Type: 001 (Smart Lever Type), Pressure Gauge: 3 (1.0 MPa), Accessories: None (Standard), External Scale Plate: None, LCD Window: None, Connection, Air - Electric: M (Rc1/4 - M20x1.5)
Type: 001 (Smart Lever Type), Pressure Gauge: 3 (1.0 MPa), Accessories: None (Standard), External Scale Plate: None, LCD Window: W (Body w/LCD Window)
Type: Relay Device, Type: Smart lever type, Specification: With Intrinsically safe explosion-proof (ATEX) + Output function + HART communication function, Pressure(MPa): 1.0, Fork lever type fitting: N/A, Lever unit: N/A, External scale plate: N/A, Body cover with window for LCD: N/A, Air connection port: Rc1/4, Conduit connection port: M20 × 1.5, Explosion-proof structure: ATEX Directive
Type: Relay Device, Type: Smart lever type, Specification: With Intrinsically safe explosion-proof (ATEX) + Output function + HART communication function, Pressure(MPa): 1.0, Fork lever type fitting: N/A, Lever unit: N/A, External scale plate: N/A, Body cover with window for LCD: Available, Air connection port: Rc1/4, Conduit connection port: G1/2, Explosion-proof structure: ATEX Directive
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, POSITIONER, INSTRUMENTATION, IP8000/8100 POSITIONER, 2A, IP8000/8100 NO SIZE PT VERSION, 9.03895 lb
Electro-Pneumatic Positioner, POSITIONER, 805, 2.60000 lb
Check the occupied bytes of the EX600 I/O unit and valve manifold connected to the remote. (3) Confirm that there is no loose connection units. between the units and connect them correctly. (3)-1 Abnormal digital input unit. (3)-2 Abnormal digital output unit. (3)-3 Abnormal digital input/output unit. (4) Check the part where the error occurs by MS: Red LED flashes. (4) EX600 I/O unit detects
System diagnostic status1 7 6 5 4 3 2 1 0 Byte 1 Bit No.
: EX600-SPN (32 coils Status) ---4 4 (1) (2) (3) (4) -61No.EX-OMQ0015CN (1)[HW Config]EX600-SPN#[Configuration table][ ][Properties] (2)[Parameters] (3)[Value] (4)[OK]PLC (1) (1) (2) (2) (3) (4) (3) -62No.EX-OMQ0015CN FSU(First Start Up) EX600FSU FSUPLCFSU PLC (1)[HW Config]EX600 PLC PROFINET [Properties] (2)[Options] (3)[Connection][TP 100Mbps full duplex] (4)[Disable autonegotiation]
(BUS IN/OUT) Fig. 3-5 Pin allocations of PROFINET communication connectors Note: when the autonegotiation function is disabled, you must use the correct network cable, refer to Fig 3-6, 3-7, 3-8.
The setting when shipped from plant is turned OFF, set to HW mode. 1 (No.1) 2 (No.2) 4 (No.3) 8 (No.4) 16 (No.5) 32 (No.6) MAC ID 0 OFF OFF OFF OFF OFF OFF No.10 Function Mode 1 ON OFF OFF OFF OFF OFF HW OFF Set MAC ID and baud rate with SW1 to 8. 2 3 OFF ON OFF OFF OFF OFF SW MAC ID and baud rate are set by network. : SW1 to 8 are ignored.
Refer to "Operation Manual" for detail. 2 3 4 OFF OFF OFF OFF OFF ON OFF OFF OFF OFF OFF OFF ON ON HW/SW mode setting (switch No.10) OFF OFF OFF OFF ON OFF OFF The setting is as follows.
Description No.1 Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: +81 3-5207-8249 Fax: +81 3-5298-5362 0 HW Set the address and speed in a local with switch on the SI unit Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.
HW 0 No. Element Description Factory default setting is HW mode. The MAC ID and communication speed will be retained if the unit is powered off and software mode is selected (DIP switch 10). If HW mode is selected then the settings stored using SW mode will be replaced by the HW settings. Note Ground the FG terminal with a ground resistance of 100 or less.
Class common service Service code Description 0Eh Get_Attribute_Single -23No.EX-OME0015-F 3-3.
[June 2022] 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021 JAPAN Tel: + 81 3 5207 8249 Fax: +81 3 5298 5362 URL https://www.smcworld.com Note: Specifications are subject to change without prior notice and any obligation on the part of the manufacturer. 2011-2022 SMC Corporation All Rights Reserved No.EX-OMO0030-E
Input setting (Switch No.1 to 3) The setting at shipment is turned OFF, set to 64.
change over switch x10 x1 Address setting switch Grounding terminal (FE) Used for grounding. 7 7 7 1 5 1 3 3 7 3 5 7 SI unit side 3 These safety instructions are intended to prevent hazardous situations and/or equipment damage.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, POISTIONER, INSTRUMENTATION, IP8000/8100 POSITIONER, 2A, IP8000/8100 NO SIZE PT VERSION, 6.80886 lb