Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 3/4, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 1, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: Rc, Port Size: 3/4, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate

Rated Flow Range: 0.5 to 4 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate

Rated Flow Range: 0.5 to 4 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: G, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None, Lead Wire: w/M12 -M8 Conversion Lead Wire, 0.1 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: Yes, Lead Wire: w/M12 -M8 Conversion Lead Wire, 0.1 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None, Lead Wire: w/M12 -M8 Conversion Lead Wire, 0.1 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 3/4, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None, Lead Wire: w/M12 -M8 Conversion Lead Wire, 0.1 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 3/4, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: Yes, Lead Wire: w/M12 -M8 Conversion Lead Wire, 0.1 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes, Lead Wire: w/M12 -M8 Conversion Lead Wire, 0.1 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None,

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 1, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: w/Flow Adjustment Valve, Thread: NPT, Port Size: 3/8, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: Yes, Lead Wire: w/M12 -M8 Conversion Lead Wire, 0.1 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: G, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate

Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: w/Flow Adjustment Valve, Thread: NPT, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes, Lead Wire: w/M12 -M8 Conversion Lead Wire, 0.1 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration

Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: NPT, Port Size: 3/4, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: Switch Output, N/P; Temperature Sensor: Yes, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration

Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: w/o Flow Adjustment Valve, Thread: G, Port Size: 1/2, Output Specification/Temperature Sensor: Out 1: IO-Link/Switch Output, N/P; Out 2: None; Temperature Sensor: None, Lead Wire: w/Lead Wire and M8 Connector, 3 m, Unit Specification: Instantaneous Flow: L/min; Accumulated Flow: L; Temperature: °C, Bracket: None, Calibration Certificate

OTo reuse the lubing, cut off the previously lodged portion of lhe lubeOThen pull it back gently to make sure that il has a positive seal. o Rectangular Multi-Connector Series KDI/t Dimensions ..) q E a 6 L 7 4 1 . = z a 3i' -l _*r>'L ;l ann , l:i Panel mount cutout 5/32" l4mm) KDM20 .9 g 7.64" (194) | Panel mount cutout 3-hexagonal screws 5/32" l4mm) Rectangular Multi-Connector Series KDM