19 19 19 Weight kg 0.5 0.6 0.7 Weight kg 0.5 0.6 0.7 NAAMS code ACA206M ACA207M ACA208M NAAMS code ACA216M ACA217M ACA218M A B C D E F G H I A B C D E F G H I Part no.
ON/OFF / / 2 3 3 2 1 2 / -20- 3.3. [] LEC LEC / P.32 5.3 <> NPNPNP LEFS16A-100 NPN <> INPIN []INP ON ON INP ON OFF -21- <> No.1 01 a b c d e f g h i j k a ABSINC No. 1 2 mm/s mm mm/s2 mm/s2 % % mm/s % mm mm mm 0 ABS 250 50.00 3000 3000 0 0 0 100 48.00 50.00 0.50 1 ABS 250 0.00 3000 3000 0 0 0 100 0.00 2.00 0.50 ABS()/ / INC()// b c d e f 00 g h i 100%DC24V 250% j 12
D-C80 D-C73C, D-C80C Reed BMA2-020 BMA2-032 BMA2-040 BMA2-025 D-H7A1, D-H7A2, D-H7B, D-H7C D-H7NW, D-H7PW, D-H7BW D-H7LF, D-H7NF, D-H7BAL Solid state Reed Solid state D-B53, D-B54, D-B64, D-B59W D-G5NTL BA-32 BA-04 BA-01 BA-02 Reed Solid state D-A33, D-A34, D-A4 D-G39, D-K39 BD1-02M BD1-02 BD1-04M Precautions Be sure to read before handling.
Note 2) 3/16", 3/8", 1/2" are made of brass (Electroless nickel plated). 15-9-95 5 Dimensions L5 Elbow type D3 H Applicable tubing O.D. d (Hexagon width across flats) L4 L3 A D1 M1 L1 L2 D2 T Metric Size Inch Size d T H D2 D3 L1 L2 L3 L4 L5 A M1 d T H D1 D2 D3 L1 L2 L3 L4 L5 A M1 D1 Model Model AS121F-M5-23T AS121F-U10/32-01T 1/8" 8.4 17.3 22.1 12.3 3.2 8.4 5/32" 9.3 12.7 17.3 22.1 12.3
Accessory Optional specifications D Float type auto drain (N.O.)
The guideline is 80% or less. 0 to 100 % 12 Effective load ratio The continuous effective load current is displayed. The effective value is displayed relative to the rated current of 100%. 0 to 300 % 13 Peak load ratio The maximum torque is displayed.
Applicable cable O.D. 6 to 8 (D, DZ) P Pg9 J (DIN terminal: D, DZ) I (Grommet: G) F (Air operated) Pilot port 12 (P1) 2 x (Back side 10 (P2)) 4 x M 8 1 Manual override (Non-locking push type) P1 D S Q E 15 B A H (DIN terminal: D, DZ) G (Grommet: G) A R B C Main port 1 (A) (Back side 2 (B)) Port side: refer to table below Model Main port 1(A), 2(B) A B C D E F G H I J K L M N P Q R S VNB2V
(Values at the initial period) VFN Base mounted JIS Symbol Solenoid Specifications Option Grommet (G), Plug connector (L), Plug connector (M), DIN terminal (D) 100, 200, 24 , 48 , 110 , 220 Electrical entry DC AC 50/60 Hz Coil rated voltage (V) 24, 6 , 12 , 48 Allowable voltage fluctuation (%) 15 to +10% of rated voltage Caution Coil insulation type Class E or equivalent (120C) (2) Temperature
SF4 5 D 5 D 23 Q VO307 CE-compliant Coil rated voltage CE-compliant Coil rated voltage CE-compliant Nil Q 1 2 3 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz CE-compliant Nil Q 1 2 3 100 VAC 50/60 Hz 200 VAC 50/60 Hz 110 VAC 50/60 Hz 220 VAC 50/60 Hz 24 VDC 12 VDC 240 VAC 50/60 Hz Note) Electrical entry: D or DZ only 4 4 5 6 5 6 Manual
Min. to Max. a to b c to d PF3W7 oC Common 0 to 100 -10 to 110 0 to 1000 -100 to 1100 : The flow ranges and relationship between the fluid and PD are shown in the figures below.
190 180 CRJB05 CRJB1 CRJU05 CRJU1 D-F8 Basic type Front ported D-F9 Side ported With external stopper D-M9 11-6-3 4 Series CRJ Precautions Be sure to read before handling.
190 180 CRJB05 CRJB1 CRJU05 CRJU1 D-F8 Basic type Front ported D-F9 Side ported With external stopper D-M9 11-6-3 4 Series CRJ Precautions Be sure to read before handling.
100 100 100 100 100 Vacuum pressure Suction flow rate [L/min (ANR)] Air consumption [L/min (ANR)] Suction flow rate [L/min (ANR)] Air consumption [L/min (ANR)] 80 80 80 80 80 80 Vacuum pressure [kPa] Vacuum pressure [kPa] Vacuum pressure [kPa] Vacuum pressure [kPa] Vacuum pressure Air consumption 60 60 60 60 60 60 Suction flow rate Air consumption 40 40 40 40 40 40 Suction flow rate 20 20
Use a D-class ground connection (ground with a resistance of less than 100). The cross sectional area of the grounding cable shall be 2 mm2 or more. The Grounding point should be as near as possible to the controller. Keep the grounding cable as short as possible.
/A8, D-A7H/A80H, D-A73C, A80C, D-C7/C8, D-C73C/C80C, D-E7A, E80A, D-Z7/Z8, D-9/9A, D-A9/A9V, D-A79W The auto switches above do not have a built-in contact protection circuit.
C H G F E D B A Port size Model J K 959 317 289 363 157 152 910 260 R 3/4 IDU11C/11D 571 580 30 70 1009 337 309 383 207 175 960 280 R 1 IDU15C : Power source 220 to 240VAC 7
8 mm, I.D. 5 mm, Length 100 mm to 500 mm O.D. 8 mm, I.D. 5 mm, Length 100 mm to 500 mm Supply pressure [MPa] 0.25 Flow meter 6 Union tee fitting 0.20 O.D. 6 mm, I.D. 4 mm, Length 500 mm O.D. 6 mm, I.D. 4 mm, Length 500 mm O.D. 6 mm, I.D. 4 mm tube (Length 10 mm) 0.15 0.10 O.D. 6 mm, I.D. 4 mm, Length 100 mm O.D. 6 mm, I.D. 4 mm, Length 100 mm 0.05 Ionizer 0.00 0 300 100 200 Flow rate [L/min
(mm) A B C D E F G H J L Port size Bracket part no.
AS1001F-23D-X214 AS AS-FE KE AS-FG AS-FP AS-FM AS-D AS-D AS-T ASP ASN AQ ASV AK VCHC ASR ASQ 743 Dual Speed Controller Adjustable by Flat Head Screwdriver with One-touch Fitting ASDF-D Series RoHS Model Applicable tubing O.D.