D. holding MHK2 series MHK2-16D MHK2-16D 50 50 Pressure 0.6MPa Pressure 0.6MPa 40 40 Holding force N Holding force N 0.5MPa 0.5MPa 30 30 L L 0.4MPa 0.4MPa 20 20 0.3MPa 0.3MPa 10 10 0.2MPa 0.2MPa 0 0 10 20 30 40 50 60 10 20 30 40 50 60 Holding point L mm Holding point L mm MHK2-20D MHK2-20D 80 60 70 Pressure 0.6MPa Pressure 0.6MPa 50 60 Holding force N Holding force N 50 40 0.5MPa 0.5MPa 40
If vibration is applied, malfunction or setting errors may result. 14-4-50 33 F.R.L.
If vibration is applied, malfunction or setting errors may result. 14-4-50 33 F.R.L.
1.25 43.5 27 5.5 28.5 36 32 6.8 to 11.3 277 3/8 201.5 25.4 22 M33 x 2.0 47.3 41 M14 x 1.5 52.5 30 7.5 23 32 40 50 to 100 Rc P EA Rc P EA GA NE 8-J GA WH ND H1 MM I D E E Effective thread K FA JC JC FB A NF C H S + Stroke B ZZ + Stroke H 50 0.042 GA 80 FB 16 FA 10 EA 23 D 62 C 20 A B 53 E Bore size (mm) Stroke range (mm) Eff. thread length 50 35 70 32 Up to 1200 0 63 80 16 10 23 58 20 60
60 75 100 50/6 3 25/3 Nil P R None (Standard) 5 With fitting for purge air discharge 10 20 30 50 60 75 100 100/11 200/22 300/35 500/60 600/65 750/80 1000/110 Flow direction (Right Left) With dew point indicator S Standard equipment Note) In the case of two or more options, indicate them alphabetically.
22 (37) 0 (15) 16 D-M9, D-M9V 10 (17) 0 0 32 37 (49) 22 32 (39) 5 (17) D-F9W, D-F9WV 10 (17) 0 0 32 37 (49) 22 32 (39) 5 (17) D-A9, D-A9V 0 (15) 0 0 38 38 (53) 26 26 (41) 0 (15) 20 D-M9, D-M9V 10 (17) 0 0 38 38 (55) 26 36 (43) 0 (17) D-F9W, D-F9WV 10 (17) 0 0 38 38 (55) 26 36 (43) 0 (17) D-A9, D-A9V 0 (15) 0 0 40 40 (55) 32 32 (47) 0 (15) 25 D-M9, D-M9V 15 (17) 0 0 40 50 (57) 32 47 (49)
-01-06 AS2200-01 AS2201F -01-08 AS2200-01 70% 100 SYJ 200 50 SX 100 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 10% 30% 50% 70% 50% 30% 10% 0 0 200 CM2 25 400 MB 40 150 300 Stroke (mm) Stroke (mm) AS2201F -01-06 AS2200-01 AS2201F -02-08 AS2200-02 100 200 50 100
size Model 11-/22-CXS6 6 11-/22-CXS10 11-/22-CXS15 11-/22-CXS20 11-/22-CXS25 11-/22-CXS32 10 15 20 25 32 10, 20, 30, 40, 50 Vacuum suction type Relief type M5 x 0.8 10, 20, 30, 40, 50, 75, 100 1/8 Double acting (Both sides) Non-lube 10-/12-/21-CXS6 6 single rod 10-/12-/21-CXS10 10-/12-/21-CXS15 10-/12-/21-CXS20 10-/12-/21-CXS25 10-/12-/21-CXS32 10, 20, 30, 40, 50 10 15 20 25 32 M5 x 0.8
Output type Current consumption PF3W721--A(-M) NPN open collector output 50 mA or less Flow switch SMC PF3W721--B(-M) PNP open collector output 50 mA or less 3.3 Installation HRSH Series 3-22 HRX-OM-Q026 Chapter 3 Transport and Setting Up 1. Prepare the flow switch described in the Table 3-9 (sold separately). 2.
(inch) Weight (g) Model d L M2 M1 Applicable tubing Applicable KQ2N01-03 KQ2N01-05 KQ2N03-05 KQ2N03-07 KQ2N05-07 KQ2N05-09 KQ2N07-09 KQ2N07-11 KQ2N09-11 KQ2N09-13 KQ2N11-13 36.5 37 37.5 38 38.5 41 41.5 45 46.5 47.5 50 16 16.5 16.5 17 17 18.5 18.5 21 21 22 22 0.2 0.4 0.4 0.6 0.6 1 1 1 11 22 24 5 32 15.5 2.2 1 8 tubing 3 16 3 16 5 32 16 2.5 1 4 1 4 16.5 3.5 3 16 5 16 5 16 1 4 17 4.6 3 8 3
CG-020-24A CG-025-24A CG-032-24A CG-040-24A CNG-020-24 CNG-025-24 CNG-032-24 CNG-040-24 28 28 28 30 42 42 48 56 20 25 32 40 38.3 42.1 53.8 64.6 28 28 28 30 16 20 22 30 42 42 48 56 35.8 39.8 49.4 58.4 18.1 20.7 23.6 27.3 3.2 3.2 4.5 4.5 13 15 17 21 26 28 28 36 50 57 61.4 71.4 47.8 54.8 57.4 65.4 21.2 21.3 25.6 26.3 3.2 3.2 4.5 4.5 13 15 17 21 20 25 32 40 Knuckle Pin Rod End Nut Clevis Pin
Weight (g) Auto switch model D-F6N D-F6P D-F6B 20 0.5 m (Nil) 19 3 m (L) Lead wire length 53 50 5 m (Z) 80 75 Dimensions (mm) D-F6 D-F6B 8.5 (22) 3.2 Indicator light (24) 16 Most sensitive position 7 2.7 10.6 7 29 D-F6N/F6P DD(22) 3.2 Most sensitive position 7 1609 Solid State Auto Switch with Timer Band Mounting Style D-G5NT RoHS Refer to SMC website for the details of the products conforming
20 10 5 7 10 M5 x 0.8 32 17 7.5 13 16.5 M8 x 1.25 40 22 9.5 13 16.5 M8 x 1.25 50 22 9.5 13 16.5 M8 x 1.25 Stroke KD KC KE O1 thread B + Stroke R R KA KB KE * Dimensions other than those shown above are the same as the drawings above.
Hastelloy C-22 Hastelloy C-22 PCTFE 80 0.55 316 SS PCTFE (Option: Vespel) 70 0.48 Delivery pressure (MPa) Delivery pressure (psig) 60 0.41 Dimensions inch (mm) 50 0.34 AK1400T 40 0.28 30 0.21 2.12 (53.8) 20 0.14 10 0.07 Max. 5.6 (142.2) Max. 6.0 (152.4) (When selecting option code P or BP) 0 0.00 0 100 200 300 400 500 600 700 800 Flow rate (slpm, N2) AK1400T 80 psig (0.55 MPa) Inlet pressure
Bore size (mm) 6 10 Content CYR 15 E CYR 6ENos.18, 19, 22, 27 at the left CYR10ENos.18, 19, 20, 22, 27 at the left Note 2) Nos.17, 18, 20, 22, 27 at the left 15 CYR15EStroke CYR20EReed switch 20 Solid state switch CYR20EN25 32 40 50 63 Bore size CYR25ENos. CYR32E17, 18, 19, 20, 22, 27 CYR40Eat the left CYR50ECYR63ENote 1) indicates the stroke.
HRS012/018--10-T/MT HRS012/018/024/030--20-T HRS012/018/024/030--20-MTNote 1) Applicable model Rated flow50/60Hz Note 2) 3) 7(0.36MPa)/10(0.42MPa) 10(0.44MPa)/14(0.40MPa) 10(0.32MPa/)/14(0.32MPa) Pump 18/22 Maximum flow rate (50/60 Hz) L/min Maximum pump head (50/60 Hz) m 55 70 60 Output W 320 550 Circuit protector 15A (10 A for standard) A 15 Recommended earth leakage breaker capacity 15
Dimensions [mm] Model L1 L2 A B C D E F G J K LEPS10-25 138 152.5 61.8 20 22 30 29 20 29 39 88.2 LEPS10-50 163 177.5 24 43 34 50 24 50 60 113.2 LEPS10L-25 124 138.5 47.8 20 22 30 29 20 29 39 88.2 LEPS10L-50 149 163.5 24 43 34 50 24 50 60 113.2 394 LEPY/LEPS Series Specific Product Precautions 1 Be sure to read this before handling the products.
40 11 12 6.6 41 54 10 24 9 22 28 35 36 10 11 50 15 12 9 50 65 12 33 11 30 32 45 45 12 12 63 15 16 9 52 67 14 37 11 35 40 50 50 12 15 80 18 16 11 66 86 18 47 12.5 40 50 60 63 14 15 100 18 20 11 76 96 20 55 13.5 50 60 70 71 15 19 Mounting type CR Rear clevis with ball joint A B C D EN ER F G E L M N P H R (mm) 0.2 maxi JS15H7 -0.1 maxi H11 H13 H13 0.5 0.5 0.5 32 32.5 10.5 22 10 14 15 30 10
Function 1 2 3 4 5 6 100VAC (50/60Hz) 200VAC (50/60Hz) 110VAC (50/60Hz) 220VAC (50/60Hz) 24VDC 12VDC Standard type (1W) Energy saving type (0.5W) External pilot Nil Y Note 1) Seal type R Note 2) Metal seal Rubber seal 0 1 1 2 3 Stations D side U side Note1) Applicable to DC specifications. Note2) See page 35 for details on external pilot specifications.
22 6.6 8.6 8.6 1/8 1/4 1/4 18 38 47 55 30 40 50 104 200 200 200 44 60 70 11 14 14 13 9 14 118 146 158 7.5 9 9 24 24 28 86 110 124 106 130 142 48 48 52 72 92 110 300 300 300 40 50 63 M8 x 1.25 M8 x 1.25 21.5 130 M10 x 1.5 M10 x 1.5 28 130 M10 x 1.5 M10 x 1.5 WB Bore size (mm) X XA XB YY YL Z XC XL st25 25