How to Order B 20 30 D C CQSY Without auto switch F9BW S B 20 30 D C CDQSY With auto switch Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Number of auto switches Built-in magnet 2 pcs. 1 pc. n pcs.
(VZ415) Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Component Parts Replacement Parts Description NBR Stainless steel Material Part no.
Note 2) D-Z73, D-Z76, D-Z80 D-F79, D-F7P, D-J79 D-F7NV, D-F7PV, D-F7BV D-J79C D-F79W, D-F7PW, D-J79W D-F7NWV, D-F7BWV Note 1) D-F9N, D-F9P, D-F9B Note 2) D-Y59A, D-Y7P, D-Y59B D-Y69A, D-Y7PV, D-Y69B Note 2) D-Y7NW, D-Y7PW, D-Y7BW D-Y7NWV, D-Y7PWV, D-Y7BWV D-F7BA D-F7NT D-F79F D-F7LF Note 1) Indicates auto switches for CY1R6 to 20.
Auto Switch Mounting Height [mm] Auto switch model D-F5m D-J59 D-F59F D-F5mW D-J59W D-F5BA D-F5NT D-Y59m D-Y7P D-Y7mW D-Y7BA D-Z7m D-Z80 D-M9m D-M9mW D-M9mA D-A9m D-A9mV D-M9mV D-M9mWV D-M9mAV D-A5m D-A6m D-A59W D-Y69m D-Y7PV D-Y7mWV D-P3DWA D-P4DW D-G39 D-K39 D-A3m D-A44 Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht Hs Ht 32 24.5 23 27.5 23 30.5 23 32.5 25 35 24.5 67 27.5 77
D-A9 (Reed switch) D-F9W D-M9 (Solid state switch) D-M9V, D-F9WV D-A9V (Reed switch) D-M9V D-F9WV (Solid state switch) C3 CXSJ15 to 32 Bore size (mm) C2 Symbol Auto switch model A1 32 0.3 7.1 6.2 3.1 25 0.3 7.1 6.2 0.4 20 0.3 7.1 6.2 1.2 15 0.3 7.1 6.2 2.2 C1 A1 C1 C2 C3 D-F9W, D-M9 D-A9V, D-F9WV D-M9V D-A9 (Reed switch) D-F9W (Solid state switch) D-M9 D-A9V (Reed switch) D-F9WV (Solid state
A A B C D E F A B C D A B C D A B C D A B C D Tubing O.D. PA 1 2 1 2 3 4 1 2 3 4 5 6 1 2 3 4 1 2 3 4 1 2 3 4 1/8" 1/8" PAX 1/8" 1/8" PB 1/4" 1/4" 1/4" 1/4" 3/8" 3/8" 3/8" 3/8" 1/2" 1/2" 1/2" 1/2" 3/4" 3/4" 3/4" 3/4" 1" 1" Note) For each body class, the second and later numbers or symbols indicate reducing.
Magnet: None, Mounting: L (Foot), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 250mm, Thread: TN (NPT), Stroke: 600mm
Magnet: None, Mounting: L (Foot), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 250mm, Thread: TN (NPT), Stroke: 150mm
Magnet: None, Mounting: L (Foot), Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 250mm, Thread: TN (NPT), Stroke: 150mm, Option: K (Heat Resistant Tarpaulin Rod Boot & Cushion at Both Ends)
Magnet: None, Mounting: Foot, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 250mm, Thread: NPT, Stroke: 600mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -
Magnet: None, Mounting: Foot, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 250mm, Thread: NPT, Stroke: 150mm, Option: -, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -
Magnet: None, Mounting: Foot, Tube: 125~160 Aluminum (with or w/o magnet);180~200 Steel (w/o magnet),Aluminum (w/magnet);250 Steel, Bore Size: 250mm, Thread: NPT, Stroke: 150mm, Option: Heat Resistant Tarpaulin Rod Boot & Cushion at Both Ends, Cylinder Switch Type: -, Lead Wire or Pre-wired Connector: -, Number: -, Lock Unit Built-in Magnet: -, Lock Unit Switch Type: -
mm 176 mm HECR012-W2 HRCR010-A2 Air-cooled Air-cooled Water-cooled 200 W, 400 W, 510 W 800 W, 1 kW 800 W, 1.2 kW Mountable in a 19-inch rack Space can be saved by mounting multiple pieces of equipment together in a single rack.
4.5 1 1 Note) There is no protrusion for sections of the table with no values entered. 6.5 6.5 6.5 6.5 0.5 0.5 3 3 1 1 4.5 4.5 4.5 4.5 1 1 6.5 6.5 6.5 6.5 0.5 0.5 3 3 1 1 Hysteresis MHF2-8D D-M9(V) D-M9W(V) MHK Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
2 output + Auto shift input Refer to the dimensions for the difference between brackets A and D.
Note 2) When symbols C or D are specified, an auto drain with a part number shown on page 18 is mounted.
D-A80 U B + First-stage stroke U B A Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com D-A7H D-A80H D-F7 D-J79 D-F7W D-J79W D-F79F D-Y7NTL D-F7BAL B + First-stage stroke U SMC U B A D-A73C D-A80C D-J79C B + First-stage stroke U U B A D-A79W D-F7WV D-F7V D-F7BAVL B
) 258-9200-www.stevenengineering.com D-sub connector 6 One-touch fitting Terminal no.
) 258-9200-www.stevenengineering.com 14 (2, 4 port) 112 93 12 Y 25 (14 port) PE port 5 3 37 25 22 14 1 25 25 9 1/8 12 port 3/8-2 port 3, 5 port 1/4, 3/8 1 port 14 port 1/8 1/4, 3/8-2 port 2, 4 port EVS7-6-FG-D-M0 EVS7-6-F G-D-M0 H J I 186 196 89 89 13 (4 port) 50 50 13 (2 port) 13 (4 port) 50 50 13 (2 port) B A B A 50 62 50 62 38 14 38 12 14 12 Manual override Manual override P R1 R2 P