L n 2 5 6 7 8 9 10 4 3 Internal Pilot Manifold L Dimension n: Stations L n 2 5 6 7 8 9 10 4 3 External Pilot Manifold L Dimension n: Stations L1 L2 L3 L4 L1 L2 L3 L4 98 87.5 70 14 110.5 100 80.5 15 123 112.5 91 16 135.5 125 101.5 17 135.5 125 112 12 148 137.5 122.5 13 160.5 150 133 14 173 162.5 143.5 15 185.5 175 154 16 110.5 100 80.5 15 123 112.5 91 16 135.5 125 101.5 17 135.5 125 112 12
L4 L1 L2 L3 L4 L n 12 260.5 250 229 16 L n 12 273 262.5 239.5 17 10 235.5 225 208 14 11 248 237.5 218.5 15 13 273 262.5 239.5 17 14 285.5 275 250 18 15 285.5 275 260.5 12.5 16 298 287.5 271 13.5 10 248 237.5 218.5 15 11 260.5 250 229 16 13 285.5 275 250 18 14 285.5 275 260.5 12.5 15 298 287.5 271 13.5 16 310.5 300 281.5 14.5 L1 L2 L3 L4 L1 L2 L3 L4 33 3 Station table entries In the case
L4 L1 L2 L3 L4 L n 9 223 212.5 197.5 13 L n 9 235.5 225 208 14 10 235.5 225 208 14 11 248 237.5 218.5 15 12 260.5 250 229 16 13 273 262.5 239.5 17 14 285.5 275 250 18 15 285.5 275 260.5 12.5 16 298 287.5 271 13.5 10 248 237.5 218.5 15 11 260.5 250 229 16 12 273 262.5 239.5 17 13 285.5 275 250 18 14 285.5 275 260.5 12.5 15 298 287.5 271 13.5 16 310.5 300 281.5 14.5 L1 L2 L3 L4 L1 L2 L3 L4
[mm] L3 [mm] L3 [mm] L3 [mm] 600 600 L3 25A1000 1000 Z 400 400 500 500 LEC 200 200 0 0 0 0 LEC S 0 10 5 15 20 0 10 5 15 20 30 25 0 10 40 50 20 30 0 10 40 50 20 30 60 70 80 Work load [kg] Work load [kg] Work load [kg] Work load [kg] LEC SS-T 5000 mm/s2 or less is same as 5000 mm/s2 5000 mm/s2 or less is same as 5000 mm/s2 5000 mm/s2 or less is same as 5000 mm/s2 5000 mm/s2 or less is same
IN OUT Table of UL-compliant Products JSXD Series JSXZ Series JSXM Series Option Replacement Parts D C B A Applicable air combination model A B C D AC20-D 41.6 43.2 126.4 60.12 AC30-D 55.1 57.2 167.4 73.01 AC40-D 72.6 75.2 220.3 77.01 Combination example w L2 L3 (L3) (L3) L1 Modular mounting type 2-port solenoid valve JSXM21-AN301R-5G-U 4 pcs. Spacer with bracket Y200T-D 3 pcs.
Number of mounting holes (N) = (L3/12.5 + 1): Decimal fractions are truncated DIN rail overall length (L1) = N x 12.5 + 23 [mm] Mounting screw length (L2) = L1 10.5 [mm] Rail length on one side (L4) = (L1 L3)/2 [mm] C1 Value Selection Separate wiring type 45 33 A NA Connector box type 4586 D-sub connector 25 pin type 45F 45P Flat cable type 54 Courtesy of Steven Engineering, Inc.-230 Ryan
Applicable shaft type: W (mm) Y L2 L2 max Size (mm) E3 = E1 = Y = 10 3 to 8 5 ( 8 Y) to (Y 1) Y-1 L1 L3 max X Size L2 = L4 = 10 9 (14 X) to (X 1) 15 3 to 9 6 ( 9 Y) to (Y 1.5) Y-1.5 3 to 14 X 1 L1 = 15 10 (18 X) to (X 1.5) 20 3 to 10 7 (10 Y) to (Y 1.5) Y-1.5 3 to 18 X 1.5 L3 = X = 20 10 (20 Xs) to (X 1.5) 30 5 to 13 8 (13 Y) to (Y 2) Y-2 3 to 20 X 1.5 30 12 (22 X) to (X 2) 40 7 to 15 9 (
Auto Switch Made to Order 62 C75 Series Dimensions of Accessories Rod End dH7 45 d3 b1 b3 l l3 d7 d6 h [mm] Bore size Part no. b1 b3 dH7 d6 d7 h l l3 d3 a 32 KJ10DA 14 10.5 10 28 19 43 20 15 M10 x 1.5 13 40 KJ12DA 16 12 12 32 22 50 22 17 M12 x 1.75 13 Floating Joint: JA M M U U D F G H B P E A [mm] Bore size Part no.
Cylinder: MXQ16-50 Cushion: Rubber stopper Workpiece table mounting Mounting: Horizontal wall mounting Average speed: Va = 300 [mm/s] Load weight: W = 1 [kg] L1 = 10 mm L2 = 30 mm L3 = 30 mm Kinetic Energy L1 L2 + A5 L3 2 1 V 2 E = W () 2 1000 Collision speed V = 1.4Va Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside
Size 20, 30, 40 Size 10, 15 L3 = (mm) L1 = X = Applicable shaft type: W Equal dimensions are indicated by the same marker.
Allowable Moment (Nm) Allowable dynamic moment LTF6 Model Mounting orientation Load movement direction 200 L1 (mm) L3 (mm) Pitching Rolling Vertical Vertical 100 m a a=1000 a=2000 a=3000 L1 Mep 0 6 4 2 Transfer load m (kg) 200 100 a=1000 a=2000 a=3000 a L3 Mey 6 4 2 0 Transfer load m (kg) m : Transfer load (kg) a : Work piece acceleration (mm/s2) Me: Allowable dynamic moment L : Overhang
[mm] L3 [mm] L3 [mm] L3 [mm] 600 600 L3 25A1000 1000 Z 400 400 500 500 LEC 200 200 0 0 0 0 LEC S 0 10 5 15 20 0 10 5 15 20 30 25 0 10 40 50 20 30 0 10 40 50 20 30 60 70 80 Work load [kg] Work load [kg] Work load [kg] Work load [kg] LEC SS-T 5000 mm/s2 or less is same as 5000 mm/s2 5000 mm/s2 or less is same as 5000 mm/s2 5000 mm/s2 or less is same as 5000 mm/s2 5000 mm/s2 or less is same
Step 3 Check the guide moment. 1500 1000 mm/s2 Overhang: L3 [mm] Mep 1000 m 3000 mm/s2 L3 500 5000 mm/s2 0 Based on the above calculation result, the LEFSl40lB-200 is selected. 0 10 20 30 40 50 60 Work load [kg] 784 Model Selection LEFS Series Motorless Type * The values shown below are allowable values of the actuator body.
Width across flats MG MB series MN (mm) Bore size (mm) MG 17 19 24 24 27 32 MH 44 48 53 53 72 75 MI 23 32 38 38 45 55 MK 9 10 13 13 14 17 ML 20 22 24 24 32 35 MN M8 x 1.25 M10 x 1.25 M14 x 1.5 M14 x 1.5 M16 x 1.5 M20 x 1.5 ZZ 175 183 205 205 258 261 32 40 50 63 80 100 MI MK 4 H1 ML + Adjustment Stroke MH + Stroke + Adjustment ZZ + 2 x Stroke + Adjustment (A: 25 mm, B: 50 mm) Width across
Load (kg) Note: 1 Nm = 0.7375 ftlb 1 kg = 2.2046 lb 1 in = 25.4 mm W1 W W m Moment (Nm) M = F x L M = F x L M = F x L F3 F2 F1 L2 L1 L3
A3 Mp Mr Static moment Dynamic moment My W W W L2 A2 L3 A3 L1 A1 Mp Mr My W W W W Mey Mep We We L3 A3 L2 A2 W Note) It is not necessary to consider load factor when using this device vertically perpendicular.
Mep Mep = 1/3 We x 9.8 (L3 + C) Examine Mep.
Size 20, 30, 40 Size 10, 15 L3 = (mm) L1 = X = Applicable shaft type: W Equal dimensions are indicated by the same marker.
35.5 59.6 [66.6] Approx. 300 (Lead wire length) 62.8 [65] 53 [55.2] 61.9 54.5 48 Refer to the page 68 for dimensions with connector cable.
Load mass (kg) m1 m2 Moment (Nm) m3 M3 = F3 x L3 F3 F2 M1 = F1 x L1 F1 M2 = F2 x L2 L2 L1 L3 Calculation of Guide Load Factor 1) Maximum load mass (1), static moment (2), and dynamic moment (3) (at the time of impact with stopper) must be examined for the selection calculations. To evaluate, use a (average speed) for (1) and (2), and (collision speed = 1.4a) for (3).