SMC Corporation of America
Elite Part Number Search
Search Results "CDNA2D100-350-D-M9PW"

Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Guided, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~60, Cushion: Air Cushion, Port thread type: Rc, Auto Switches: M9PW, Lead Wire Length(m): 3, The number of the switches

Cylinder (Tube) Inner Diameter(φ): 160, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: NPT, Auto Switches

Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.08 to 1.0, Specification

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 350, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

D-side w How to order applicable valves VQC 4 0 5 E B 0 Y 1 Series VQC4000 F E D A C B Stations are numbered in ascending order from the D-side.

D-side How to order applicable valves VQC 4 0 5 E B 0 Y 1 Series VQC4000 F E D A C B Stations are numbered in ascending order from the D-side.

1 Air flow capacity/Series IDU Model IDU75C IDU55C IDU37C1 IDU22C1 IDU15C IDU11C IDU8D IDU6D IDU4D IDU3D 10500 7650 5200 3150 2050 1300 850 640 430 300 50Hz Air flow capacity (l/min (ANR)) 12400 9000 6100 3700 2400 1500 1000 750 500 350 60Hz Data D-2 Air flow capacity/Series IDF Model IDF8D IDF6D IDF4D IDF3D IDF1D IDF2D IDF11C IDF15C IDF22C1 IDF37C1 IDF55C IDF75C IDF120D IDF150D IDF190D IDF240D

A: Acceleration time B: Constant velocity time C: Deceleration time D: Resting time (0.4sec.)

8 6 D-F9, D-F9W 5 4 D-Z7, Z80 9 9 11 A B D-Y59, Y7P D-Y7W 6 6 6 Switches cannot be mounted in some cases.

8 6 D-F9, D-F9W 5 4 D-Z7, Z80 9 9 11 A B D-Y59, Y7P D-Y7W 6 6 6 Switches cannot be mounted in some cases.

I' SU tl}El absorber : Sign : Red Green: Red: D-A56 .,,'""pan" \ . position D-F59 D-F5PW D-F59F Solid State Type Internal Circuit D-J59W D-F5P D-F5LF ~~ e Black D-F58A D-J59 D-F5NT AIIID SWitches Series C95 Suppon b racketexceptcenter tll.llYioo Center trunnion , Minimum Allowable Stroke When Mounting Auto Switches .. .

10 12 to 20 2.0 1.0 350 14 to 20 1.0 0.5 150 4 6 Slide table type LEPS Series 7 to 10 0.75 0.25 300 8 25 50 Page 383 25 to 50 2.0 1.5 200 5 24 to 40 2.0 1.5 200 10 12.5 to 25 1.5 1.0 350 10 12 to 20 1.5 1.0 350 370 LEPY/LEPS Series Mounting Variations Mounting from various directions Side mounting (Body mounting through-hole) Side mounting (Body tapped) LEF LEJ LEL LEM LEY LES LEPY LEPS

Size Order no. 25 LE-D-6-2 14 32 LE-D-6-3 40 LE-D-6-4 -12- 3. Product Outline 3.1 System construction Refer to the Driver operation manual for system construction. 4.Elictric actuators / Common precautions 4.1 Wiring/Cables Warning 1. Adjustment, installation, inspection, or wiring changes should be conducted after the power supply to this product has been turned off.

-S-200 350 207 330 6 2 300 11-LEFG32-S-250 400 257 380 11-LEFG32-S-300 450 307 430 11-LEFG32-S-350 500 357 480 8 3 450 11-LEFG32-S-400 550 407 530 11-LEFG32-S-450 600 457 580 Model L A B n D E 11-LEFG32-S-500 650 507 630 10 4 600 11-LEFG32-S-550 700 557 680 11-LEFG32-S-600 750 607 730 11-LEFG32-S-650 800 657 780 12 5 750 11-LEFG32-S-700 850 707 830 11-LEFG32-S-750 900 757 880 11-LEFG32-S-

side D side 3 m D-sub connector cable AXT100-DS25-030 Cylinder port fitting C8: 8 One-touch fittings Manifold base (8 stations) 10-SS5Q23-08FD2-D F kit (D-sub connector kit) 10-SS5Q23-08FD2-D 1 set (F kit 8-station manifold base) 10-SQ2131-51-C8 3 sets (2 position single) 10-SQ2231D-51-C8 3 sets (2 position double) 10-SQ2331-51-C8 1 set (3 position closed center) SSQ2000-10A-3 1

Bolts Size Belt Belt tension Part number (N) LEF16 LE-D-6-1 9.8 pull LEF25 LE-D-6-2 19.6 LEF32 LE-D-6-3 49.0 LEF40 LE-D-6-4 98.1 Bolts Size Tightening torque 6.Motor cover is installed. (Only "With motor cover") (Nm) M2.5 0.3610% M3 0.6310% M4 1.510% M5 310% The fingernail of "Grommet" is inserted in the hole of "Pulley box". Grommet 43 - 7.

Meter-out M5 type U10/32 port AS3200-02-D Meter-out M5 type U10/32 port AS2210-01-D AS3210-02-D Component Parts No.