Size: 1/8, Thread: NPT, Port Size: 1/4, Accessory: None, Option 1: None, Option 2: CZ [Bowl Guard (Size 2000 Only)+Name Plate, Caution on Bowl]
Size: 1/8, Thread: NPT, Port Size: 1/4, Accessory: None, Option 1: Drain Cock, Option 2: CRZ [Bowl Guard(Size2000 Only)+Flow Direction:Right->Left+Name Plate Caution on Bowl]
Size: 1/8, Thread: NPT, Port Size: 1/4, Accessory: None, Option 1: Drain Cock, Option 2: CZ [Bowl Guard (Size 2000 Only)+Name Plate, Caution on Bowl]
Size: 1/8, Thread: NPT, Port Size: 1/4, Accessory: None, Option 1: 36 [Drain Cock+Nylon Bowl (Including Sight Dome)], Option 2: CRZ [Bowl Guard(Size2000 Only)+Flow Direction:Right->Left+Name Plate Caution on Bowl]
Size: 1/8, Thread: NPT, Port Size: 1/4, Accessory: None, Option 1: 36 [Drain Cock+Nylon Bowl (Including Sight Dome)], Option 2: CZ [Bowl Guard (Size 2000 Only)+Name Plate, Caution on Bowl]
Size: 1/8, Thread: NPT, Port Size: 1/4, Accessory: None, Option 1: 36 [Drain Cock+Nylon Bowl (Including Sight Dome)], Option 2: Name Plate, Caution on Bowl
Body Size: 20, Thread: NPT, Port Size: 1/4, Mounting: None, Semi-Standard, Body Size 10: Standard, Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard
Body Size: 20, Thread: N (NPT), Port Size: 02 (1/4), Mounting: None, Semi-Standard, Body Size 10: Standard, Semi-Standard, Body Size 20: Standard, Semi-Standard, Body Size 30, 40, 50 & 60: Standard
I { 0 s l I l 6 l ; D.0 t' 6 l 0.6 0.5 o.4 0.3 6 ' ) !
D (for PA3000 automatically operated type) Discharge rate 5 0.040 125 (cycles/min) = = Cycles per minute Discharge per cycle Reference life cycles 1 1 = x x Service life Cycles per minute 8 (Daily operating time) 60 1 1 100,000,000 = x x 60 8 125 1666 days = 17-5-145 6 Series PA/PAX/PB Precautions 5 Be sure to read before handling.
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
10 to 60C (No freezing or condensation)Operating/Stored: 35 to 85% RH (No condensation)250 VAC for 1 minute between live parts and case2 M or more between live parts and case (at 50 VDC Mega)10 to 150 Hz at whichever is smaller of 1.5 mm amplitude or 20 m/s2 acceleration, in X, Y, Z directions, for 2 hours each (De-energized)100 m/s2 in X, Y, Z directions, 3 times each (De-energized)?
IS3000-02 IS3100 IS3010-02 IS3110 Standard 5 VDC 160 mA Z I SE3 Micro load 5 VDC 1 mA PS Easy electrical wiring Wide space for wiring. Fixed wiring possible with G 1/2 connector.
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Mounting: B (w/Bracket), Bowl: Polycarbonate Bowl, Lubricant Exhaust Port: w/o Drain Cock, Flow Direction: Left to Right, Pressure Unit: Z ( Pressure Unit: psi; Temp Unit: °F
Body Size: 20, Thread: NPT, Port Size: 1/8, Mounting: w/o Mounting Option, Bowl: Polycarbonate Bowl, Lubricant Exhaust Port: w/o Drain Cock, Flow Direction: Left to Right, Pressure Unit: Pressure Unit: psi; Temp Unit: °F