SMC Corporation of America
Elite Part Number Search
Search Results "CLSB250-400-D"

Printed in Japan. 1st printing October, 2000 D-SMC.L.A. P-80 (D)

D-B5/B6, D-B59W, D-A3/A44 Band mounting Reed switch Tie rod mounting D-A5/A6, D-A59W, D-A3C/A44C D-G5/K59, D-G5NTL, D-G5W/K59W D-G5BAL, D-G59F, D-G39/K39 D-F5/J5, D-F5NTL, D-F5W/J59W D-F5BAL, D-F59F, D-G39C/K39C D-H7, D-H7W, D-H7F, D-H7BAL, D-H7C, D-G5NTL, D-G39A/K39A Band mounting Solid state switch Tie rod mounting 3.4-1 Series CB Prior to Use Precautions Be sure to read before handling

D (A) (B) (B) OUT OUT 305 Tank OUT port Rc1/2 ARM 216 216 180 4 x 13 4 x 13 50 50 ARP Drain valve 100 100 Drain port Rc1/4 IR-A 200 200 400 700 678 IR Booster regulator model A B C D VBA20A 481 394 Rc3/8 VBA40A 520 429.8 Rc1/2 VBA22A 444 394 Rc3/8 469 VBA42A 477 429.8 Rc1/2 493 IRV The length may be longer than the specification if the plugs mounted on the tank are not fit to the end.

50 100 150 200 250 300 350 400 Stroke MXY6 2 3 3 4 39 34 59 54 MXY8 5 5 34 59 2 2 3 4 39 64 54 44 MXY12 2 4 4 5 5 37 67 47 72 52 77 2 3 3 62 42 8-9-12 12 Air Slide Table Long Stroke Type Series MXY Proper Auto Switch Mounting Position (Detection at stroke end) Reed Switch D-A90(V), D-A93(V), D-A96(V) (mm) Lead wire entries outside A A Model Mounting Switch operating range A B A B

MY1CW16/20 MY1MW16/20 B A Reed Switch Solid State Switch D-A90(V), D-A93(V), D-A96(V) (mm) D-M9N(V), D-M9P(V), D-M9B(V) D-F9NW(V), D-F9PW(V), D-F9BW(V) 16 20 Mounting position Mounting position 16 20 A A B B Operating range Note) Operating range Note) Solid State Switch Reed Switch 24 Series MY1W Mounting of Auto Switch & Installation of Lead Wire Cover (50, 63) Caution Be sure to install

Pipe thread type Note 1) 400 V type is provided with an earth leakage breaker with handle (-B1) as standard.

Auto Switch Proper Mounting Position (mm) Auto switch model D-M9 D-M9W D-A9 Bore size A A B B 20 25 32 40 10.5 9.5 6.5 5.5 10.5 9.5 6.5 5.5 11.5 10.5 7.5 6.5 17.5 15.5 13.5 11.5 Note) The above-mentioned value is a guide for auto switch mounting positions for stroke end detection.

D type DIN connector with 9.4 mm pitch between terminals is not interchangeable. 3. DIN connector except D type has the N indication in the end of voltage symbol. In case of DIN connector without light, N is not indicated. Please refer to the name plate to distinguish. 4. Dimensions are completely the same as D type connector. 5.

Note 2) 400 V type is provided with an earth leakage breaker -B as standard.

d A IZN10E-01 02m06 6 3.5 IZN10E-01 02m07 1/4" 7 34.7 26 2 x M3 x 0.5 thread depth 10 11 291 *1 Dimension of the resin part in described in the Mounting Warning note 3 (page 24). 18.31 One-touch fitting (Elbow) IZN10E-mm 16 17 D B C Applicable tubing O.D. d 180 [mm] Model d B C D IZN10E-mm16 6 22 16 11.5 IZN10E-mm17 1/4" 24.5 18.5 12 Female threads for piping (Rc1/8) IZN10E-11mm 14 Rc1/

0 t r i w y e q o Replacement Parts (For valve) Description VQ7-8-FG-SVQ7-8-FG-DVQ7-8-FPG-DVQ7-8-FG-S-R VQ7-8-FG-D-R VQ7-8--D-R VQ7-8--DNumber q w e r t y u i o !

I' SU tl}El absorber : Sign : Red Green: Red: D-A56 .,,'""pan" \ . position D-F59 D-F5PW D-F59F Solid State Type Internal Circuit D-J59W D-F5P D-F5LF ~~ e Black D-F58A D-J59 D-F5NT AIIID SWitches Series C95 Suppon b racketexceptcenter tll.llYioo Center trunnion , Minimum Allowable Stroke When Mounting Auto Switches .. .

B A (mm) Applicable auto switch D-A72 D-A7H/A80H D-A73C/A80C D-F7/J79 D-F7V/J79C D-F7W/J79W D-F7WV D-F7BA/F7BAV D-F79F Other than the models listed in How to Order, the following auto switches are applicable. For detailed specifications, refer to page 1627.

C F G D E F G D T F G D F F G E S F G E L F G E T F G G S F G G L Fluid name Applicable element type, material Nominal filtration accuracy (m) Fiber element Polypropylene 10 Industrial water Fiber element Polypropylene 20 Water for cleaning Fiber element Polypropylene 20 Water Fiber element Cotton 10 Fragrances Micromesh element Stainless steel 316 10 Hot water Micromesh element Stainless

Insert D at the end of the manifold part number.

1.09 1.20 1.181.25 1.42 1.68 1.86 2.03 2.21 2.382.56 2.09 2.20 2.49 2.77 3.17 3.46 3.74 4.03 4.32 4.60 4.89 LEY 16 D LEY 25 D LEY 32 D [mm] 1) 30 50 100 150 200 250 300 30 50 100 150 200 250 300 350 400 30 50 100 150 200 250 300 350 400 450 500 (kg) 0.580.62 0.73 0.87 0.98 1.09 1.20 1.17 1.24 1.41 1.67 1.85 2.02 2.20 2.382.55 2.08 2.19 2.48 2.76 3.16 3.45 3.73 4.02 4.31 4.59 4.88 [kg] 0.12

385 Max. speed[mm/s] 400 200 400 200 400 200 Pushing speed [mm/s] *2 35 or less 30 or less Actuator specifications Max. acceleration/deceleration[mm/s2] 5000 Positioning repeatability [mm] 0.01 Lost motion [mm] *3 0.1 or less Lead [mm] (including pulley ratio) 12 6 20 10 16 8 Impact/Vibration resistance [m/s2] *4 50/20 Ball screw Ball screw(In-line) Actuation type Belt[1.25:1] Ball screw

rate: 50% Stroke 500 mm Series CM2 Pressure 0.5 MPa Load rate: 50% Stroke 300 mm Average speed (mm/s) Series 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation SY3140-01 Horizontal actuation 800 700 600 500 400 300 200 100 0 SY5140-02 800 700 600 500 400 300 200 100 0 SY7140-03 800 700 600 500 400 300 200 100 0 SY9140-04 Cylinder is in extending.

Recommended shim thickness) Arm length L: 6 in 0.04 0.02 0.06 500 Clamping force (lbf) 400 0.7 MPa 300 0.5 MPa 0.3 MPa 200 100 0 0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 Shim thickness (in) 186 Model Selection 2 Slim-line power clamp cylinder mounting 63 Arm length L: 200 mm 4000 Clamping force (N) 3000 CK1 CLK2 C(L)KQ MK2T/MK2/MK CKZ2N CKZT CLKZ1R CK/M(D)UKA 2000 1000 0 0 1 2 3 4 5 6 7 8 9 Shim