For flow characteristics, refer to pages 14-19-37 to 14-19-38 for external dimensions, refer to pages 14-19-41, 43, 45, and 47. 14-19-35 32 Series IDG Standard Specifications/Unit (Type M, Type V) [Standard dew point: 60C] Model Standard dew point: 60C IDG75SM IDG100SM IDG60SM IDG60SV IDG75SV IDG100SV AFM40 AFD40 AR40 Micro mist separator Mist separator Component equipment Regulator (Type
A 152.5 154 B 52.5 54 E 52 64 I 69 86 J 5 7 M 40 50 N 5.5 6.6 O counterbore 9 depth 7 11 depth 8 T 44 56 Z 14 19 W 66 80 U 35 41 Bore size (mm) 40 50 Data Note 1) Dimensions without auto switch are the same as drawing above. Note 2) These figures show the dimensions when equipped with D-A73 or D-A80 auto switches.
5 Brass Spring seat i 6-3-40 41 41 Series CJ2K Air Cylinder: Non-rotating Rod Type Single Acting, Single Rod, Spring Return/Extend Single Acting, Spring Return: Basic Style (B) CJ2KB S Port location on head cover Bore size Stroke Piping port M5 x 0.8 Piping port M5 x 0.8 Mounting nut Rod end nut CJ1 CJP S + Stroke Rod section CJ2 Port location on head cover: Axial location (R) Z + Stroke
A A1 E1 L1 NZ 16 16 20 22 28 38 44 34 41 42 56 71 79 25 30 30 40 50 55 20 25 32, 40 50, 63 80 100 20 25 32, 40 50, 63 80 100 I-G02 I-G03 I-G04 I-G05 I-G08 I-G10 Y-G02 Y-G03 Y-G04 Y-G05 Y-G08 Y-G10 34 41 42 56 71 79 25 30 30 40 50 55 IY-G02 16 20 IY-G03 20 22 IY-G04 36 28 IY-G05 44 38 IY-G08 56 44 IY-G10 Knuckle pin and snap ring are included. 64 Knuckle Pin (Common with double clevis pin
Width across flats of attachment 3/8 24 mm 1/2 28 mm 3/4 35 mm 1 41 mm Ensure that the piping is tightened to the required torque. The tightening torque for connection threads is shown in the table below.
Mode button 1s Set button 1s or Mode button 1s Set button 1s Fig. 41-1 No.IP8S-OM09 57 Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant D constant Fig. 41-2 Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant D constant Fig. 41-3 Mode button 1s Set button 1s or Mode button 1s Set button 1s P constant I constant
(1) Operation check by test drive . 41 (2) Operation check with the monitor . 41 5.4.1 Operation check by test drive. 41 (1) Operation check by test drive in easy mode . 41 (2) Operation check by test drive in normal mode . 43 5.4.2 Operation check with monitor . 45 (1) Operation check with monitor in easy mode . 45 (2) Operation check with monitor in normal mode . 46 6.
- [] PLC RWw RWw bit 10.1.2 0 (2) [OUT]()[] (P.41) 1 ON OFF OFF 2 10.1.2 (2) [OUT]()[] (P.41) 3 4 5 0 6 ON ON *1 7 *1 8 *2 9 *1 *2 A *2 B (*1*2) C 17.
Supply port PD (mm) D FC GC 6 8 11 15 A B C EA EB FA FB FD FE FF FG GA GB GD 83 111 155 200 256 Model MIW8-8 MIW12-12 MIW20-20 MIW25-25 MIW32-32 M3 x 0.5 M3 x 0.5 M5 x 0.8 M6 x 1 22 34 43.5 58 73 2.6 3.3 5.1 6.8 8.6 9 12.5 16.5 20 24.5 28 37 54 71 80 4 4.5 6.5 10 12.5 7 9.5 12.5 17 22 16 21 29.5 40 47 15 19 25.5 37 51 34 44 64 84 95 18 23 28.5 41 55 57 26 35 48.5 66 87 6 (Effective depth
If screws other than those specified are used, it may cause the switch to be damaged. 3 41 41 38 5 68 68 63 Auto Switch Dimensions Unit: mm Auto switch internal circuits D-M9 Mounting screw M2.5 x 4 Slotted set screw D-M9N D-M9B, N, P Common DC (+) Brown [Red] Indicator light 2.6 Switch main circuit Switch main circuit Switch main circuit OUT Black [White] 2.7 2.8 4 22 DC (-) Blue [Black]
Dimensions (mm) Recommended flow m3/min (ANR) Model Port size R Effective area (mm2) Weight (g) A B C 1 8 ANB1-02 15 10 51 22 ANB1-01 22 81 25 18 35 93 30 21 94 107 46 24 175 133 50 41 462 190 74 41 612 230 74 60 871 271 86 70 1.2 or less 2.7 or less 3.8 or less 7.0 or less 12.0 or less 20.0 or less 32.0 or less 45.0 or less 1 4 ANB1-03 35 3 8 ANB1-04 60 1 2 ANB1-06 90 3 4 ANB1-10 160 1
) 258-9200-www.stevenengineering.com (3-NPT1/4) 3-Rc1/4 M5 x 0.8 Pilot port Breathing port M3 x 0.5 PB 13 46 PA 72 41 22.5 30 6.5 52.5 2-M5 x 0.8 Depth 6 20 17-5-26 24 Manually Operated Series LVH How to Order Valve (Single Type) VC Applicable tubing size Body class Body class 2 3 4 Connecting tubing O.D.
11 17 36 22.5 23 M5 8 26 64.5 48 62.5 62 60 50.5 103 62.5 70 107 1/4, 3/8 VCW41 30 50 94 41 13.5 17 36 25 23 M5 8 26 66.5 48 64.5 62 62 50.5 103 64.5 70 111.5 1/2 35 60 102 41 17.5 17 36 30 28.2 M5 8 26 70 48 68 62 65.5 50.5 103 68 70 119 3/4 17-2-55 8 Series VCW Dimensions (N.O.)
Nvv3zs-4lc-)-aF) 2-o1r irw3zs4rR-o2-o Applicau Yalng .NW3Z5-41-O2-e) NVzsl4-OOO NVZ5l4M-OOO .NW3Z5-4rR-O2-O NVz5:4R-OOO r{w3zs-41-o2-o ; -*o** E]2 stations :r{29.1 20 stations BLnk p|.le.3ty DXT201-15-1A lfthere are more lhan I siations, supply air and exhaust lrom bolh sides ol manitold, @ W,:f;::W#ffinaidvqhre' Blank PlateAss'g DXT20-1s-1A Apelic*b b..e . NW3Z'2GOI . NWSZ+2l-e)l .
590 AMV 3/4 200 72 74 41 710 1 200 72 74 41 605 AMP 1 200 72 74 41 725 1 230 72 74 41 665 1 230 72 74 41 810 11/4 240 72 74 54 765 11/4 240 72 74 54 910 11/2 240 72 74 54 790 11/2 240 72 74 54 935 609 5.0 MPa 5.0 MPa Applications included air-blowing, charging fluid into a vessel, or discharging (Blow-molding equipment, etc.)
Return to origin . 41 8.1 Return to origin . 41 8.2 Positioning operation . 41 8.3 Pushing operation. 42 (1) Pushing operation is successfully performed. . 42 (2) Pushing operation is failed (pushing the air) . 42 (3) Movement of the work piece after the completion of the pushing process .. 42 8.4 Controller input signal response time . 43 8.5 Methods of interrupting operation . 43 9.
65 41 A 97 61 a 2 2 STX 34 22 " 66 42 B 98 62 b 3 3 ETX 35 23 # 67 43 C 99 63 c 4 4 EOT 36 24 $ 68 44 D 100 64 d 5 5 ENQ 37 25 % 69 45 E 101 65 e 6 6 ACK 38 26 & 70 46 F 102 66 f 7 7 BEL 39 27 ' 71 47 G 103 67 g 8 8 BS 40 28 ( 72 48 H 104 68 h 9 9 HT 41 29 ) 73 49 I 105 69 i 10 0A LF 42 2A * 74 4A J 106 6A j 11 0B VT 43 2B + 75 4B K 107 6B k 12 0C FF 44 2C , 76 4C L 108 6C l 13 0D CR 45 2D
Piping . 41 5-7. Operating environment . 41 5-8. Lubrication . 41 6. Maintenance or inspection . 41 6-1. Maintenance or inspection . 41 6-2. Replacement part . 42 6-3. Maintenance . 42 1 - Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
(mm) Rod end male threads a b c e f g h Bore size (mm) 20 11 15 M10 x 1.25 6 10 23 66 25 14 18 M12 x 1.25 6 12 26 71 32 21 25 M16 x 1.5 7 14 35 86 40 26 30 M20 x 1.5 7 19 40 95 50 31 35 M24 x 1.5 8 24 46 106 63 41 45 M30 x 1.5 9 30 58 125 80 56 60 M39 x 1.5 14 41 77 155 100 71 75 M48 x 1.5 21 50 101 197 7 Series CHKDB Auto Switch Specifications Auto Switches: Proper Mounting Positions and
Rod end male threads (mm) Bore size (mm) a b c e f g h 20 11 15 M10 x 1.25 6 10 23 66 25 14 18 M12 x 1.25 6 12 26 71 32 21 25 M16 x 1.5 7 14 35 91 40 26 30 M20 x 1.5 7 19 40 105 50 31 35 M24 x 1.5 8 24 46 116 63 41 45 M30 x 1.5 9 30 58 135 80 56 60 M39 x 1.5 14 41 77 165 100 71 75 M48 x 1.5 21 50 101 207 19 Series CHKGB Auto Switch Specifications Auto Switches: Proper Mounting Positions