Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style, Compatible with a wide variety of fluids, Effective area mm2 (Cv): 6~19 (0.33~1.05), Max. system pressure (MPa): 1.0, VALVE, MEDIA, AIR PILOT, VALVE, VX2 2-WAY MEDIA VALVE, CA, VX2 BODY PT 1/8 NPT, .44092 lb, VXA21/22, VXA31/32 For Air, Vacuum, Water
Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style, Compatible with a wide variety of fluids, Effective area mm2 (Cv): 6~19 (0.33~1.05), Max. system pressure (MPa): 1.0, VALVE, AIR PILOT, VALVE, VX2 2-WAY MEDIA VALVE, FA, VX2 BODY PT 1/4, .42813 lb, VXA21/22, VXA31/32 For Air, Vacuum, Water, Oil VXA21
Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style, Compatible with a wide variety of fluids, Effective area mm2 (Cv): 6~19 (0.33~1.05), Max. system pressure (MPa): 1.0, VALVE, AIR, VALVE, VX2 2-WAY MEDIA VALVE, GA, VX2 BODY PT 3/8 NPT, .85318 lb, VXA21/22, VXA31/32 For Air, Vacuum, Water, Oil VXA21
Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style, Compatible with a wide variety of fluids, Effective area mm2 (Cv): 6~19 (0.33~1.05), Max. system pressure (MPa): 1.0, VALVE, MEDIA, VALVE, VX2 2-WAY MEDIA VALVE, FA, VX2 BODY PT 1/4, 0.86393 lb
Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style, Compatible with a wide variety of fluids, Effective area mm2 (Cv): 6~19 (0.33~1.05), Max. system pressure (MPa): 1.0, VALVE, MEDIA, AIR PILOT, VALVE, VX2 2-WAY MEDIA VALVE, CA, VX2 BODY PT 1/8 NPT, 0.48684 lb
Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style, Compatible with a wide variety of fluids, Effective area mm2 (Cv): 6~19 (0.33~1.05), Max. system pressure (MPa): 1.0, VX2 BODY PT 3/8, VALVE, VX2 2-WAY MEDIA VALVE, HA, VX2 BODY PT 3/8, 0.65803 lb
Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style, Compatible with a wide variety of fluids, Effective area mm2 (Cv): 6~19 (0.33~1.05), Max. system pressure (MPa): 1.0, VX2 BODY PT 1/4, VALVE, VX2 2-WAY MEDIA VALVE, FA, VX2 BODY PT 1/4, 0.66747 lb
Black (O) Tr D3 PLC Main computer Blue ( ) D2 COM Installation, Piping Caution q2 types of piping are available in perpendicular and in-line directions. 3.6-3 Digital Pressure Sensor GS40 Dimensions 14 10 PSE ZSE4 ISE4 Bracket (Option) R(PT)1/8,1/4 Mounting screw (M4 X 0.7) M5 X 0.8 ZSE5 ISE5 22 14 (Hex. width across flats) 38 ZSE6 ISE6 26 2 2-4.5 600 8 ZSE3 ISE3 (Lead wire length) 19 3 25
Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style, Compatible with a wide variety of fluids, Effective area mm2 (Cv): 6~19 (0.33~1.05), Max. system pressure (MPa): 1.0, VALVE, MEDIA, AIR PILOT, VALVE, VX2 2-WAY MEDIA VALVE, HA, VX2 BODY PT 3/8, .48400 lb, VXA21/22, VXA31/32 For Air, Vacuum, Water
Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style, Compatible with a wide variety of fluids, Effective area mm2 (Cv): 6~19 (0.33~1.05), Max. system pressure (MPa): 1.0, VALVE, AIR, VALVE, VX2 2-WAY MEDIA VALVE, GA, VX2 BODY PT 3/8 NPT, .37478 lb, VXA21/22, VXA31/32 For Air, Vacuum, Water, Oil VXA21
Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style, Compatible with a wide variety of fluids, Effective area mm2 (Cv): 6~19 (0.33~1.05), Max. system pressure (MPa): 1.0, VALVE, AIR, VALVE, VX2 2-WAY MEDIA VALVE, GA, VX2 BODY PT 3/8 NPT, .66910 lb, VXA21/22, VXA31/32 For Air, Vacuum, Water, Oil VXA21
Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style, Compatible with a wide variety of fluids, Effective area mm2 (Cv): 6~19 (0.33~1.05), Max. system pressure (MPa): 1.0, VALVE, MEDIA, AIR PILOT *LQA, VALVE, VX2 2-WAY MEDIA VALVE, CA, VX2 BODY PT 1/8 NPT, 0.363 lb
Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style, Compatible with a wide variety of fluids, Effective area mm2 (Cv): 6~19 (0.33~1.05), Max. system pressure (MPa): 1.0, "VALVE, 2 PORT VALVE
Classification of knob by color difference facilitates distinction between 2 port valves (gray) and 3 port valves (blue). The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Finger valve, standard, 2 or 3 port available, Effective area: 2.0 to 17.5mm², Max. operating pressure: 1.0MPa, Fluid: air, Finger valve, MECHANICAL VALVE, I70, 19 lb
Classification of knob by color difference facilitates distinction between 2 port valves (gray) and 3 port valves (blue). The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Finger valve, standard, 2 or 3 port available, Effective area: 2.0 to 17.5mm², Max. operating pressure: 1.0MPa, Fluid: air, Finger valve, MECHANICAL VALVE, I70, 19 lb
The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Valve: 2 or 3 port (flame resistant), Fluid: air, Max. operating pressure: 1.0MPa, Effective area: 2.0 to 17.5mm², Ambient and fluid temperature: 0 to 60°C, Finger valve, MECHANICAL VALVE, I70, 19 lb
Classification of knob by color difference facilitates distinction between 2 port valves (gray) and 3 port valves (blue). The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Finger valve, standard, 2 or 3 port available, Effective area: 2.0 to 17.5mm², Max. operating pressure: 1.0MPa, Fluid: air, Finger valve, MECHANICAL VALVE, I70, 19 lb
Classification of knob by color difference facilitates distinction between 2 port valves (gray) and 3 port valves (blue). The optional flame resistant model's knob, whether using the 2 or 3 port valve, is red.Finger valve, standard, 2 or 3 port available, Effective area: 2.0 to 17.5mm², Max. operating pressure: 1.0MPa, Fluid: air, Finger valve, MECHANICAL VALVE, I70, 19 lb
Valves for both are easily replaced without changing existing piping.Direct air operated, 2 port valve for manifold, N.C. or N.O. style, Compatible with a wide variety of fluids, Effective area mm2 (Cv): 6~19 (0.33~1.05), Max. system pressure (MPa): 1.0, VALVE, MEDIA, AIR PILOT, VALVE, VX2 2-WAY MEDIA VALVE, FA, VX2 BODY PT 1/4, 0.62814 lb
The LVQ guide ring eliminates lateral motion of the poppet, which reduces internal leakage.2 port chemical valve, Non-metallic exterior , LQ3 integral fitting , Tube O.D.: 1/4", 3/8", 1/2", 3/4", 1", °3, °4, °6, °8, °10, °12, °19, °25 , Orifice: °4, °8, °10, °16, °22 , Cv factor: .35 to 8.0 HIGH PURITY CHEMICAL VALVE. High purity chemical liquid valve. 0.17000 lb. B23.