-06 AS321F-03-07 6 1/4" 12.8 17 27.8 39.3 27.8 55 39.3 17 55 13.2 AS321F-03-08 AS321F-03-09 8 5/16" 15.2 18.5 29.5 41 23 29.5 57 41 18.5 57 19.8 45.4 40.4 40.2 35.2 15.2 3/8 45.4 40.4 40.2 35.2 19.8 23 3/8 AS321F-03-10 AS321F-03-11 31.8 43.3 21 59 17.9 10 18.5 21 43.3 31.8 59 3/8" AS321F-03-12 AS421F-04-11 12 3/8" 20.9 22 44.3 32.8 33.6 61 47.9 21 100 17.9 24 28.6 49.2 49.6 42.1 1/2 24.5
VALVE TYPES AVAILABLE To operate a solenoid pilot valve in a vacuum s y s t e m , a s e p a r a t e p r e s s u r e s u p p l y m u s t b e s u p p l i e d t o t h e v a l v e t o m o v e t h e s p o o l o r p o p p e t a s d e s c r i b e d a b o v e .
M a n i f o l d m o u n t e d v e r s i o n s o f t h e V YH y r e g a r e a v a i l a b l e .
Able to control and set a constant speed easily.
13 9 5 Symbol 2 1/4 Nil 02 03 0.05 to 0.65MPa 1 3/8 2 1/4 2 0.1 to 0.9MPa 2 02 03 04 03 04 06 1/4 3/8 1/2 3/8 1/2 3/4 1 2 3 4 3/8 03 04 06 3 1 30 3/8 0.005 to 0.15MPa 1 4 1/2 4 45 1 3/4 12 8 4.5 2.5 Without sub-plate Nil 02 03 1(P) Symbol Flow type (VEF2) Flow type (VEF3) Pressure type (VEP3) 2 2(A) 1/4 3 3/8 2(A) 2(A) 1(P) 3(R) 1(P) 3(R) 03 04 06 25 3/8 1/2 3/4 1 4 Note) Does not conform
D D 10 14 B B 24 31 A 8 11 A 7 10 Model ZP3-T035U;K3-B3 ZP3-T035U;K6-B3 Note) ;in the table indicates the pad material "N, S, U, F, GN, GS."
A bit can have a value of 1 or 0. Branch A bus topology term used to describe a drop off the trunk line. Bus A group of lines used for data transmission or control. Bus Topology The physical layout of the nodes and the interconnecting physical media. Bus line Any type of wires that carry data from node to node.
Table(2) Rated Voltage-Electrical Entry-Electrical Option PAX Table(1) Connection Size and Applicable Model Insulation type Electrical entry Electrical option 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) Class B Class H G C D, T G, C T PB S L, Z S L, Z S Note ) Connection Applicable model VXP2130-02 VXP2130-03,VXP2140-03 VXP2130-04,VXP2140-04 VXP2150-06
(2) Model d T Weight (g) H D1 D2 L1 L2 L3 L5 (1) A (2) D3 L4 Max.
Note 3) Bowl assembly for AF30 to 60 models comes with a bowl guard (steel band material). 26 AF10 to 60 Dimensions L AF10, 20 AF50, 60 A G D Bracket (Option) L Bracket (Option) F D M G K K F M J J B E E B H OUT IN C OUT IN H C Port size OUT OUT Port size o s AF10: 25 AF20: 40 Drain A P Min. clearance for maintenance AF30, 40, 40-06 L Bracket (Option) A D G F M K J B E Drain Min. clearance
Step Data setting Note 2, 3) 06h / 10h Setting of a single or all Step Data parameter(s) Direct Operation Step Data reading 03h Reading of Direct Operation Step Data parameters. Direct Operation Step Data setting 06h / 10h Setting of a single or all Direct Operation Step Data parameter(s).
manifold along with the manifold base model no. 1 (P) 3 (R) 5 (R) 1 (P) 3 (R) 3 position exhaust center 3 position exhaust center (B) 2 (A) 4 (B) 2 (A) 4 (Example) SS5YJA3-41-03-M5 1 pc.
required flow rate to operate a 40 cylinder at a speed of 60mm/s is approximately 4.5l/min.
Stations S42R Type Coil is located on same side as the A port. 2 stations 02 Coil is located on same side as the A port. S ... ...
N.O. 0.4 0.3 0.2 0.1 0.2 0.3 0.4 0.5 0.6 Operating pressure (MPa) Flow Characteristics/Weight C [dm 3/(s bar)] b Cv C [dm 3/(s bar)] b Cv 1 2 (P A) 2 3 (A R) Valve model Flow characteristics Weight (g) Effective area (mm2) Pilot port size Type of actuation Port size SYJA312-M3 SYJA322-M3 SYJA314-M5 0.41 0.18 0.086 0.35 0.33 0.086 Body ported N.C. N.O. N.C.
Refer to 4.3.2 Setting and checking,5.3.2 Setting and checking. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Do not connect any wire to other PIN numbers.
Refer to 4.3.2 Setting and checking,5.3.2 Setting and checking. 2 2 R D R D 3 3 S D S D 5 5 S G S G Master This product Fig 3.3-2 RS-232C connector connection 3.3 Connected explanation HRSH Series 3-2 HRX-OM-R028 Chapter 4 MODBUS communication function Chapter 4 MODBUS communication function MODBUS protocol is a communication protocol developed by Modicon.
(Refer to Air-hydro type on page 238.) * Air-hydro cylinder: Rubber bumper only CM2 CM2 R CM2 A A 20 100 Z CM3 CG1 CDM2 A A R 20 100 With auto switch M9BW Z CG3 With auto switch (Built-in magnet) Number of auto switches JMB Rod end bracket Nil 2 pcs. S 1 pc. n n pcs.
or less 0.03 s or less 0.05 s or less 0.05 s or less Response time Hysteresis 3% F .S.