Supply pressure range Supply pressure (MPa) Supply pressure (MPa) Regulator for Signals Model Connection R Effective area (mm 2) Max. flow (/min (ANR)) Set pressure (MPa) (Air operated type only) 8 3 AMC310 AMC510 AMC610 AMC810 AMC910 16 55 165 330 550 1 2 300 1,000 3,000 6,000 10,000 VEX1133 0, VEX1233 0, VEX1333 0 Caution 4 3 VEX1533 0, VEX1733 0, VEX1933 0 2 1 1 1.

min) ZSP Retaining screw ISA2 38 33 3/4 Long 0.66 to 1.79 7 14 IF30-06 50 44 3/4 Middle 0.85 to 2.36 9 18 IS 60 53 3/4 Short 1.04 to 2.83 11 22 60 55 1 Short 0.56 to 1.67 10 20 ZSM 100 90 1 1/4 Short 0.57 to 1.67 17 34 PF2 160 140 1 1/2 Short 0.63 to 1.95 26 52 140 125 2 Middle 0.34 to 1.06 23 45 IF IF31-10 280 250 2 1/2 Middle 0.41 to 1.29 45 90 Data 250 220 3 Middle 0.26 to 0.81 40 80 550

AC 110 12 2 12 3 q e w e t y 220 10 1 10 1.5 440 6 1 3 1 550 5 0.8 2 0.5 r b contact w a contact r q DC 24 3 2.5 3 2.5 C C 48 1.5 1.2 1.5 1.25 When rising pressure q w = ON e r = OFF When rising pressure q e r y = ON q w r t = OFF 110 0.5 0.25 0.5 0.2 220 0.25 0.1 0.25 0.1 Insulation resistance: 100 M or more at 500 VDC by megameter Voltage resistance: 2000 VAC/1 min. 16-9-5 2 Series

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Set pressure range 0.1 to 0.4 MPa 0.1 to 0.7 MPa 0.02 to 0.3 MPa 0.05 to 0.7 MPa 0.1 to 1.0 MPa 7 to 100 kPa 27 to 80 kPa 4.5 to 28 VDC (ZSM1-115) 24 to 125 VDC 100 to 250 VAC to 100 VDC to 100 VAC 24 to 220 VDC 100 to 550 VAC Voltage 100 VAC/DC or less

137 21 109 3 198 187.5 161 21.5 133 4 223 212.5 185 22 157 5 248 237.5 209 22.5 181 6 273 262.5 233 23 205 7 298 287.5 257 23.5 229 8 310.5 300 281 18 253 9 335.5 325 305 18.5 277 10 360.5 350 329 19 301 11 385.5 375 353 19.5 325 12 410.5 400 377 20 349 13 435.5 425 401 20.5 373 14 460.5 450 425 21 397 15 485.5 475 449 21.5 421 16 510.5 500 473 22 445 17 535.5 525 497 22.5 469 18 560.5 550

VEX AN AMC Effective area (mm2) Model Connection R(PT) Max.air flow (l/min) AMC310 300 3 8 16 55 165 330 550 AMC510 1,000 3 4 AMC610 AMC810 AMC910 3,000 1 1 6,000 10,000 1 2 2 99.9% of oil mist removal. Over 35dB noise reduction. Refer to p.5.3-1 for details. 5.1-36

260.5 4 121 240 262.5 273 5 137 256 275 285.5 6 153 272 287.5 298 7 169 288 312.5 323 8 185 304 325 335.5 9 201 320 337.5 348 10 217 336 362.5 373 11 233 352 375 385.5 12 249 368 387.5 398 13 265 384 400 410.5 14 281 400 425 435.5 15 297 416 437.5 448 16 313 432 450 460.5 17 329 448 462.5 473 18 345 464 487.5 498 19 361 480 500 510.5 20 377 496 512.5 523 21 393 512 537.5 548 22 409 528 550

Lock Specifications Lock position Rear, Front side 32 20 100 550 (123) 40 50 63 215 (48) 25 2140 (481) 80 Holding force (max.) N (lbf) 5390 (1211) 860 (193) 1340 (310) 330 (74) 3450 (775) Backlash 2mm or less Non-locking type, Locking type Manual release Adjust switch positions for operation at both the stroke end and backlash (2mm) movement positions.

Choose from R(PT), NPT or G(PF) thread styles.Fluid: compressed air, Effective area mm 2 (Cv): male thread style 16 (0.88) - 550 (31); female thread style 12 (0.66) - 55 (3.1), Noise reduction: 35db or more, Oil mist removal: 99.9% or more, Element supply pressure: 0.1MP or less, Ambient and fluid temperature: 5 - 60 C, ELEMENT ASSY, AIRLINE EQUIPMENT, AMC EXHAUST CLEANER, 21, AMC NO

three sides.Energy saving multistage vacuum ejector w/o valve , Nozzle diameter: ø1.2mm , Maximum suction flow rate: 100 /min (ANR) , Air consumption: 63 /min (ANR) , Exhaust specifications: built-in silencer (standard), port exhaust , Vacuum pressure sensor options: digital vacuum pressure switch, vacuum pressure gauge, vacuum adapter, VACUUM GENERATOR, LARGE FLOW, VACUUM EJECTOR, M22, 550

three sides.Energy saving multistage vacuum ejector w/o valve , Nozzle diameter: ø1.2mm , Maximum suction flow rate: 100 /min (ANR) , Air consumption: 63 /min (ANR) , Exhaust specifications: built-in silencer (standard), port exhaust , Vacuum pressure sensor options: digital vacuum pressure switch, vacuum pressure gauge, vacuum adapter, VACUUM GENERATOR, LARGE FLOW, VACUUM EJECTOR, M22, 550

allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, DC Power Supply for HRS100/150 and INR, CHILLER, 729, 550

Choose from R(PT), NPT or G(PF) thread styles.Fluid: compressed air, Effective area mm 2 (Cv): male thread style 16 (0.88) - 550 (31); female thread style 12 (0.66) - 55 (3.1), Noise reduction: 35db or more, Oil mist removal: 99.9% or more, Element supply pressure: 0.1MP or less, Ambient & fluid temperature: 5 - 60° C, OIL BOWL ASSY W/DRAIN PIPING, G, EXHAUST CLEANER, 113, 101.86 lb

allowing mounting and removal of the HRS filter to be done easily and without tools.Compact type thermal-chiller , Single phase, 100/115VAC, Cooling method: air-cooled or water-cooled , Self diagnosis and check display for easy maintenance , Functions: timer operation, low tank level detecting, power failure auto-restart, anti-freezing, Power Terminal Cover HRS090/HRSH090, CHILLER, 729, 550

Air slide table w/built-in guide rail, Bore size *: 6, 8, 12, 16, 20, 25, Standard or symetric styles, Adjuster options: rubber stopper, shock absorber, metal stopper, Auto switch capable, Cyl, Slide Table, GUIDED CYLINDER, 550 lb

.): ø1/4" / ø5/16" / ø3/8" / --, Fluid: Air, Nitrogen, Operating Pressure: -100 kPa to 1.0 MPa (at 20°C), Flow Rate (Positive Pressure) [L/min]1: 250 / 450 / 550 / 650, Flow Rate (Vacuum Pressure) [L/min]: 30 / 70 / 80 / 100, Proof Pressure [MPa]: 1.5 (at 20°C), Operating & Ambient Temperature Range [°C]: 0 - 60, Filtration [µm]: 5 (Filtration efficiency 95%), Filtration Area [mm2]: 1260,