Size, Body, Valve Type: 30D (Size: 3; Body Mat'l: Aluminum; Port Size: 3/8; Orifice Dia: 5, N.C.), Voltage and Electrical Entry: J (110VAC); DIN Terminal w/Surge Voltage Suppressor), Other Voltages and Electrical Options: None, Other Options: A (G Thread)

Size, Body, Valve Type: 30D (Size: 3; Body Mat'l: Aluminum; Port Size: 3/8; Orifice Dia: 5, N.C.), Voltage and Electrical Entry: H (100VAC; DIN Terminal w/Surge Voltage Suppressor), Other Voltages and Electrical Options: None, Other Options: None, Bracket Interchangeable with Old Type: XB

This is a legacy product, and replaced byCJP2D10-30D

Symbol fl:] w 8$ Flow Characteristics NAN200 900 o Specifications 35 70 125 3s0 200 r7s0 An Flow (SCFMI Mar opetating pressu|e-145PSl(t0 2kg lcIrf) Nois reduction-30d B or more Operating tenperature range-40 1 40"F (5 ' 60 "C) Noise Level Model Model Port size (NPT) Eftectlve oririce mm2 (Cv) Wbight rbs.

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø10 mm, Stroke: 30 mm, Rod End Thread: With Thread, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, 0.5M, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: B (Basic), Bore Size: Ø16 mm, Stroke: 30 mm, Rod End Thread: With Thread, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, 0.5M, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in), Mounting: L (Foot), Bore Size: Ø10 mm, Stroke: 30 mm, Rod End Thread: With Thread, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, 0.5M, Lead Wire or Prewired Connector: L (3m)

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: A90,

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: A90,

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: A90,

Magnet: D (Built-in Magnet), Bore Size: 6 mm, Port Thread: Bore 6~25:M5, Bore 32: Rc 1/8, Stroke: 30 mm, Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5M, Lead Wire or Prewired Connector: L (3m)

Magnet: D (Built-in Magnet), VAC Side Tube/Rod End Shape: R (Rod Piping/Pad Direct Mounting), Bore Size: 16mm, Port Thread: M5x0.8 (Bore 10, 16, 20, 25), Rc1/8 (Bore 32), Stroke: 30mm, Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m, Lead Wire or Prewired Connector: L (3m)

Magnet: Built-in, Mounting: Flange, Bore Size: Ø10 mm, Stroke: 30 mm, Rod End Thread: With Thread, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Option: -

Magnet: Built-in, Mounting: Flange, Bore Size: Ø16 mm, Stroke: 30 mm, Rod End Thread: With Thread, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Option: -

Magnet: Built-in, Mounting: Foot, Bore Size: Ø16 mm, Stroke: 30 mm, Rod End Thread: With Thread, Auto Switch: A90--Reed, DC Volt >5<24, AC Volt <100, LED, 2 Wire, 0.5M, Lead Wire or Prewired Connector: 3m, Number: -, Option: -

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: A90,

Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: A90,

Cylinder (Tube) Inner Diameter(φ): 10, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Others, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Rubber cushion, Operating Pressure(MPa): 0.06 to 0.7, Specification: Built-in magnet, Auto Switches: A90,

Magnet: D (Built-in), Mounting: B (Through Hole, Both Ends Tapped), Bore Size: 16mm, Stroke: 30mm, Option: Standard (Rod End Female Thread), Auto Switch: A90--Reed, AC Volt, Horizontal, 0.5m, Lead Wire or Prewired Connector: L (3m)