Refer to "Replacement Actuator (Cylinder)" on page 11 about how to order . 2.
1, @2 and @6 each. 12 MXY12-PS 8-9-11 11 Series MXY Dimensions 2-M5 x 0.8 Piping port J + Stroke Same in case of the type of centralized piping on one side without switch rail ( ) JH Piping port (Plug: M-5P) 2-M5 x 0.8 (Plug: M-5P) 2-M5 x 0.8 Piping port FL 21 21 FH 2-M thread depth MM +0.03 0 Width across flats MB (lock plate fixing bolt) R 4-M thread depth MM PR RL PR +0.03 0 MA (Stroke
Monitor and Test Mode of the Controller . 51 11. Operation . 53 11.1 Return to origin position . 53 11.2 Positioning operation . 55 11.3.
Description Side cover Bearing retainer Bumper End cover A End cover B Inner cover Motor cover R Motor cover L Auto switch Magnet Brake Material Note 100W Ball screw/Slide screw 1 2 3 4 5 6 7 8 9 10 11 No.
x Rc 1/8 (P port) 2 x Rc 1/8 (P port) Pg7 n1 x Rc 1/8 (A port) 2 x 4.5 (Mounting hole) 2A 2A 2A 35 19 (Pitch) 44.5 11 (Station 1) (Station n) (Pitch) n x Rc 1/8 (R port) L Dimension n L n: Stations 1 38 27 2 57 46 3 76 65 4 95 84 5 114 103 6 133 122 7 152 141 8 171 160 9 190 179 10 209 198 11 228 217 12 247 236 13 266 255 14 285 274 15 304 293 16 323 312 17 342 331 18 361 350 19 380 369 20
Auto drain IDK Port size Weight R2 245 R2 1/2 270 DIN flange 80 350 R2 245 R2 1/2 270 DIN flange 80 350 kg AMG Body panel: White 1 Base: Gray 2 Coating color AFF Compliant standards EC Directive compliant (with CE marking) Note 1) Air flow capacity under the standard condition (ANR) [atmospheric pressure 20C, relative humidity 65%] Note 2) Air flow capacity converted by the compressor intake
. *3 The travel distance of the actuator per 1 pulse should be 10 [m/pulse]. 11 - LECSC LEFB25 LEFB25U LEFB32 LEFB32U LEFB40 LEFB40U Lead symbol S Series Lead 54 Parameter Para. No.
-57 58 Series ZP Vacuum Pad/Components Refer to page 13-11-62 to 13-11-64 for part numbers of e to y.
Maximum manufacturable stroke (mm) Bore size (mm) Standard stroke (mm) 10 50, 100, 150, 200, 250, 300 500 15 50, 100, 150, 200, 250, 300, 350, 400, 450, 500 750 25 100, 150, 200, 250, 300, 350, 400, 450, 500, 550, 600 1200 The stroke is available in 1 mm increments with the maximum stroke as the upper limit. For a stroke in the standard stroke range, suffix the part number with -XB10.
AM Misc. 14-18-11 12 Series IDUS/IDFS Specific Product Precautions 2 Be sure to read before handling. Protection Circuit Time Delay for Restarting Caution Caution When the air dryer is operated under the following conditions, the protection circuit is activated, the light goes off and operation stops. Allow at least three minutes before restarting the dryer.
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Piping directions Maximum stroke Cushion Bore size (mm) Model Height Overall length mm mm 150 200 250 300 350 400 450 500 550 600 50 100 CX 10 15 25 15 10 25 240 350 310 For 100mm stroke cylinder Series Series 10 500 CY1F CY1H CY1F CY1H MY2H Concentrated
12 11 12 10 11 11 12 11 11 6.3 6.8 12 12 12 12 10 11 10 10 11 11 6.5 6.8 0.18 0.15 0.18 0.15 0.18 0.18 0.16 0.15 0.22 0.22 2 position 3 position 40 or less 0.63 1,000 Single VFS4100 1 2 VFR 3 8 15 or less 0.75 Double VFS4210 VFS4200 1,200 1 2 3 8 1 2 3 8 1 2 3 8 1 2 VP4 Closed center Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650
M4 x 0.7 21 10 GKM4-8 4 8 16 4 8 8 11 M4 x 0.7 21 12 GKM6-12 6 12 24 6 12 10 18 M6 x 1 31 16 GKM6-12 6 12 24 6 12 10 18 M6 x 1 31 20 GKM8-16 8 16 32 8 16 14 23 M8 x 1.25 42 25 GKM10-20 10 20 40 10 20 18 27 M10 x 1.25 52 Bore size Part no. b1 b3 dH7 d6 d7 h l l3 d3 a 8 KJ4D 8 6.0 5 18 11 27 10 10 M4 x 0.7 13 10 KJ4D 8 6.0 5 18 11 27 10 10 M4 x 0.7 13 12 KJ6D 9 6.75 6 20 13 30 12 11 M6 x 1
10.5 D-Z7/Z80 7.5 8.5 7.5 9.5 9.5 10.5 D-A5/A6 9 9 10 11 11 11 D-A59W 13 13 13 14 14 15 D-A3/A44 9 9 10 11 11 11 *1 The switch mounting bolt is supplied with the switch. * Values which include hysteresis are for reference purposes only.
point L (mm) Gripping point L (mm) Internal Grip MHZJ2-10D/11-MHZ2-10D MHZAJ2, MHZJ2, 11-MHZ2 Pressure 0.7 MPa Pressure 0.7 MPa 25 0.6 MPa 0.6 MPa 20 Gripping force (N) 0.5 MPa 0.5 MPa 15 0.4 MPa 0.4 MPa 0.3 MPa 0.3 MPa 10 L 0.2 MPa 0.2 MPa 5 0 10 20 30 40 50 60 Gripping point L (mm) MHZJ2-16D/11-MHZ2-16D Pressure 0.7 MPa Pressure 0.7 MPa 60 0.6 MPa 0.6 MPa 50 Gripping force (N) 0.5 MPa
of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Gripping point L (mm) Gripping point L (mm) MHS MHZJ2-10D/11-MHZ2-10D External Grip MHZAJ2, MHZJ2, 11-MHZ2 MHC 20 Gripping force (N) Pressure 0.7 MPa Pressure 0.7 MPa MHT 15 0.6 MPa 0.6 MPa 0.5 MPa 0.4 MPa 0.3 MPa 0.2 MPa 0.5
70 170 69 70 95 87 11 3 100 88 196 96 83 110 114 11 3 117 90 235 131 102 130 134 11 3 154 108 300 112 153 180 190 11 3 200 138 315 Note 1) Dimension E applies when heater option is included.
13 7 6 9 8 11 10 3 Connector B terminal no.