CJ216 16 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Air cushion is not available for 21-/22-.
75 100 With fitting for purge air discharge 300 Nil H L S Select from Series IDG Flow direction (Right m Left) 500 15 300 Note) In the case of two or more options, indicate them alphabetically. 170 240 300 110 75 40 50 100 150 60 Accessory Thread type Symbol Type Symbol Type None (Standard) Nil B Rc Nil N F With bracket NPT Note) When symbol B is indicated, a bracket assembly with a part
Low Speed Cylinder Double Acting, Single Rod Series CJ2X 10, 16 How to Order Bore size 10 16 10 mm 16 mm Standard stroke (mm) 10 16 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate stroke other than above is manufactured upon receipt of order.
, ISE70/75 1/4" PT VERSION, INSTRUMENTATION, ISE70/75 PRESSURE SWITCH, DA, ISE70/75 1/4" PT VERSION, 0.46297 lb
If the system comprises of both CC-Link Ver.1.00and Ver.1.10-compliant cables, Ver.1.00 specifications are applied to the overall cable length and the cable length between stations. -75- 6.1 Station number setting Set the station number of each driver. Station number setting method Set the station number with the station number switches (STATION NO.) on the driver front.
5.8.2 To Load saved Parameters . 65 5.9 Saving/Loading Project . 66 5.9.1 Saving Project . 66 5.9.2 To Load saved Project . 67 5.10 Saving/Loading Point table . 68 5.10.1 Saving Point table . 68 5.10.2 To Load saved Point table . 69 5.11 Acquisition of motion waveform with graph monitor . 70 5.11.1 Under the setting Tab: Setting of the items to display the graph . 71 5.11.2 Trigger wait . 75
Cable Type Allowable Conductor Temperature C Symbol Name IV 600 V grade polyvinyl chloride insulated wire 60 HIV 600 V grade heat-resistant polyvinyl chloride insulated wire 75 The following table shows the wire sizes and allowable currents for three wires.
Heavy load Standard load Midium load Light load 1 10 50 100 1 0.25 0.49 0.98 1.96 2 20 75 200 2 0.49 0.74 1.47 2.94 3 30 100 300 3 0.74 0.98 1.96 3.92 4 40 125 400 4 0.98 1.23 2.45 4.90 5 50 150 500 5 1.23 1.47 2.94 5.88 6 75 200 600 6 1.47 1.96 3.92 7.84 7 100 250 700 7 1.72 2.45 4.90 9.80 8 300 300 800 8 1.96 2.94 5.88 11.76 9 500 500 900 9 2.21 3.92 7.84 15.68 10 1000 1000 1000 10 2.45
Reference Information . 72 8.1 LRC Checksum Calculation Procedure . 72 8.2 CRC Check Sum Calculation Procedure. 72 8.3 Communication Response Time Guides . 75 8.4 ASCII Code List . 76 3 - LATCA Series Controller 1. Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
. / guideline switching stroke 75% 0.4 Example) When a cylinder whose stroke is 50 mm is operated at 100 mm/sec, the formula is: 50 / 100 = 0.5. As the value is greater than 0.4, deceleration control is possible. When a cylinder whose stroke is 50 mm is operated at 200 mm/sec, the formula is: 50 / 200 = 0.25.
When the switch point of the display value = 75 with ISA3-H The weight is 50, so X = 25. In window comparator mode, error output, switch output off The boundary value is fixed.
Nil S n 8 12 16 20 10, 20, 30 20, 30, 50 30, 50, 75 30, 50, 75, 100 Auto switch Nil Without auto switch (Built-in magnet) For the applicable auto switch model, refer to the table below.
How to Order Bore size 10 16 10mm 16mm Standard stroke (mm) 10 16 15, 30, 45, 60, 75, 100, 125, 150 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 Intermediate strokes other than the above are produced upon receipt of order.
CRB1BW635 0.030 0 5 0.030 25 0 83 60 PORT 4-R7.5 Top ports (port position): CRB1BW63-SE, CRB1BW63-DE 75 0 0.052 28h9 17 0.006 0.017 15g6 5 B port B port 25 45 80 21 When the B port of body (B) is threaded, it is closed with a Rc 1/8 plug. 3 14 3 14 29 22 Body (B) 15 Body (A) 2-Rc 1/8 A port 14 14.9h9 0 0.043 12 15g6 0.006 0.017 28h9 0 0.052 25 A port B port 75 2-Rc 1/8 8 (8) 82 27
(n = 2, 4, 6 ) 75 + 55 (n 2) 20 + 50 n 2 2 D-B59W 20 75 15 (n = 2, 4, 6 ) D-A3 D-G39 D-K39 D-A44 35 100 10 35 + 30 (n 2) 100 + 100 (n 2) n: Number of auto switches Theoretical Output Mounting Unit (N) Caution Operating pressure (MPa) Bore size (mm) Piston area (mm) Rod size (mm) 1 1.5 2 2.5 3 3.5 Operating direction 1.
However, the piston speed at this time should be adjusted to the minimum speed. 15 65 10 (n = 2, 4, 6 ) 65 + 50 (n 2) (n = 2, 3, 4, 5 ) 20 + 50 n 2 2 20 65 10 D-H7LF (n = 2, 4, 6 ) 15 + 50 n 2 2 D-B5 D-B6 15 75 10 (n = 2, 4, 6 ) Mounting 75 + 55 (n 2) (n = 2, 3, 4, 5 ) 20 + 50 n 2 2 Caution D-B59W 20 75 15 (n = 2, 4, 6 ) 1.
4 E1,2,3,4... 110+100111 Same surface 7s+50(n-2) n=2,3,4,,.. 90+s0(n-2) 110+50 (n'2) with 1 1 0 90 100 1 1 0 D-A4 Wi$l2 Differenl sudace 35 75 80 90 Same surface 100 100 r00 100 Different 7s+30(n-2) 80+30(n,2) 90+30(n-2) Same 100+100(n 2), n=2,4,5,8... l 0 75 80 90 Different 80 90 D-B5.86 D-G5.K5 Same 35 80 90 With n Ditlerenl 35+30(n-2) n=1,2,3,4.. n=2,4,6,a.. 80+30(n-2J E2,4,6,8... 90+30
port 2-M5 x 0.8 33 10 J 5 12 9.5 Mounting reference planes B D Section AA MXP12-25 Without magnet and switch rail 2-M3 x 0.5 depth 3.5 For rail mounting 2-M2 x 0.4 depth 3 For magnet mounting 8 5.7 3.5 6-M4 x 0.7 depth 4.5 20 20 L (mm) Z MXP12-15 MXP12-25 SMXP12, #1 (#1 + #3) SMXP12, #2 (#2 + #4) L K J V H S G M W Model 24 22 68 59 40 15 76 10 29 55 MXP12-15 42 40 98 89 60 25 106 30 49 75
PV SV HRS090 Series 5.20Communication function 5-75 HRX-OMT002 Chapter 5 Display and setting of various functions 30. Perform setting for the contact input signal 1 with [] key or [] key, and press [SEL] key to enter.
75 71 Accessories Operation Manual (for installation/operation) 2 pcs.