Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector),

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: M (0.35 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Vertical Connector w

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: M (0.35 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector),

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector

Nozzle Diameter: 20 (ø2.0mm), Vacuum Pressure: S (-89 kPa), SUP: F03 (Screw-in G 3/8), VAC: F04 (Screw-in G 1/2)

Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: P (Port Exhaust, Rc1, G1, NPT1), Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector),

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: MO (M Plug Horizontal Connector w/o Connector

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Vertical Connector w/o Connector),

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Vertical Connector w/Lead Wire 300mm

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Vertical Connector w/Lead Wire 300mm

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: B1 [Supply Valve (N.O.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Horizontal Connector w/Lead Wire 300mm

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)]

Suction Flow Rate: 600 L/min (ANR), Supply Pressure: H (0.50 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K2 [Supply Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Vertical Connector w/Lead Wire 300mm), Light/Surge Voltage

Suction Flow Rate: 300 L/min (ANR), Supply Pressure: M (0.35 MPa), Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: K1 [Supply Valve (N.C.), Release Valve (N.C.)], Rated Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Vertical Connector w/Lead Wire 300mm

Body Size: 6 (1/2 Basis), Port Size: F04 [Cylinder Side (R(PT)1/2) Pilot Port (G(PF)1/4)], Applicable Tube OD: Ø10

Body Size: 6 (1/2 Basis), Port Size: F04 [Cylinder Side (R(PT)1/2) Pilot Port (G(PF)1/4)], Applicable Tube OD: Ø12