 19 25 21 30 40 K 5 8 8 8 8 10 10 10 15 L 9 12 12 14 14 14 14 16 20 M 5.5 6 6 7 7 9 9 9 11 N 35
Spacer 1 Stations Part no. 2 ISA-16-2 3 ISA-16-3 4 *1 ISA-16-4 5 ISA-16-5 6 *1 ISA-16-6 w Seal for extra station ISA-15 e Threaded plug with seal ISA-12-m 1 pc. Piping Part no. Rc1/8 ISA-12-A G1/8 ISA-12-C q Joint screws (2 pcs.) ISA-161 e Threaded plug with seal ISA-12*1: Spacers are included for 4 and 6 stations. Bracket ISA-14 DIN rail ISA-5-m L Stations Part no.
(kg) Model FH150-02 FH150-03 FH150-04 1/4 80 168.5 197.5 259.5 50 15 25 7 6.5 0.7 3/8 1/2 524
Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order. q Symbol Description Body size 20 30 40 50 60 25 Nil K Note 1) Without backflow function With backflow function With backflow function w + Nil N F Thread type e Rc NPT G + 01 02 03 04 06 10 1/8 1/4 3/8 1/2 3/4 1 Port size r + Nil B Note 3) H Note 2) a Without mounting option With bracket
-2No.PS-OMG0001CN-H / 1 1.5 *3) 3)1 1 -3No.PS-OMG0001CN-H () () () () -4No.PS-OMG0001CN-H () * UL UL1310 2 UL1585 2 UL * FG -5No.PS-OMG0001CN-H * 6 33 () () 30m30m DC(-)() * () CE 050 (5 ) -6No.PS-OMG0001CN-H * 2030 1 LCD * -7No.PS-OMG0001CN-H E DIN 0 1 3 0 NPN2 +15 V 1 NPN2 +420 mA C 2 NPN2 + 3 PNP2 +15 V 2 4 PNP2 +420 mA 5 PNP2 + A B D + 1 2 M SI 1 1 2 L
energy computation Stroke (mm) Example) Cylinder CDQ2B180-100DCM Load weight 10kg Piston speed 100mm/s = 0.1m/s Computation of m2 Note: 1in = 25.4mm 1N = 0.2248lbf 1kg = 2.2046lb 1J = 0.7375ft.lb Basic weight Additional weight 3.48kg 0.08kg 0.74kg Total 4.30kg CQ2B180-100DC Built-in magnet Rod end male threads Computation of E E = = 0.0715J (4.3 + 10) (0.1) 2 21 World Wide Support...
Options J: With drain guide M Mounting Dimensions Model Port Size (Nominal size B) A G F E D C B S 1.6 2.0 2.0 2.3 2.3 3.2 3.2 4.5 4.5 R 4.5 5 5 5 5 9 9 10 12 Q 26 28 28 34 34 50 50 60 76 P 70 84 84 100 100 110 110 130 180 O 54 66 66 80 80 88 88 102 136 N 35 40 40 50 50 55 55 65 85 L 9 12 12 14 14 14 14 16 20 K 5 8 8 8 8 10 10 10 15 J 15 20 17 22 19 25 21 30 40 I 56 66 66 80 80 90 90 100
Note Platinum silver Platinum silver Platinum silver No. q w e r t y u i Material Aluminium die-casted Aluminium die-casted Aluminium die-casted Brass Aluminum/NBR Resin Stainless steel Aluminium die-casted Platinum silver How to Order Sub-plate Replacement Parts Series Sub-plate Hexagon socket head bolt Gasket for sub-plate VP 00 2 3 P 1 M3 x 0.5 x 32 VP300-2-1P (Rc 1/8) VP300-2-2P (Rc
VS4040-S-03 VS4040-S-04 DXT131-15P-06 DXT131-15P-10 DXT132-15-2P-12 DXT132-15-2P-14 XT021-9 DXT132-16 M6 x 25 with washer M8 x 35 3 8 1 2 3 4 VP450 Aluminum alloy Sub-plate !0 1 1 VP470 1 1 4 1 2 VP450 VP470 VP450 VP470 in part numbers are the same symbol for the thread type in How to Order. Gasket !1 Hexagon socket head screw VT3112-00G !2 Thread for mounting valve.
AD38 AD48 Float type auto drain 25 45 45 AD47 N.C. AD37 AD47 Polycarbonate Relieving type Note 1) Assembly includes a bracket and set nuts. Note 2) in part numbers of the round pressure gauge indicates a type of connection thread. No indication is necessary for R; however, indicate N for NPT.
19.2/45.45/93.75/ 187.5/500 kbit/sec 1.5/3/6/12 Mbit/sec Communication speed 125/250/500 kbit/sec 57.6/115.2/ 230.4 kbit/sec 156/625 kbit/sec 2.5/5/10 Mbit/sec Rated voltage 24 VDC Input and control unit power supply: 24 VDC 10% Solenoid valve power supply: 24 VDC + 10%/5% (with power drop warning at approx. 20 V) Power supply voltage range Communication power supply for DeviceNet 11 to 25
fluid Dry air, N2 Detection type Heater type 20 to 200l/min 50 to 500l/min 10 to 100l/min 1 to 10l/min 5 to 50l/min Flow rate measurement range Operating pressure range 0 to 0.5MPa Withstand pressure 1.0MPa 3kPa (at 50l/min) 3kPa (at 100l/min) 10kPa (at 200l/min) 30kPa (at 500l/min) Pressure loss Operating temperature range 0 to 50C (with no condensation) Linearity Note 1) 20% F.S. or less 25%
Simplified Selection Flow Chart Single Axis Electric Actuator Series LTF (AC Servomotor) Single Axis Electric Actuator Series LTF (AC Servomotor) Work load kg Maximum speed mm/s Positioning repeatability mm Guide type Motor type Lead screw Series Capacity Brake Ground ball screw 0.02 Standard motor [Tamagawa Seiki Co., Ltd.] 100W 15 500 0.05 Rolled ball screw 0.02 Ground ball screw 200W 25
(T) DIN (D) L (L) M (M) DC +DIN +-1 2 (G) A C S DIN DIN DIN DIN DIN D 68mm Y 4.57mm T 68mm E 2.32.8mm E, T 1.25-3, 1.25-3S, 1.25Y-3N, 1.25Y-3S D,Y R Y Z EZTZDZLZMZ AC24V (+) D C S VF1000 VF1000 VF1000 VF1000 VF3000 VF3000 VF3000 VF3000 VF5000 VF5000 VF5000 VF5000 () P P(SUP) P A B A(CYL2) B(CYL1) A B EA EB R1(EXH2) R2(EXH1) R1 R2 (B)2 4(A) (B)2 4(A) (R2)3 1 5(R1) (P) (R2)3 1
Body sizes: 16, 25, 32, 40; Maximum work load: 65 kg; Maximum speed: 1200 mm/s; Stroke range: 50 to 500mm in 50mm increments, 600-1200mm in 100mm increments; Positioning repeatability: ±0.01mm, or ±0.02mm (high speed screw lead); Dynamic allowable moment: 8-61% improved vs. LEFS (size and axis dependent)
Body sizes: 16, 25, 32, 40; Maximum work load: 65 kg; Maximum speed: 1200 mm/s; Stroke range: 50 to 500mm in 50mm increments, 600-1200mm in 100mm increments; Positioning repeatability: ±0.01mm, or ±0.02mm (high speed screw lead); Dynamic allowable moment: 8-61% improved vs. LEFS (size and axis dependent)
Body sizes: 16, 25, 32, 40; Maximum work load: 65 kg; Maximum speed: 1200 mm/s; Stroke range: 50 to 500mm in 50mm increments, 600-1200mm in 100mm increments; Positioning repeatability: ±0.01mm, or ±0.02mm (high speed screw lead); Dynamic allowable moment: 8-61% improved vs. LEFS (size and axis dependent)
Guide Suffix: Single Axis, Nominal Size: 25, Speed Specifications: Standard 100 to 1000, Load Specifications: Q [Heavy Load, Nominal Size: 16 (10), 25(20)], Stroke: 1000mm, Motor Placement: On the Top, Standard, Output Type: PNP, Stoppable Positioning Points: 3-point Stoppable, Cable Length: None, Auto Switch: M9P--Solid State, Gen.
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 700, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.2 to 1.0, Specification: Built-in magnet, Port thread type: NPT, Auto Switches: M9P, Lead Wire Length
The MGC guide cylinder is ideal for material handling applications involving stopping, lifting, and pushing. It combines the functions of a conventional linear cylinder, and a non-rotation device. Features include standard air cushions, grease nipple, and switch capability. Other features include, slide or ball bushing bearings, compact design, adjustable air cushion, and lightweight guided