L/min Accumulated pulse flow rate exchange 0.05 L/pulse 0.1 L/pulse 0.5 L/pulse value (Pulse width: 50ms) Note 1) Note 2) Real-time flow rate L/min, gal (US)/min Display units Accumulated flow L, gal (US) Accumulated flow range Note 1) 0 to 9 L 2.5% F.S.
Grommet, Grommet terminal, Conduit terminal DIN terminal, L plug connector, M plug connector Electrical entry VT 100, 200, 12, 24, 48, 110, 220, 240 AC (50/60 Hz) DC Coil rated voltage (V) VP 24, 6, 12, 48, 100, 110 Allowable voltage fluctuation 15 to 10% Inrush VG 5.6 VA/50 Hz, 5.0 VA/60 Hz 3.4 VA/50 Hz, 2.3 VA/60 Hz 1.8 W 2 W Note) Apparent power (AC) Holding W/o indicator light W/ indicator
*6 23 40 50 Standby power consumption when operating [W] *7 16 15 48 43 48 104 Max. instantaneous power consumption [W] *8 Type Non-magnetizing lock specifications Lock unit Holding force [N] 20 39 78 78 157 108 216 *9 Power consumption [W] *10 2.9 5 Rated voltage [V] 24 VDC 10% * 1 The speed is dependent on the workload.
Guide rod type / LEYG Series 3.1 Specification Model LEYG25M L (Top/Parallel) / L D (In-line) LEYG32 M L (Top/Parallel) LEYG32 M L D (In-line) LEYG25 M Horizontal Note 1) 18 50 50 30 60 60 30 60 60 Work load [kg] Vertica 7 15 29 7 17 35 10 22 44 Force [N] Note2) (Set value LEY25S/32S15 to 30%) (Set value LEY25T/32T12 to 24%) 65131 127255 242485 79157 154308 294588 98197 192385 368736 Actuator
Power dissipation (W): For AC , W = V/A cos. For DC, W = V/A. (Note) cos shows power factor. cos = 0.6 2. Surge voltage A high voltage which is momentarily generated in the shut-off unit by shutting off the power. 3.
The result is approximately 10 L/min (ANR). Air consumption (L/min [ANR]) SUP = 0.7 MPa 40 35 30 SUP = 0.5 MPa 25 20 SUP = 0.35 MPa Caution 15 SUP = 0.2 MPa 10 1.
IDX-OM-V020 Original Instructions PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDFA60-23-A,C,L,R,T,V IDFA70-23-A,C,L,R,T,V IDFA80-23-A,C,L,R,T,V IDFA90-23-A,C,L,R,T,V This manual is intended to explain the installation and operation of the product.
For notes w and e, refer to the left. 4B/6B 870 M20 X l 500 AMD1000 w When the element has reached its replacement interval, replace it immediately with a new element.
Operation outside of this range may cause excessive impact, which may result in the damage to the devices. 6 10 Bore size (mm) 6 Operating piston speed (m/s) 0.05 to 0.5 L Allowable kinetic energy (J) 0.012 0.035 100 5st 10st 15st W 100 80 Load weight W (g) 10 10 60 6 Load weight (kg) L 40 1 W 20 0.1 00 5 10 15 20 0.01 0.01 1.0 0.1 Eccentric distance L (mm) Maximum speed (m/s) 10 300 5st
3 r t AS-FE u w i KE i o AS-FG y !0 u AS-FP w e AS-FM Meter-in type Meter-out type !4 !1 Meter-in type Meter-out type AS-D Seal method: Sealant For R, NPT thread Seal method: Sealant For R, NPT thread AS-T e !1 ASP !0 o q r ASN !2 t AQ q w ASV r y AK u t VCHC i i ASR ASQ !0 o y u w Meter-in type Meter-out type e Meter-in type Meter-out type Component Parts Component Parts No.
*r-r-r --r| | | a High-speed | | | response time I I I specifications t t l | | t---{ Pressure display unit | | t--fMfi--l | | f--fkof/cm, l I I [s-f b "t| | I-+-fEr_--] | | tsT kp " ] t l t l I I Cable connector type I S I Straiqht tvpe 3 m I I L I Riqht anqle tvpe 3 m I I j N lWithout cable connector I l L-Bracket Model 7 . l00O tvoe v : 2000 tvoe Pressure [rPa 2 kqf/cm, 3 bar 4 PSI kPa
min L/min L/min L/min Instantaneous Setting/display flow range 2 0.35 to 4.50 1.7 to 17.0 3.5 to 45.0 7 to 110 L/min L/min L/min L/min flow Min. setting/display unit 0.05 0.1 0.5 1 Flow L/min L/min L/min L/min Setting/display flow range 0 to 9 L Accumulated Flow Min. setting/display unit 1 L Pressure Rated pressure range 0 to 1 MPa Proof pressure 1.5 MPa NPN open collector output, PNP open
Note) In the case of body options S and L, the materials of the part nos. e and r are as follows: (Example): VN1-A3BA However all brackets of valve element VNB 1 to 4 are made of stainless steel. (No need to add options S and L.)
59 67 81 84 L 52.5 59 67 81 84 LD LU 13 14 17 23 23 ZZ 116 127 138 171 175 LA 35 41 46 62 62 ZZ Model MUl25 MUl32 MUl40 MUl50 MUl63 lLC 18 22 26 32 32 8 10 10 14 14 9 11 13 16 16 8 10 10 14 14 9 11 13 16 16 CD-MU02 +0.2 +0.4 +0.2 +0.4 +0.2 +0.4 +0.2 +0.4 +0.2 +0.4 Dimensions L, Z, and ZZ are reference dimensions for installing a single knuckle joint, which may be used as a guide.
l (mm) l 300 200 300 MGTL80 P = 0.5MPa m 200 MGTM80 100 P = 0.5MPa Load weight m(kg) Load weight m(kg) 40 50 100 Larger than 75st 50st 25st Larger than 50st 30 20 50 40 25, 50st 10 30 5 4 3 2 20 10 20 30 40 50 100 200 300 1 1 2 3 4 5 10 20 304050 100 200300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) MGTL100 300 200 300 MGTM100 200 P = 0.5MPa 100 P = 0.5MPa Larger than
distance l (mm) 10 400 Eccentric distance l (mm) MGTL100 300 200 300 MGTM100 200 P = 0.5 MPa 100 P = 0.5 MPa Load weight m(kg) Larger than 75st Load weight m(kg) 40 50 100 Larger than 50st 50st 25st 30 25, 50st 20 50 40 10 30 5 4 3 2 20 1 10 20 30 40 50 100 200 300 1 2 3 4 5 10 20 304050 100 200 300400 Eccentric distance l (mm) 10 400 Eccentric distance l (mm) Allowable side load F(N) 1
min (20 L/min 0) 7112 L/min (7 L/min 0) 3.545.0 L/min (3.5 L/min 0.0) 1.718.0 L/min (1.7 L/min 0.0) 0.354.50 L/min (0.35 L/min 0.00) 0.354.50 L/min 1.718.0 L/min 3.545.0 L/min 7112 L/min 20280 L/min 0.01 L/min 0.1 L/min 1 L/min 2 L/min (50 ms) 0.05 L/pulse 0.1 L/pulse 0.5 L/pulse 1 L/pulse 2 L/pulse L/minL 0.5F.S. 0.5F.S. 0.5F.S. 0.5%F.S.(25 ) 9.9 L 9 L 1 0.1L 0.5L 1L NPN
Valve w For VCS20 OR-1860-120P Tilt the screwdriver down in direction q so that the clip slides out in direction w.
Lead Wire Length Lead wire length designation (example) D-A73 L Lead wire length Nil L Z NNote) 0.5m 3m 5m None Note) Applies only to D C type connector switches.