25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 C85 -XC3 Special port location 63 1200 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600 -XC4 With heavy duty scraper C95 80 1400 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 Heat resistant cylinder (110 C) -XC5 100 1500 25, 50, 75, 100, 125, 150, 175, 200, 250,
25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 1400 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 100 1500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 Intermediate strokes are available.
25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 63 1200 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600 80 1400 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 100 1500 25, 50, 80, 100, 125, 160, 200, 250, 320, 400, 500, 600, 700, 800 Intermediate strokes are available.
output PNP open collector 1 output NPN open collector 1 output + Analog voltage output NPN open collector 1 output + Analog current output Symbol A B C D ARM ARP Accessory (Pressure gauge) Pressure Switch Specifications Nil None IR1000 series: G33--01 IR2000 series: G43--01 IR-A Set pressure range (MPa) 0.1 to 1 G Resolution of setting and display (MPa) 0.001 IR IR 12 to 24 VDC10%, Ripple (p-p
P-80 (YG) This catalog is printed on recycled paper with concern for the global environment.
Refer to p.0-26 and 0-27 for Safety Instructions and common precautions on the products mentioned in this catalog, and refer to p.2.0-7 and 2.0-8 for more detailed precautions of every series. Caution qMinimize the load shown below to protect the ball bearing. A flexible polyurethane tube is recommended. Kl Ml Hl Dl MS Tl 2.1-32 Series KS/KX Male connector: KSH (Standard) Tube O.D.
Refrigerated Air dryer Series IDU/IDF In compliance with the Montreal Protocol Regulations, P/A uses refrigerants R134a and R407C in its refrigerated air dryers to prevent any damage to the earth's ozone layer.
Please consult P/A for more information. Mounting bracket Auto switch capable. The cylinder should be operated within its allowable kinetic energy. (Refer to page 3.)
IO-Link 1.0 IO-Link -85No.PS-OMV0008CN-E ISE70G ISE75G ISE76G ISE77G ISE78G 01.000 MPa 02.000 MPa 05.00 MPa 010.00 MPa 016.00 MPa / -0.1051.050 MPa -0.1052.100 -0.255.25 -0.5010.50 MPa -0.8016.80 MPa MPa MPa / 0.001 MPa 0.01 MPa 3.0MPa 5.0 MPa 12.5 MPa 30 MPa 48 MPa DC12~24 V1010% IO-Link DC1830 V (p-p)10 35 mA 2% F.S.1 digit(253 ) 0.5F.S. (25 ) 3F.S. 5F.S.
Note 3)o0.085450/20BeltLinear guide5 to 4090 or less (No condensation)400 W/;60AC servo motor (100/200 VAC)Motor type S2, S3, S4: Incremental 17-bit encoder (Resolution: 131072 p/rev) Motor type S6, S7, S8: Absolute 18-bit encoder (Resolution: 262144 p/rev)72?2?1275Non-magnetizing lock1107.924 VDC 0 10%
Note 3)o0.085450/20BeltLinear guide5 to 4090 or less (No condensation)400 W/;60AC servo motor (100/200 VAC)Motor type S2, S3, S4: Incremental 17-bit encoder (Resolution: 131072 p/rev) Motor type S6, S7, S8: Absolute 18-bit encoder (Resolution: 262144 p/rev)72?2?1275Non-magnetizing lock1107.924 VDC 0 10%
Note 3)o0.085450/20BeltLinear guide5 to 4090 or less (No condensation)400 W/;60AC servo motor (100/200 VAC)Motor type S2, S3, S4: Incremental 17-bit encoder (Resolution: 131072 p/rev) Motor type S6, S7, S8: Absolute 18-bit encoder (Resolution: 262144 p/rev)72?2?1275Non-magnetizing lock1107.924 VDC 0 10%
Note 3)o0.085450/20BeltLinear guide5 to 4090 or less (No condensation)400 W/;60AC servo motor (100/200 VAC)Motor type S2, S3, S4: Incremental 17-bit encoder (Resolution: 131072 p/rev) Motor type S6, S7, S8: Absolute 18-bit encoder (Resolution: 262144 p/rev)72?2?1275Non-magnetizing lock1107.924 VDC 0 10%
Note 3)o0.085450/20BeltLinear guide5 to 4090 or less (No condensation)400 W/;60AC servo motor (100/200 VAC)Motor type S2, S3, S4: Incremental 17-bit encoder (Resolution: 131072 p/rev) Motor type S6, S7, S8: Absolute 18-bit encoder (Resolution: 262144 p/rev)72?2?1275Non-magnetizing lock1107.924 VDC 0 10%
Note 3)o0.085450/20BeltLinear guide5 to 4090 or less (No condensation)200 W/;60AC servo motor (100/200 VAC)Motor type S2, S3, S4: Incremental 17-bit encoder (Resolution: 131072 p/rev) Motor type S6, S7, S8: Absolute 18-bit encoder (Resolution: 262144 p/rev)41?2?725Non-magnetizing lock547.924 VDC 0 10%
Note 3)o0.085450/20BeltLinear guide5 to 4090 or less (No condensation)400 W/;60AC servo motor (100/200 VAC)Motor type S2, S3, S4: Incremental 17-bit encoder (Resolution: 131072 p/rev) Motor type S6, S7, S8: Absolute 18-bit encoder (Resolution: 262144 p/rev)72?2?1275Non-magnetizing lock1107.924 VDC 0 10%
Note 3)o0.085450/20BeltLinear guide5 to 4090 or less (No condensation)400 W/;60AC servo motor (100/200 VAC)Motor type S2, S3, S4: Incremental 17-bit encoder (Resolution: 131072 p/rev) Motor type S6, S7, S8: Absolute 18-bit encoder (Resolution: 262144 p/rev)72?2?1275Non-magnetizing lock1107.924 VDC 0 10%
Note 3)o0.085450/20BeltLinear guide5 to 4090 or less (No condensation)200 W/;60AC servo motor (100/200 VAC)Motor type S2, S3, S4: Incremental 17-bit encoder (Resolution: 131072 p/rev) Motor type S6, S7, S8: Absolute 18-bit encoder (Resolution: 262144 p/rev)41?2?725Non-magnetizing lock547.924 VDC 0 10%
Crean class Amount of Type Speed recommended vacuum (mm/s) ISO 14644-1 Fed.Std.209D aspiration 6 1000 10 5 100 20 4 10 30 6 1000 50 5 100 60 4 10 70 6 1000 20 5 100 30 4 10 50 6 1000 30 5 100 70 4 10 90 600 11-LEJS40 1200 600 *Please aspirate it from the port on both sides when aspirating 50/min(ANR). Please select "D" about the type. 11-LEJS63 1200 * Based on SMC test condition.
Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Attachment Specifications P. 14-2-24 IR Accessory P. 14-2-29 VEX Made to Order Specifications P. 14-2-31 AMR ITV IC VBA VE VY1 G PPA AL Soft Start-up Valve: AV2000/3000/4000/5000 P. 14-3-1 Lube Unit: AU P. 14-3-11 Large Flow Air Filter: AF800/900 P. 14-3-13 14-2-1 2 F.R.L.