Auto switch capable How to Order NC D A1 B 150 0400 + 0200 H XC11 R Mounting Bore size Auto switch Stroke B-A Dual operationSingle rod Stroke A Cushion Both ends N W/o cushions H Head end R Rod end Dimensions PA + Stroke B PB + Stroke A 4-EE (NPTF) 4-DD D across flats Stroke A Stroke B 4-NT Depth ND SN + Stroke A + Stroke B LF + Stroke A + Stroke B ZB + Stroke A + Stroke B Bore size (in)
phase J B C D A A COM COM COM B 12 VDC GND F.G.
Hs Auto switch 12 D-B5/B6 15 22.5 A B 33 410 Auto Switch Mounting CHA Series Auto Switch Proper Mounting Positions (mm) D-G5/K59 D-G5W/K59W D-G59F/G5BA D-G5NT D-M9/M9V D-M9W/M9WV D-M9A/M9AV D-F5/J59 D-F5W/J59W D-F59F/F5BA D-F5NT D-G39/K39D-A9/A9V D-A5/A6 D-A59W D-B5/B64 D-B59W D-A3/A44 Bore size (mm) CHQ A B A B A B A B A B A B A B A B A B A B A B CHK 40 20.5 21.5 17 18 22 23 12.5 13.5 10.5
phase J B C D A t A COM COM COM B 12 VDC GND F.G.
CG1N20-PS CG1N25-PS CG1N32-PS CG1N40-PS CG1N50-PS CG1N63-PS CG1N80-PS CG1N100-PS Contents C85 Rod cover Tube cover Piston Piston rod Bushing Bumper A Bumper B Snap ring Wear ring Rod end nut Piston gasket Cushion ring A Cushion ring B Seal retainer Cushion valve Valve retainer Lock nut Cushion seal A Cushion seal B Cushion ring gasket A Cushion ring gasket B Head cover Cylinder tube Rod seal
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 5, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 10, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 15, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 20, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: Without
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 mm, Stroke: 15 mm, Rod End Thread: With Thread, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m [Or None in the Case of No Switch], Number: 2 pcs. [Or None in the Case of No Switch], Option: XC22 (Fluoro Rubber Seals)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 mm, Stroke: 10 mm, Rod End Thread: With Thread, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m [Or None in the Case of No Switch], Number: 2 pcs. [Or None in the Case of No Switch], Option: XC22 (Fluoro Rubber Seals)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 mm, Stroke: 20 mm, Rod End Thread: With Thread, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m [Or None in the Case of No Switch], Number: 2 pcs. [Or None in the Case of No Switch], Option: XC22 (Fluoro Rubber Seals)
Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 mm, Stroke: 5 mm, Rod End Thread: With Thread, Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m [Or None in the Case of No Switch], Number: 2 pcs. [Or None in the Case of No Switch], Option: XC22 (Fluoro Rubber Seals)
B port D B C G1 U G2 U If B port of Body (B) is machined, the port is plugged with Rc 1/8.
B B B B B B RE A B 0 (0) 0 (0) 0 (2.5) 2 (6) 4 (7.5) 0 (0.5) 0 (0.5) 0 (3) 2.5 (6.5) 4.5 (8) 3.5 (6.5) 3.5 (6.5) 5.5 (9) 8.5 (12.5) 10.5 (14) 0 (2) 0 (2) 1 (4.5) 4 (8) 6 (9.5) 1 (4) 1 (4) 3 (6.5) 6 (10) 8 (11.5) 8.5 (11.5) 8.5 (11.5) 10.5 (14) 13.5 (17.5) 15.5 (19) 0.5 (3.5) 0.5 (3.5) 2.5 (6) 5.5 (9.5) 7.5 (11) 1 (0) 1 (0) 5.5 (1.5) 8.5 (4) 10.5 (6.5) 1.5 (0) 1.5 (0) 6 (2) 9 (4.5) 11 (7)