Auto Switch Proper Mounting Position (Detection at Stroke End) Solid state auto switch D-M9 Reed auto switch D-A93 C B A Lead wire, in-line entry Values in the table below are used as a reference when mounting the auto switches for stroke end detection. For actually setting the auto switches, adjust them after confirming their operation.
Lead wire length (m) Load voltage Auto switch model Electrical entry direction Wiring (Output) Special function Electrical entry Indicator light Style 0.5 (Nil) 3 (L) Applicable load AC DC 12V Horizontal 100V 24V Reed switch 2-wire Relay, PLC Grommet Yes A93 12V 3-wire (NPN) M9N 24V Solid state switch Relay, PLC Grommet Yes 12V 2-wire M9B Lead wire symbol 0.5mNil (Example) A93
Note 3) ( ) in column W is the dimensions of D-A93.
Applicable models D-A73, A73H, A73C, C73, C73C, E73A, Z73, R73 D-97, 93A, A93, A93V D-A33, A34, A33A, A34A, A44, A44A D-A53, A54, B53, B54 2) However, when using a 2 color indication auto switch (DA79W, A59W, B59W), be aware that the switch will constantly remain ON if the connections are reversed.
Model RZQ32 RZQ40,50 RZQ63 Applicable floating joint JB40-8-125 Graph 1 JB63-10-150 200 JB80-16-200 63 100 Guide Shock absorber 50 Load weight (kg) 50 40 40 32 30 Floating joint 3 position cylinder 20 10 Maintenance Caution 5 150 100 200 300 1.
A90 A54 A64 A33C A34C A44C A59W B54 B64 A33 A34 A44 B59W 100 V Grommet IC circuit 100 V or less Yes No Relay, PLC 100 V, 200 V 2-wire PLC 12 V No 200 V or less 24V Terminal conduit Relay, PLC 100 V, 200 V DIN terminal Grommet Diagnostic indication (2-color indicator) 1 Water resistant type auto switches can be mounted on the above models, but in such case SMC cannot guarantee water
CJ216 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 16 Air cushion is not available for 21-/22-.
CJ216 15, 30, 45, 60, 75, 100, 125, 150, 175, 200 16 Air cushion is not available for 21-/22-.
Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: TN (NPT), Stroke: 800mm, Option: K (Heat Resistant Tarpaulin Rod Boot & Cushion at Both Ends), Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch
Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: TN (NPT), Stroke: 600mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: D (Built-in), Mounting: T (Center Trunnion), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: TN (NPT), Stroke: 400mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs.
Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Magnet: Built-in, Mounting: Center Trunnion, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: NPT, Stroke: 400mm, Option: Cushion at Both Ends, Cylinder Switch Type: No Switch, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 2 pcs.
Magnet: Built-in, Mounting: Center Trunnion, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 140mm, Thread: NPT, Stroke: 400mm, Option: Cushion at Both Ends, Cylinder Switch Type: A33--Reed, DC Volt >5 <24, LED, Terminal, None, Lead Wire or Pre-wired Connector: 0.5m Lead Wire (Or None in the Case of No Switch), Number: 1 pc.
Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 600, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 800, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure