(N.O. type/N.C. type can be changed.) 3 Do not connect wiring. 1 14 25 13 D-sub 25-pin female (socket) type 8 HRL Series Dual Channel Refrigerated Thermo-chiller for Lasers Communication Functions Serial Communication The following operations can be performed by the serial communication RS-232C/RS-485.
equipped as standard.) sPage 177 sPage 180 With fluid fill port 156 A Thermo-chiller Inverter Type HRSH Series Circulating Fluid Temperature Controller Circuit diagram HRSHl-W-l (Water-cooled refrigeration) HRSHl-A-l (Air-cooled refrigeration) HRS Ventilation DC inverter fan HRS 090 Water regulating valve Air release valve for facility water discharge HRS 100/150 WPR Facility water outlet D
Two mounting styles Table traveling accuracy C D Bottom mount Top mount Model Traveling accuracy C side against A side D side against B side LG1H 0.1 or less 0.1 or less A B Variations Mounting orientation Lead screw type Motor type Guide type Motor/Screw connection Series Standard motor [Tamagawa Seiki Co., Ltd.]
E F C (35.4[900]) J M N P L K H 4x0..5 (0.4[9~11mm] [4x13] [IDFB22E-11*(L=2800)] Unitinch [mm] A B C D E F G H J K L M N P 30.5 23.6 IDFB22E 1 [775] [600] 3.3 11.4 24.5 5.3 15.9 27.5 3.7 1.8 1 0.5 12.4 13.4 [290] [623] [134] [405] [698] [93] [46] [25] [13] [314] [85] [340] 26.8 33.7 IDFB37E 1/2 [855] [680] R IDFB55E/75E Q A B H G E D F C (0.4 (39.4[1000]) J L K M N P 4x0..5 [4x13]
Series HRS100/150 CAT.NAS40-62B R410A as refrigerant Thermo-chiller Standard Type Series HRS100/150 Circulating Fluid Temperature Controller Triple controller Fan Air-cooled condenser fan control Cooling valve Heating valve Circuit diagram Ventilation Cooling valve control Fan Facility water outlet Temperature sensor (Heat exchanger inlet) Water-cooled condenser Dryer Air-cooled condenser D
-phase 200 VAC 3-phase 400 VAC [mm] [mm]
Inverter pump Triple inverter HRZD HRW 0.6 kW 1.8 kW Water-cooled refrigeration Air-cooled refrigeration HECR 377 [mm] 970 HEC 2.4 kW HEB Triple inverter HRSH090 HED *1 Under the conditions shown on page 128 HEA Cooling capacity 9.5 kW IDH 1080 0.1C Temperature stability (when a load is stable) Set temperature range 5C to 40C W 377 x H 1080 x D 970 mm Compact, Space-saving Low-noise design
Main sealing Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Main sealing D side sealing A side sealing A seal is formed when the tubing is inserted, with its insert bushing, and its compression against the internal nut.
Suite D Poway, CA 92064 TEL: (858) 679-190s FAX: (858) 679-1904 ARGENTINA SMC Argentina S.A. CHILE SMC Pneumatics (Chite) Ltda.
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 25, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 50, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 60, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 75, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 1000, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 1100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 1200, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 125, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 140, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No