SMC Corporation of America
Elite Part Number Search
Search Results "ISE20-P-M5-LD"

M N C D 4-O T Q 2-P E B S K L U W AA A I AP R X AB Y + Stroke J V Z + Stroke AC AD 8-AF AE For standard stroke (mm) Bore size (mm) Stroke range (mm) AC E D AF G AE AD AB AA N M F L K B J AP C H I A 20 25 32 40 50 75, 100, 125, 150, 200 M5 x 0.8 depth 10 16.5 92 60 9.5 depth 6 30 75 11 12 45 25 5.5 80 60 55 108 M8 x 1.25 depth 14 25 24 30 99 M6 x 1 depth 12 16.5 113 65 11 depth 8 30 85 13

Fittings & Tubing Air Cylinders Rotary Actuators Relief port 2 x M5 x 0.8 2 x P through M5 x 0.8 R GC GB E GA MM D C J 2.8 2 x P through A 4 x T counterbore E 0.5 B H S Z (mm) 6 depth 4.8 5 S 10 15 20 25 30 5 Z 10 15 20 25 30 Bore size B C D E GA GB GC H J MM P R T A 13 22 3 23 16 15 13 10 3.2 7 M3 x 0.5 31 10 7 6 10 15 24 4 24 33.5 16 15.5 16 11 M4 x 0.7 3.2 9 6 depth 5 64 69 74 79 84 89

The amount of air requirement of rotary actuator = 0.06 x V x (P/0.1)/t l/min(ANR) V : Inner volume = cm3 P : Absolute pressure = {Operating pressure (MPa) + 0.1} t : Operating time = s CRB2 CRBU2 CRB1 Calculate the required air volume separately for the linear motion part and the rotary motion part.

Contact P/A regarding the bowl assembly supply for PSI and F unit specifications.

LVD Refer to the separate pamphlet P-E00-5A for further details.

[IDFA125F-38/40] () (10 2m) (100.7m) 20 4x R2 1/2 R2 1/2 1130 78 9351 267 1120 655 75 64 (17 ) 40 1276 1375 R ) (14~18) () P.1-5 P.1-5 P.1-5 7122 20 350 700 752 IDFA100F150F 6 4 6.3 IDX-OM-U022 6.

With front lockR (mm) Bore size (mm) W P WA WB WH 20 M5 x 0.8 16 15 (16) 23 30 25 M5 x 0.8 16 15 (16) 25 30 32 Rc1/8 16 15 (16) 28.5 25 40 Rc1/8 16 15 (16) 33 20 50 Rc1/4 18 17 (18) 40.5 20 63 Rc1/4 18 17 (18) 47.5 20 80 Rc3/8 22 22 60.5 20 100 Rc1/2 22 22 71 20 Dimensions inside ( ) are for long strokes.

Bore size (mm) 20 32 40 50 63 80 100 M5 x 0.8 M5 x 0.8 M5 x 0.8 M6 x 1 M8 x 1.25 M10 x 1.5 M10 x 1.5 2 4 4 4 4 4 4 3 3 3 6 11.5 24 34 7. Do not use two cylinders facing one another horizontally or vertically in such a way that their piston rods strike each other. 8.

P EA EB 3 position pressure center A B 5 EB P EA 3 position double check A B 6 EB P EA For the solenoid valve specifications and dimensions, please refer to VQC catalog (ES11-80). Please refer to page 13 for Series EX250 single SI unit dimensions. For details of the Series EX250 SI unit, please refer to the technical instruction manual.

DIN DIN DIN DIN D 68mm Y 4.57mm T 68mm E 2.32.8mm E, T 1.25-3, 1.25-3S, 1.25Y-3N, 1.25Y-3S D,Y R Y Z EZTZDZLZMZ AC24V (+) D C S VF1000 VF1000 VF1000 VF1000 VF3000 VF3000 VF3000 VF3000 VF5000 VF5000 VF5000 VF5000 () P P(SUP) P A B A(CYL2) B(CYL1) A B EA EB R1(EXH2) R2(EXH1) R1 R2 (B)2 4(A) (B)2 4(A) (R2)3 1 5(R1) (P) (R2)3 1 5(R1) (P) 3(R2) 1(P) 5(R1) JIS () Z (B)2 (A)4 1:P 2:

size A B 2-P Port size A B M M 2-J, thread depth K 2-J, thread depth K G1/2 Specifications with bracket Orifice 2, 3, 4.5, 6 Orifice 8, 10 7.5 2.3 Bracket Y 29 Mounting hole 2-5.3 Bracket 22 5.5 52 28 W U 67 X (mm) Grommet Conduit DIN terminal Electrical entry Mounting dimensions Bracket mounting Port size P Model Orifice size A B C D E F H Conduit terminal J M4 M5 M5 M5 M5 K M Q R 50 60

Port size 2-P Port size 2-M, thread depth N 2-M, thread depth N L L K K DIN terminal: D Conduit terminal: T Cable 6.8 to 10 F S Q 27.5 (Q) D F 25 C R C (44) R R E G 1/2 E G 1/2 A H D (S) B B A H 2-P Port size 2-P Port size 2-M, thread depth N 2-M L L K K N.C. dimensions (mm) Grommet: G Conduit: C DIN terminal: D Conduit terminal: T P Port size Rc A B C D E F H K L M N Model Note) U Q V R

x 0.8 depth 7.5 M5 x 0.8 depth 6 Width across flats 8 length 3.5 M10 x 1.25 27 25 8 6.5 M5 x 0.8 32 17.5 15 17 20 10 18 0 0.1 2 24 6 M5 x 0.8 depth 8 M5 x 0.8 depth 6 Width across flats 8 length 3.5 M10 x 1.25 34.5 32 12 6.5 M5 x 0.8 40 23.5 20.5 22 24 14 24 0 0.1 2 30 8 M6 x 1 depth 10 M6 x 1 depth 7 Width across flats 12 length 3.5 M14 x 1.5 42.5 40 13 6.5 M8 x 1.25 [mm] [mm] Port Thread

Refer to p.0-20 and 0-21 for Safety Instructions and common precautions on the products mentioned in this catalog, and refer to p.2.0-3 and 2.0-4 for precautions on every series. Warning If a workpiece is hooked onto the attachment, make sure that excessive impact will not be created at the start and the end of the movement.

500 kPa 0.1 0.001 0.001 0.02 1 0.1 ISE50 (Positive pressure) 0.000 to 1.000 MPa 0.100 to 1.000 MPa 1.5 MPa 0.001 0.01 0.01 0.1 Rated pressure range Operating pressure range and regulating pressure range Proof pressure kPa MPa kgf/cm2 Note 1) Setting/Display resolution ZSE ISE bar psi mmHg inHg PSE Z I SE3 Fluid that will not corrode stainless steel 630 and 304 12 to 24 VDC, Ripple (p-p

Note) $1, %4 will not be required for the one without rear plate. 9-4-6 7 Fine Lock Cylinder with Guide Series MLGC Dimensions Basic style: With rear plate MLGCB--R4-F through Counterbore G Back side 4-H 2-O through Rear plate P Head side cylinder port BP Unlocking port Unlocked when pressurized CL CL1 P Rod side cylinder port MLGC W U A' CNG MNB Courtesy of Steven Engineering, Inc.-230

GD GK GL GQ GR H I J K L M N O Q R S Bore size (mm) 20 25 32 40 M8 x 1.25 depth14 80 5.5 60 3.5 93 M5 x 0.8 54 4 4 35 105 50 25 M6 x 1 14 26 M10 x 1.5 depth18 95 9 70 4 103 M5 x 0.8 62 7 7 40 125 60 32 M8 x 1.25 14 31 M10 x 1.5 depth18 95 9 70 4 104 Rc 1/8 Rc 1/8 62 7 7 40 125 60 32 M8 x 1.25 13 38 M12 x 1.75 depth 21 115 11 82.5 4 115 67 8 8 45 150 75 38 M8 x 1.25 14 47 WH W X Y T U V W

(Resin or rolled steel) LVariation Standard stroke (mm) Bore size (mm) Series Mounting Action Rod end configuration Standard variation Built-in magnet Locking Cancel cap Proximity switch Option 15 20 30 40 20 32 50 63 80 P P P P P P P P P P P P P P P P P P P P P P P P P Double acting Lever style Double acting with spring RSH Flange Adjustable Single acting 4.3-1 Heavy Duty Stopper Cylinder