SMC Corporation of America
Elite Part Number Search
Search Results "CDM2F20TNP-375-M9PSAPC-C"

Circuit for DC Circuit for AC Light A () A (+) SOL SOL C(+) Light () C ZNR Locking style(Slotted) VQZ100 Due to the use of non-polar light, the VQZ series has no polarity. Refer to p.1.12-26 for the latching style. Turn the manual override clockwise by 180 to set the E mark to "1" and press it in the direction indicated by arrow, then it will be locked in the ON state.

Turn the manual override counterclockwise by 180 to set the E mark to "0", then it will be reset. 200V AC 220V AC Red Red 200V AC 220V AC Indicator light With light and surge voltage suppressor Circuit for DC Circuit for AC Light A () A (+) SOL SOL C (+) C ZNR Light () Due to the use of non-polar light, the VQZ series has no polarity.

A B C D E F A B C D E F G H Pressure port Pressure port Right Left Left Right Left Right Right Left Left Right Right Left Left Right Operating direction Operating direction There are 9 possible reciprocating piping methods. There are 16 possible reciprocating piping methods.

(1) 5 to 55 Ambient temperature (C) 5 to 50 5 to 55 5 to 50 VC Outlet air atmospheric pressure dew point (C) 20 VDW Inlet air flow rate l/min (ANR) (2) 625 62 125 250 375 VQ Outlet air flow rate l/min (ANR) 50 100 200 300 500 VX2 Purge air flow rate l/min (ANR) (3) 12 25 50 75 125 VX Inlet air pressure (MPa) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080

Leakage voltage Particularly when using a resistor in parallel with a switching element and using a C-R element (surge voltage suppressor) to protect the switching element, take note that leakage current will flow through the resistor and C-R element, etc., creating a danger that the valve may not shut OFF.

(mm) 1.2 2.5 4 5 6.5 8 10 2 3.18 4.23 6.35 8.46 Black (B) White (W) Red (R) Blue (BU) Burst pressure (MPa) Yellow (Y) Burst pressure Green (G) Clear (C) Orange (YR) Solid blue (BU1) Max. operating pressure Clear blue (BU2) Medium blue (BU3) Brown (BR1) Solid green (G1) Operating temperature (C) Clear green (G2) Neon green (G3) Precautions Dark green (G4) Gray (GR1) Be sure to read before

to 50 5 to 55 5 to 50 Outlet air atmospheric pressure dew point C Standard performance 20 Inlet air flow rate l/min (ANR) Note 2) 625 62 125 250 375 Outlet air flow rate l/min (ANR) 50 100 200 300 500 Purge air flow rate l/min (ANR) Note 3) 12 25 50 75 125 Inlet air pressure MPa 0.7 Inlet air temperature C 25 25 25 1l/min (ANR) {inlet air pressure at 0.7MPa} Inlet air saturation temperature

JIS Standard Hydraulic Cylinder Double Acting/Single Rod 32, 40, 50, 63, 80, 100 CH2E/CH2F/CH2G/CH2H Series 3.5 MPa 7 MPa 14 MPa How to Order Rod size series Series type Cylinder stroke (mm) B C B-series rod size C-series rod size Tubing material Aluminum alloy Stainless steel Steel Stainless steel Symbol E F G H Nominal pressure 3.5 MPa 7 MPa 14 MPa 14 MPa Refer to the standard stroke table

1) 5 to 55 (23 to 131) Ambient temperature C (F) 5 to 50 (23 to 122) 5 to 55 (23 to 131) 5 to 50 (23 to 122) Outlet air atmospheric pressure dew point C (F) Standard performance 20 (-4) Inlet air flow rate l/min (ANR) (SCFM) Note 2) 625 (22.0) 62 (2.19) 125 (4.41) 250 (8.82) 375 (13.24) Outlet air flow rate l/min (ANR) (SCFM) 50 (1.8) 100 (3.5) 200 (7.1) 300 (10.6) 500 (1.77) Purge air flow

to 50 5 to 55 5 to 50 Outlet air atmospheric pressure dew point C Standard performance 20 Inlet air flow rate l/min (ANR) Note 2) 625 62 125 250 375 Outlet air flow rate l/min (ANR) 50 100 200 300 500 Purge air flow rate l/min (ANR) Note 3) 12 25 50 75 125 Inlet air pressure MPa 0.7 Inlet air temperature C 25 25 25 1l/min (ANR) {inlet air pressure at 0.7MPa} Inlet air saturation temperature

Where the ambient humidity exceeds the operating humidity range. c. Areas where abrupt temperature changes may cause condensation. d. Areas where corrosive gas, flammable gas or other volatile flammable substances are stored. e.

A-A A B B A Auto switch mounting bracket A-A B-B Dust seal band type Seal band holder roller specification C No.

Check the product for the following points before operation. a) Damage to power supply line and signal line. b) Looseness of the connector to each power line and signal line. c) Looseness of the actuator /cylinder and controller /driver mounting. d) Abnormal operation. e) Emergency stop of the total system. 3.

LOCK Applicable cable Cord O.D.: 3.5 to 7 (Reference) 0.5mm2 2-core and 3-core wires equivalent to JIS C 3306.

Series ID/IDW/IDA Heatless Air Dryers High Capacity Heatless Air Dryer Series IDA 73 86 114 170 205 295 409 591 818 1136 1909 2273 2955 4091 lbs Kg Weight 160 190 250 375 450 650 900 1300 1800 2500 4200 5000 6500 9000 A B C inch mm inch mm inch mm 610 610 711 787 813 838 1067 1168 1245 1524 1575 1575 1219 1575 24 24 28 31 32 33 42 46 49 60 62 62 48 62 711 864 813 940 914 1041 1143 1448 1524

Membrane Air Dryers 361 405 428 468 548 618 83 187 53 113 212 54 1/4 73 140 40 Port size L B A Port size L A B C 70 91 3/8 1/2 3/8 IN Port size: 1/4 OUT Port size: 1/4 IDG30, 30L IDG50, 50L IDG60 IDG75, 100 IDG60L, 60S IDG75L, 75S IDG100L, 100S Model Model (67) (46) (26) IDG3, 5 IDG10 IDG20 Width across flats 17 Width across flats 14 Width across flats 14 Purge air outlet for dehumidification

Piston Material: Aluminum, Added Function: N/A, Rod Motion: Double Acting Single Rod, Operating Pressure Range(MPa): 0.15~11, Tube Material: Stainless Steel, Piston Speed(mm/sec): 8~300, Piston Packing Material: NBR, Stroke(mm): 375, Cushioning Mechanism: Both Sides, Operating Temperature Range(°C): -10~80, Support Type: Retainer Pin/Stopper Set, Standard: JIS Specifications, Nominal Pressure

Series CM2 stainless steel cylinders are compact, lightweight and offer high performance. Improved piston seal and rod seal greatly improve the units life. Rubber bumpers are standard. The CM2 series offers a variety of mounting options and is auto switch capable. Centralized piping: double acting single rod, Bore sizes: 20, 25, 32, and 40 *, Strokes from 25mm through 500mm, Mounts: basic

Change ground water to tap water.) b) Consult a water treatment consultant about how to treat the water. c) Change the cooling method from transient type to circulating type, and use applicable facility water.

Plug lead, lead wire C kit, Individual connector, 7.5 pitch w/barb fittings, 8.5 pitch w/one-touch fittings, Up to 20 stations available as standard, Plug Lead Base Mount Bar Manifold, 3 PORT SOLENOID VALVE, G10, 375 lb