Model LEY 25E-X8 LEY 32E-X8 LEY 40E-X8 (3000 [mm/s2]) 20 40 60 30 45 60 50 60 80 Horizontal Work load [kg] Note1) (2000 [mm/s2]) 30 55 70 40 60 80 60 70 90 Vertical (3000 [mm/s2]) 7 15 29 10 21 42 12 26 52 Pushing force [N] Note2) Note 3) Note 4) 63 to 122 126 to 238 232 to 452 80 to 189 156 to 370 296 to 707 132 to 283 266 to 553 562 to 1058 Actuator specifications Speed [mm/s] Note 4) 18
Pilot port position for pilot valve 18 Revision history A:Create New 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2022 SMC Corporation All Rights Reserved 19
When it is necessary to disassemble, please contact the SMC Sales representative. 18 - Revision history 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2019 SMC Corporation All Rights Reserved 19 -
Parameter Definition Item Content Default setting range setting Generated error when control and input power supply voltage goes over approx. 29 V or under 18 V. Disable Does not generate an error. Enable Generates an error. Power supply for control and input voltage monitor Unit 1 Generated error when output power supply voltage goes over approx. 29 V or under 19 V.
No.EX-OMN0038-C PRODUCT NAME Fieldbus system Analog unit MODEL / Series / Product Number EX600-AXA EX600-AYA EX600-AMB Table of Contents Safety Instructions 3 System Outline 9 Assembly 10 Mounting and Installation 12 Installation 12 Wiring 14 Analog input unit Model Indication and How to Order 15 Names and Functions of Product 15 Mounting and Installation 16 Wiring 16 LED Display 18 Specification
The same name must be used for the connected SI unit device name (page 18) and the device name set in the hardware configuration.
Power supply voltage effect 1%F.S. or less based on the analog output at 18 V ranging from 12 to 24 VDC Enclosure IP40 Ambient temperature range Operation: 0 to 50 oC, Storage: -10 to 70 oC (No condensation or freezing) Environ ment Ambient humidity range Operation, Storage: 35 to 85%RH (No condensation) Withstand voltage 1000 VAC, 50/60 Hz, 1 minute, between terminals and housing Insulation
Generates error when control and input power supply voltage is above approx. 29 V or below 18 V. Power supply for control and input voltage monitor [PWRC_Mon] Enable Generates an error. 1 Disable Does not generate an error. [Monitor 24V_C] Power supply for output voltage monitor [PWRO_Mon] Generates error when output power supply voltage is above approx. 29 V or below 19 V.
For details of each setting, refer to page 18 to 20 of this manual. Please refer to the PLC manufacturer's manual etc. for details of programming and addresses. For the PLC protocol and programming refer to the relevant manufacturer's documentation.
If the stain is persistent, wipe off with a cloth soaked in a dilute solution of neutral detergent and wrung out tightly, and then finish with a dry cloth. 15 No.VQC1000V-OMM0002-B 16 No.VQC1000V-OMM0001-B 17 No.VQC1000V-OMM0001-B 18 No.VQC1000V-OMM0001-B 19 No.VQC1000V-OMM0001-B 20 No.VQC1000V-OMM0001-B 21 No.VQC1000V-OMM0001-B 22 No.VQC1000V-OMM0001-B 23 No.VQC1000V-OMM0001-B 24 No.VQC1000V-OMM0001
starts at zero from LSB (least significant bit). (3) Fuse disconnection details The power supply fuse disconnection for the SI unit solenoid valves can be monitored by the link special register of the master station. 0: Normal 1: Fuse disconnected Buffer area of master station Example: QJ61BT11N b15 b14 b13 b12 b3 b2 b1 b0 (688H)SW0088 16 15 14 13 4 3 2 1 (689H)SW0089 32 31 30 29 20 19 18
g 1.9 g 2.1 g 3.8 g 4.6 g -12No.PS-OMG0004-D Analog output Range Rated pressure range A B C For vacuum 0.0 to -101 kPa 0 -101 kPa 10.1 kPa For compound -100 to 100 kPa -100 kPa 100 kPa For positive pressure -0 to 1 MPa 0 1 MPa -0.1 MPa -13No.PS-OMG0004-D Dimensions PSE54(A)M3 M5 PSE54(A)-M3 PSE54(A)-M5 A 10.8 11.5 B 3 3.5 PSE54(A)01 N01 PSE54(A)R04 R06 PSE54(A)-R04 PSE54(A)-R06 A 4 6 B 18
No.EX-OMP0025-A PRODUCT NAME SI unit for AS-Interface MODEL / Series / Product Number EX250-SAS# Table of Contents Safety Instructions 2 Product Outline 8 Model Indication and How to Order 9 Summary of Product elements 9 Mounting and Installation 10 Installation 10 Wiring 11 Setting 14 Indication 16 Connection between SI unit output and the solenoid valve 17 Data bit 18 Maintenance 19 Troubleshooting
Descriptions and Functions Housing cover NO.2 NO.18 NO.1 NO.17 Switch cover LED PWR. COMM ERR EX140-SCS1 BS+ BDH BDL BSFG 24V 0V No. Terminal Board M3 terminal screw in use. 5-1. LED indication LED Content PWR Lights and lights off as power supply for communication is turned on and off respectively.
RX40 164H RY4F to RY40 3 E5H RX5F to RX50 165H RY5F to RY50 E6H RX6F to RX60 166H RY6F to RY60 RY0D Output No.13 4 E7H RX7F to RX70 167H RY7F to RY70 RY0E Output No.14 E8H RX8F to RX80 168H RY8F to RY80 RX0F RY0F Output No.15 5 E9H RX9F to RX90 169H RY9F to RY90 RX10 RY10 Output No.16 EAH RXAF to RXA0 16AH RYAF to RYA0 RY11 Output No.17 6 EBH RXBF to RXB0 16BH RYBF to RYB0 RY12 Output No.18
When mounting the fittings, after inserting the fitting assembly until it stops, then put the clip into the prescribed position completely. 18 - Doc. no. ZQ-OM00801-D Solenoid Valve Manual Override Vacuum for the ejector or the vacuum pump system is generated or released by manual operation. Use the manual override after confirming That there is no danger.
. size size torque XLAV-16 M2 0.2 -25 -40 -50 -63 M3 0.8 -80 17 XL-OMV0016 Revision history 1st printing: VZ 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL http://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2017 SMC Corporation All Rights Reserved 18
. -18- Option symbol 8 8J Semi-standard symbol Semi-standard: 8 Semi-standard: 8J Piping port Piping port (9) Part No. (9) Part No. thread ty pe thread ty pe Rc Rc C4LF-8J-A C4LF-8-A G G C4LFF-8J-A NPT C4LF-8(Z)-A NPT C4LFN-8J(Z)-A Appearance and part No.
The allowable upper and lower range of temperature can be set between 0.1 and 10 C. 3.6.9 Warning of output interruption This function raises alarm and stop operation safely when a critical error detected (However, operation continues in case of ERR 15 and ERR 18.). When a alarm is detected, the display shows ERR and a alarm number.
Do not The product has a self-check function that can detect faults with the product and interrupts the output to the thermo modules, stopping operation (However, operation continues with ERR 15 and ERR 18). This function gives an alarm if a critical error happens, the display shows ERR and an alarm number.