Standard strokes range from 25 to 800mm.Double Acting, Bore Sizes 32, 40, 50, 63, 80, 100, 125, End of Stroke Cushioning, C(P)96 BASE CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, PE, 63MM C95/CP95 DBL-ACT AUTO-SW, 13.24977 lb
Standard strokes range from 25 to 800mm.Double Acting, Bore Sizes 32, 40, 50, 63, 80, 100, 125, End of Stroke Cushioning, C(P)96 BASE CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, PE, 63MM C95/CP95 DBL-ACT AUTO-SW, 7.28409 lb
Standard strokes range from 25 to 800mm.Double Acting, Bore Sizes 32, 40, 50, 63, 80, 100, 125, End of Stroke Cushioning, C(P)96 CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, MD, 40MM C95/CP95 DOUBLE-ACTING
Standard strokes range from 25 to 800mm.Double Acting, Bore Sizes 32, 40, 50, 63, 80, 100, 125, End of Stroke Cushioning, C(P)96 CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, ME, 40MM C95/CP95 DBL-ACT AUTO-SW, 4.18674 lb
Standard strokes range from 25 to 800mm.Double Acting, Bore Sizes 32, 40, 50, 63, 80, 100, 125, End of Stroke Cushioning, C(P)96 BASE CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, RE, 80MM C95/CP95 DBL-ACT AUTO-SW, 12.07162 lb
Standard strokes range from 25 to 800mm.Double Acting, Bore Sizes 32, 40, 50, 63, 80, 100, 125, End of Stroke Cushioning, C(P)96 BASE CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, RE, 80MM C95/CP95 DBL-ACT AUTO-SW, 13.41732 lb
Standard strokes range from 25 to 800mm.Double Acting, Bore Sizes 32, 40, 50, 63, 80, 100, 125, End of Stroke Cushioning, C(P)96 BASE CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, RE, 80MM C95/CP95 DBL-ACT AUTO-SW, 13.41732 lb
Standard strokes range from 25 to 800mm.Double Acting, Bore Sizes 32, 40, 50, 63, 80, 100, 125, End of Stroke Cushioning, C(P)96 BASE CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, RE, 80MM C95/CP95 DBL-ACT AUTO-SW, 8.52861 lb
Standard strokes range from 25 to 800mm.Double Acting, Bore Sizes 32, 40, 50, 63, 80, 100, 125, End of Stroke Cushioning, C(P)96 BASE CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, RE, 80MM C95/CP95 DBL-ACT AUTO-SW, 8.52861 lb
Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient & fluid temperature: -10 to 50°C, 1000 SERIES 5 PORT VALVE, 4/5 PORT SOLENOID VALVE, VVD, 40 lb
Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient & fluid temperature: -10 to 50°C, 3 PORT BASE MOUNTED SOLENOID VALVE, 3 PORT SOLENOID VALVE, VVD, 24 lb
Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient & fluid temperature: -10 to 50°C, 3 PORT BASE MOUNTED SOLENOID VALVE, 3 PORT SOLENOID VALVE, VVD, 24 lb
Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient & fluid temperature: -10 to 50°C, 3 PORT BASE MOUNTED SOLENOID VALVE, 3 PORT SOLENOID VALVE, VVD, 24 lb
(for std model)CY3Magnetically coupled rodless cylinderCY3BBasic type--2 From P. 1174
Fluctuation to temperature VEA252 0 to 50C Operating temperature range 25 to 85% Relative humidity range 2 G (Amplitude: 0.4 mm, 50 Hz) based on JIS C 0911 II Class E4 Vibration resistance No condensation, Relative humidity: 25 to 85% Storage conditions 0.11 kg Weight With Malfunction Detection Circuit: VEA251 (Same main features as VEA250) VEA250 Detection capabilities Breakage of output
Standard strokes range from 25 to 800mm.Double Acting, Bore Sizes 32, 40, 50, 63, 80, 100, 125, End of Stroke Cushioning, C(P)96 CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, ME, 40MM C95/CP95 DBL-ACT AUTO-SW, 3.29939 lb
Standard strokes range from 25 to 800mm.Double Acting, Bore Sizes 32, 40, 50, 63, 80, 100, 125, End of Stroke Cushioning, C(P)96 CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, NE, 50MM C95/CP95 DBL-ACT AUTO-SW, 9.33044 lb
Standard strokes range from 25 to 800mm.Double Acting, Bore Sizes 32, 40, 50, 63, 80, 100, 125, End of Stroke Cushioning, C(P)96 CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, RE, 80MM C95/CP95 DBL-ACT AUTO-SW
Standard strokes range from 25 to 800mm.Double Acting, Bore Sizes 32, 40, 50, 63, 80, 100, 125, End of Stroke Cushioning, C(P)96 CYLINDER, ACTUATOR, C95/C96 TIE-ROD CYLINDER, PE, 63MM C95/CP95 DBL-ACT AUTO-SW, 8.26733 lb
Fluid: air, inert gas , Operating pressure range: 0.1 - 0.7MPa (high pressure style: 1.0MPa) , Cv factor: 1 2 (P A) 0.23; 2 3 (A R) 0.25 , Coil rated voltage: 12, 24VDC; 100, 110, 200, 220VAC , Response time: metal seal 14ms or less; rubber seal 15ms or less , Ambient & fluid temperature: -10 to 50°C, VALVE, BASE MOUNT, VALVE, VQZ1000 VALVE, SOL 4/5-PORT, 2D, VQZ1000 NO SIZE RATING,