www.stevenengineering.com I 6.11 VACUUM VACUUM PADS SERIES ZP H O W T O O R D E R ZPT P A D V E R T I C A L T Y P E W I T H O U T B U F F E R ZPT V A C U U M E N T R Y ( A L S O M O U N T I N G T H R E A D D I A) P A D D I A M E T E R S Y M B O L T H R E A D D I A M E T E R 2~ 8 10~ 16 20~ 32 40 50 02 2 04 4 06 6 08 8 10 10 13 13 16 16 20 20 25 25 32 32 40 40 50 50 P A D M AT E R I A L Male
CE-compliant Valve mounting direction Stations R port Nil Pilot valve is opposite the A port side. 02 2 stations A A M5 x 0.8 Nil R port P R Q CE-compliant : : A A M5 x 0.8 A port M3 x 0.5 P port M5 x 0.8 Pilot valve is on the A port side. 20 S 20 stations P port M5 x 0.8 A port M3 x 0.5 Note) For more than 10 stations, supply air to both sides of P port and exhaust air from both sides of
(0.2 to 2.0 MPa) VBA11A-02 AR425 to 935 ARX 1/4" AMR ARM ARP VBA20A-03 VBA22A-03 IR-A IR IRV 3/8" VEX SRH SRP VBA42A-04 VBA43A-04 (0.2 to 1.6 MPa) VBA40A-04 SRF ITV 1/2" IC ITVH ITVX Air Tank VBAT Series PVQ P.1022 VY1 Perfect fit with a booster regulator VBA VBAT VBA VBAT This is an air tank to which a booster regulator can be connected compactly.
How to Order Sub-plate and Base Gasket Body size 22 42 VEX VEX VEX1 2 9 A VEX4 2A 1 A Port size Thread type Port size Thread type Symbol Port size A 1/8 B 1/4 Symbol Thread type Nil Rc F G N NPT T NPTF Symbol Port size A 1/4 B 3/8 C 1/2 Symbol Thread type Nil Rc F G N NPT T NPTF Sub-plate Base gasket VEX1 11 2 VEX4 4 Options/Part Number Description Part number VEX312-01 02 VEX322-01 02 VEX33202
A-q A-w A-e A-r A-t A-y A-u A-!1 A-y A-u A-!2 A-!
Model d T Weight (g) H D1 D2 L1 L2 L3 L4 A Max.
G A S K E T C O N S T R U C T I O N A g a s k e t m a d e o f s t a i n l e s s s h e e t c o v e r e d w i t h l a m i n a t e d N B R o n b o t h s i d e s i s s e a t e d o n t h e chamfer of a female thread to materialize a perfect sealing construction irrespective of the difference in thread diameters due to the difference in the types of female threads, variation in tolerance, difference
in Parentheses MECHANICAL VALVES DIMENSIONS Series NVM NVM121-N01-02 131-N01-02 NVMl21-N01-01 131-N01-01 f,-rgl1gtlr ?.
EX: NVM121-N01-01S NVM131-01-01 NVM131-01-35 NVMl51-01-35 NVMl21-01-02 NVM13t-01-02 NVM120-N01-00 130-N01-00 F.O.F.'lbs.
SYJA 2(A) 2(A) Standard VZA (P)1 3(R) (P)1 3(R) i VFA 2(A) 2(A) 2(A) 3(R) VFRA o For vacuum (P)1 3(R) (P)1 3(R) VPA4 SYJA X VZA 1(P) VTA For vacuum u y t r e w q VGA VPA VPA VPA3 i 2(A) 3(R) o X Component Parts No.
VVEX2-2-5-02 VEX1233-G VEX1-17 4 pieces 1 piece Set Pressure Characteristics (Air operated type) Set Pressure Characteristics (Manual handle type) A port pressure (MPa) A port pressure (MPa) Signal port PA Pressure (MPa) Handle rotation (Cycles) 14-6-5 6 Series VEX130 3 Flow Characteristics P port pressure: 1 MPa VEX1A33, VEX1B33-01 VEX1130 3, VEX1230 3-02 VEX1330 3-03 A port pressure (MPa
(1.8) 14.8 (0.8) 36 (2) 15.3 (0.85) 02 03 VFA5144 2 position single : 0.51 02 03 04: 0.56 34.2 (1.9) 34.2 (1.9) 33 (1.8) 36 (2) 45 (2.5) 52 (2.9) 02 03 04 1 8 3 8 1 2 1 4 , , : 0.52 02 03 04: 0.57 1 8 45 (2.5) 52 (2.9) VFA5244 2 position double 02 03 04 3 8 1 2 1 4 , , Body ported : 0.66 02 03 04: 0.71 VFA5344 -X1 3 position closed center 1 8 34 (1.9) 38 (2.1) 02 03 04 JIS Symbol 3 8 1 2
If a directional switching valve (solenoid valve, mechanical valve, etc.) is mounted on the supply side of the regulator and repeatedly switched ON and OFF, wear of the nozzle/flapper section will be accelerated and a discrepancy in the setting value may occur. Therefore, avoid using a directional switching valve on the supply side.
Operation of the cylinder with its body fixed will damage the wear ring, resulting in increase of particle generation or malfunction. 12-REA40 10-AS2001F-06-X214 10-AS2301F-02-06-X214 10-AS2201F-02-06-X214 12-REA50 10-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 12-REA63 10-AS3001F-08-X214 10-AS3301F-02-08-X214 10-AS3201F-02-08-X214 Although speed adjustment is possible with
4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 A 4 2-One-touch fitting (X, PE ports) Applicable tube O.D.: 6 2n-One-touch fitting (A, B ports) Applicable tube O.D.: 4 6 (L4) L3 (3.2) 113.7 U Side D Side 3.1 8 36.3 43.7 5.5 (DIN rail dimension) 35 18 28.8 DIN rail holding screw Manual override DIN rail ( ) In case of locking type, turn after pushing in.
B A HS 056 HS B A B A 075, 106 HS B A B A 150, 200, 250 Note 1) Figures in the table below are references for auto switch mounting positions in the stroke end detection.
Description AXT336-1A-1 01 02 01 02 01 02 02 03 02 03 02 03 02 03 Manifold block assembly AXT336-1A-2 AXT336-1A-3 AXT336-2A-1AXT336-2A-2AXT336-3A-1AXT336-3A-2q End plate (U side) assembly w End plate (D side) assembly e Terminal assembly Junction cover assembly Tie-rod r t y Replacement Parts No. u Description Material Carbon steel NBR NBR Part no.
Maintenance detection signal ON OFF Output Requirement for maintenance detected ON OFF Input External switch signal 1, 2 455 IZN10 Series Dimensions 06 07 06 07 Energy saving static neutralization nozzle/IZN10-01 High flow rate nozzle/IZN10-02 20 Note 1) (110) 16 100 5 5 46 A 3.4 18.5 11 6 5 6 A 8 7 (Tap for ground wiring) M3 x 0.5 depth 4 40 25 12 A 93.6 A-A (mm) A Model 01 02 01 02 IZN1006
No code A 1) Only available with AP501.
A side manual override: Orange A side passage symbol: Orange A B A B B side passage symbol: Green B side manual override: Green Pull the lever forward with a screw driver, etc.