0 10 20 30 40 50 60 70 80 0 20 40 60 80 100 120 140 160 180 Time (minute) Time (minute) Pressure Loss in FacilityWater Circuit The values shown on the performance chart are not guaranteed, but typical.
20 30 40 50 0 10 20 30 40 50 Circulating fluid temperature [] Circulating fluid temperature [] 50Hz 60Hz Fig. 9-4 Cooling capacity(HRS050--20-(BJM)) 9.5 Heating capacity 9.5.1 HRS050-A-20-(BJM) 2000 2000 Ambient Ambient temperature temperature 1500 1500 5 Heating capacity [W] Heating capacity [W] 5 20 20 25 25 1000 32 1000 32 40 40 500 500 0 0 5 10 15 20 25 30 35 40 5 10 15 20 25 30 35 40
Section Attachment Model Type G46-10-02 G46-2-02 G46-10-02-L G46-2-02-L G36-10-01 G36-2-01 G36-10-01-L G36-2-01-L Round type Standard 0.02 to 0.2 MPa setting Standard 0.02 to 0.2 MPa setting Standard 0.02 to 0.2 MPa setting Pressure gauge Note 1) Round type (with color zone) Square embedded type Note 2) GC3-10AS [GC3P-010AS (Pressure gauge cover only)] GC3-2AS [GC3P-010AS (Pressure gauge
(mm) Model OO PP SS VV QQ RR TT UU Applicable gasket ML1C25 ML1C32 ML1C40 C11.2 10 14 37 24 8 27 20 8 C11.2 16.5 18 46 30 12 32 22 8 C14 17 23.5 53 40 12.5 34 26 10 Model A B C D E F G H I J K L M N P Q S T O R U W Z V Y ML1C25 ML1C32 ML1C40 274 260 137 140 88 108 87 85.5 60 74 97 100 42.5 26 34 206 28 24 5.6 9 5.5 8.5 9.5 M5 x 0.8 M6 x 1 11 322 306 161 160 108 131 101 99.5 64 92 118 120
Approx. 216 with AMC610-10 installed (approx. 261.5 with AMC810-14 installed) D side entry (LD) Approx. 100 with AMC610-10 installed Approx. 100 with AMC610-10 installed 100 with AMC610-10 installed 100 with AMC610-10 installed 118 (135) 159 (172.5) 159 (172.5) (approx. 105 with AMC810-14 installed) (105 with AMC810-14 installed) 118 (135) (approx. 105 with AMC810-14 installed) (105 with
Enable Generates an error. 1 -10..10 V -5..5 V -20..20 mA 0..10 V 0..5 V 1..5 V 0..20 mA Set the analogue input device range per channel. Analogue input range (Range) Selects the analogue input range. -10..10 V 2 4..20 mA Offset binary Offset binary. Sets analogue data type which is output to PLC per unit.
They can be ordered in lots of 10 pieces. d D Series SY3000 SY5000 SY7000 Part No.
L/A2 Link, Activity (Port2, 100 Mbps) Green LED is flashing 8 Power supply connector pin layout 7/8 inch, 4 pin, plug Link, No Activity (Port2, 10 Mbps) Orange LED is ON 1 9 Danger: DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. 2 Link, Activity (Port2, 10 Mbps) Orange LED is flashing No.
C 10 100 PF2A521 D 20 200 PF2A551 E 50 500 Analogue output A B Voltage output 1 V 5 V Current output 4 mA 20 mA Rated flow range [L/min] Model Min.
or less 95 Metal seal 13 or less 0.1MPa 0.2MPa Double 3 position (double solenoid) 4.5 (0.25) SQ1231D 15 or less 95 Rubber seal 20 or less 0.15MPa 4 position 2.9 (0.16) Closed center SQ1330 20 or less 100 Metal seal 26 or less Ambient and fluid temperature 10 to 50C Note 1) SQ1000 3.2 (0.18) SQ1331 25 or less 100 Rubber seal 33 or less Not required Lubrication 3.2 (0.18) SQ1430 20 or less
1.0 to 38.0 2 to 76 8 to 186 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 flow Flow Min. setting/display unit 0.5 2.0 0.5 1.0 2.0 CFM x 10-2 CFM x 10-2 CFM x 10-1 CFM x 10-1 CFM x 10-1 Accumulated Setting/display flow range 0 to 9 ft3 x 10-2 0 to 9 ft3 x 10-1 flow Min. setting/display unit 1 ft3 x 10-3 1 ft3 x 10-1 Conversion of accumulated pulse 0.5 2.0 0.5 1.0 2.0 ft3 x 10-2/
8.2 115 3.1 80 5.6 100 8.2 115 2 60 3.1 80 5.6 100 8.2 115 2 60 2 60 VX3 No freezing Equivalent size VXA VN Pilot Operated Solenoid Valve Specifications LVC Pilot solenoid valve Electrical entry Coil rated voltage (V) AC (50/60/Hz) DC VO301-00T-X302 Conduit terminal 100 V, 200 V, Other voltage (Option) 24 V, Other voltage (Option) 15 to 10% of the rated voltage Class B or equivalent (130C
Flexible tubing KM 20 m roll 100 m reel TAU1208 TAU3220 TAU0425 TAU0604 TAU0805 TAU1065 Model KF Tubing O.D. (mm) 12 3.2 4 6 8 10 Tubing I.D.
Product Specifications Model LC3F212-5A3 LC3F212-5A5 24 VDC 10% Power supply voltage Max. 1.3 A Max. 2.3 A Front side label color Gray Blue Input signal Photocoupler input 24 VDC 10% Max. 8 mA/point Selction of thrust 100% or set value (setting range 10 to 70% F.S.)
Electrical entry AC (50/60 Hz) DC 100, 200, 110, 220, 240 24, 12 10% of rated voltage Coil rated voltage (V) Allowable voltage fluctuation 1.55 (With indicator light: 1.65) DIN/Conduit terminal with indicator light: 1.7 1.5 Note) AC Apparent power (VA) Without indicator light Note) Power consumption (W) DC With indicator light 1.55, DIN/Conduit terminal with indicator light: 1.75 A rectifying
Standard Strokes Bore size [mm] Standard stroke [mm] 12, 16 10, 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250 20, 25 20, 30, 40, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 32 to 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400 Made to Order: Individual Specications (For details, refer to page 491.)
40 30 20 10 0 Initial value Measuring point 6 4.
Thread type Opening/Closing stroke (mm) Cylinder bore Symbol Type 10 20 40 60 16 30 60 80 20 40 80 100 25 50 100 120 32 70 120 160 40 100 160 200 Symbol Nil 10 to 25 M thread Rc NPT G Nil 1 2 TN TF 32 to 40 Double acting Action D Applicable Auto Switch/Refer to pages 761 to 809 for further information on the auto switches.
D Model Port size D A B C , 1 4 3 8 1 2 , ALF400 ALF400-06 ALF500 ALF600 ALF800 ALF900 80 85 90 100 100 100 239 247 296 320 339 345 44 46 48 51 59 63 3 4 1 3 4, 1 1 1 1 4 1 2 , 2 Dimensions: Auto Feed Tank Float switch Contact point capacity: AC: 15 VA, DC: 15 W Contact point construction: 1a, 1b M Width across flats 12 Float switch Lubrication plug Model A 174 174 234 234 B 70 70 108 108
Regulator for adjusting supply pressure for additional air blow Regulator for adjusting supply pressure to the dust collector Ionizer Offset voltage: 10 v Static neutralization distance: 100 mm Discharge time: 0.3 s 1000 VR100 V q Air blow e Air blow Ion blow t w Air blow adjustable range r Secured a large static neutralization space.