Non-standard Motor/Horizontal Mount Specification Series LJ1H30 Dimensions/LJ1H303PD(X10) Scale: 10% 8H10 depth 10 4-M8 x 1.25 thread depth 10 120 4-M12 x 1.75 thread depth 15 20 80 12.5 16.5 Cable entry side Work piece mounting reference plane 8H10 depth 8 Body mounting reference plane 212 160 Z section detail 63.5 63 Stroke + 204 (table movement range) 194.5 Z section 31.5 110 3.3 69 113 105
. 18 Standard Motor/Horizontal Mount Specification Series LJ1H30 Dimensions/LJ1H303PD Scale: 10% 8H10 depth 10 4-M8 x 1.25 thread depth 10 120 4-M12 x 1.75 thread depth 15 20 80 12.5 16.5 Cable entry side Work piece mounting reference plane 8H10 depth 8 Body mounting reference plane 212 160 Z section detail 63.5 63 Stroke + 204 (table movement range) 31.5 194.5 Z section 110 3.3 69 113 105
4 5 6 7 Stations D-side 8 U-side C10 3(R) port 2-C12 3(R) port DIN rail clamp screw 0 76.5 1 10 (12) 60 49.5 30 25 13.5 C10 1(P) port 25 (7.5) 45 P = 16 2-C12 1(P) port 2n-C4, C6, C8 C4: 4 One-touch fitting C6: 6 One-touch fitting C8: 8 One-touch fitting (mm) Formulas: L1 = 16n + 57, L2 = 16n + 102 n: Stations (maximum 16 stations) n L L1 L2 L3 L4 1 73 118 137.5 148 2 89 134 150 160.5 3 105
Timing Circuits Sample Components 3-Way Air Pilot MV-140 Control VAlve N2-DP Normally Closed Timer KLC-105 In this circuit, the 3-way valve is actuated and air is sent to the control valve. The control valve shifts, sending air to the rear of the cylinder causing the cylinder to extend. Air also flows to the timer where it begins to time to the pre-setting.
Station n L1 L2 L3 Station 20 236.5 228.5 220.5 3 58 50 42 6 89.5 81.5 73.5 8 110.5 102.5 94.5 10 131.5 123.5 115.5 Station 2 47.5 39.5 31.5 4 68.5 60.5 52.5 5 79 71 63 7 100 92 84 9 121 113 105 11 142 134 126 12 152.5 144.5 136.5 13 163 155 147 14 173.5 165.5 157.5 15 184 176 168 16 194.5 186.5 178.5 17 205 197 189 18 215.5 207.5 199.5 19 226 218 210 4-4-16 3 Port Pilot Operated Solenoid
Timing Circuits Sample Components 3-Way Air Pilot MV-140 Control VAlve N2-DP Normally Closed Timer KLC-105 In this circuit, the 3-way valve is actuated and air is sent to the control valve. The control valve shifts, sending air to the rear of the cylinder causing the cylinder to extend. Air also flows to the timer where it begins to time to the pre-setting.
I.D. 427 TU0425-100-X3 TU0604-100-X3 TU0805-100-X3 TU1065-100-X3 TU1208-100-X3 4 6 8 10 12 2.5 4 5 6.5 8 285 Max. operating pressure 142 0 4 32 70 105 140 10Clean Series Operating temperature F Only available in 20m rolls.
port Rc1/8 Dimensions/With DIN rail Station L1 L2 L3 2 70 105 140 3 105 140 175 4 140 175 210 5 175 210 245 6 210 245 280 3.8-6 ISA Guide for Use/Design Data When designing a pneumatic circuit with an Air-Catch Sensor, please refer to the data below.
l/min 5 to 105 l/min 10 to 100 l/min 1 l/min 1 l/pulse 10 to 210 l/min 10 to 210 l/min 20 to 200 l/min 2 l/min 2 l/pulse 25 to 525 l/min 25 to 525 l/min 50 to 500 l/min 5 l/min 5 l/pulse IF Data Accumulated pulse flow rate exchange value (Pulse width: 50 ms) l/min, CFM x 102 l/min, CFM x 101 Display unit Note 1, 2) Real-time flow rate Accumulated flow l, ft3 x 101 0 to 50C 5% F.S. or less
Refer to page 105 for details. Note 2) Can be changed to side ported configuration. Note 3) An optional specification for special wiring is available to increase the maximum number of stations. Refer to page 103 for details. Note 4) Except valves.
[ ] for AC Other dimensions are the same as the grommet. 3 58 50 42 6 89.5 81.5 73.5 Station L1 L2 L3 8 110.5 102.5 94.5 10 131.5 123.5 115.5 20 236.5 228.5 220.5 2 47.5 39.5 31.5 4 68.5 60.5 52.5 5 79 71 63 7 100 92 84 9 121 113 105 11 142 134 126 12 152.5 144.5 136.5 13 163 155 147 14 173.5 165.5 157.5 15 184 176 168 16 194.5 186.5 178.5 17 205 197 189 18 215.5 207.5 199.5 19 226 218
SO-63 27 28 60 M' 8Xl .5 15 27 12'870 1 6 ~f 38 ~10 100 105 37 40 83 M26Xl .S 24.5 28 20-8-08< 3():gJ Y-08d 80 37 36 71 M22Xl .S 19 28 181. 010 28!lH 55 V-1Od 100 37 40 83 M26Xl .S 21 38 201re
0.55 31 or less Rubber seal 24 or less 3.2 VQ2200 2.0 0.15 0.15 0.60 20 or less 0.46 20 or less Metal seal 15 or less 2.6 Double VQ2201 2.2 0.30 0.28 0.80 26 or less 0.55 26 or less Rubber seal 20 or less 3.2 VQ2300 2.0 0.18 0.15 0.46 58 or less 0.46 38 or less Metal seal 29 or less 2.0 Closed center VQ2000 VQ2301 2.0 0.31 0.28 0.60 64 or less 0.49 44 or less Rubber seal 34 or less 2.2 105
with AMC810-14 installed) ( 105 with AMC810-14 installed) 118 (135) 159 (172.5) (105 with AMC810-14 installed) (= 105 with AMC810-14 installed) 159 (172.5) 158.7 158.7 3/4" 1(P), 5(R1), 3(R2) port 3/4" 1(P), 5(R1), 3(R2) port 2 x G1 (Electrical entry) 12 21 47.5 47.5 36 21 4.4 4.4 12 1/8" PE. port 29.5 29.5 29.5 29.5 1/8" PE. port 83 Formula: L1 = 41n + 76, L2 = 41n + 96 n: Stations (Maximum
ZSE20 ISE20 100 kPa 0 100 kPa 500 kPa 1 MPa Pressure range ZSE30 ISE30 ZSE30 ISE30 Switch ZSE40 ISE40 For vacuum pressure 101 kPa 0 ZSE30A 10 kPa 105 kPa ZSE10 ISE10 For compound pressure 100 kPa 100 kPa ISE70 ZSE30AF 105 kPa 105 kPa ZSE80 ISE80 For positive pressure 100 kPa 1 MPa ISE30A 105 kPa (0.105 MPa) 1.05 MPa PS Rated pressure range of switch Set pressure range of switch ISA3 ISA2
Ltd. 1-16-4 Shimbashi, Minato-ku, Tokyo 105-8659, JAPAN Tel: 03-3502-2740 Fax: 03-3508-2480 URL http://www.smcworld.com 2002 SMC Corporation All Rights Reserved Specifications are subject to change without prior notice and any obligation on the part of the manufacturer.
NDH10 125 140 160 I-12 I-14 I-16 0.1 0.3 25 32 +0.084 0 2033 27 46 54 100 M30 x 1.5 E1 0.1 0.3 28 36 +0.084 0 39 30 48 54 105 M30 x 1.5 NX 0.1 0.3 32 40 +0.100 0 Data 39 34 55 60 110 M36 x 1.5 L1 U1 RR1 Rod End Nut Material: Rolled steel 30 d Applicable bore size (mm) d H B C D Part no.
Conductor Insulator Outside diameter 1.4 mm Blue, Brown 0.7 mm White, Green, Light green, Purple, Gray, Yellow Sheath Material Heat resistant PVC Outside diameter 6.2 mm AC adapter IZF21-CG1 (with AC cord) 98.8 2144 +105 100 1820 50 46.8 AC adapter AC cord IZF21-CG2 (without AC cord) 2144 +105 100 32.1 98.8 46.8 Inlet IEC60320-C6 AC adapter *: The input (AC) side and output (DC) side of the
A 13 15 22 06 08 10 340 400 460 580 640 820 1120 1300 1600 1900 2320 2500 End bracket/IZS40-BE 35 22 4.5 30 44 2 x 5.4 18 105 33 L 33 Intermediate bracket/IZS40-BM 55 35 22 4.5 36 30 18 2 x 5.4 A 105 33 A A-A section 432 Ionizer IZS40/41/42 Series Dimensions Feedback sensor/IZS31-DF 2 x 3.4 Amplifier 2 x 3.4 Head 1500 3500 IZS IZS 9 16.6 13 SMC IZN 4.8 10.2 25 58 4.8 69 23 87.5 IZF 78 ZVB
It is calculated using the following formula. 1 x 105 Kv = Q (8) P 1000 Kv : Flow coefficient [m3/h] Q : Flow rate [m3/h] DP : Pressure difference [Pa] r : Density of fluid [kg/m3] (3) Formula of flow rate It is described by practical units. Also, the flow rate characteristics are shown in Graph (2).