Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 40 Inch, Adjuster: Adjuster Bolt, Auto Switch: J79L--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Horizontal, 3M, Number: -
Magnet: Built-in, Bore Size: 1 1/4 Inch, Magnetic Holding Force: Large Holding Force, Stroke: 4 Inch, Adjuster: Cap Type Shock Absorber (2 pcs.), Auto Switch: J79L--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Horizontal, 3M, Number: -
Magnet: Built-in, Bore Size: 1 Inch, Magnetic Holding Force: Small Holding Force, Stroke: 20 Inch, Adjuster: Shock Absorber (2 pcs.), Auto Switch: J79L--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Horizontal, 3M, Number: -
Magnet: Built-in Magnet, Rotation Angle: 180°, Auto Switch: J79L--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Horizontal, 3M, Number: -
Magnet: Built-in Magnet, Rotation Angle: 90°, Auto Switch: J79L--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Horizontal, 3M, Number: -
Size: 10mm, Rotation Angle: 170° to 190°, Auto Switch: J79L--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Horizontal, 3M, Number: -
Size: 10mm, Rotation Angle: 80° to 100°, Auto Switch: J79L--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Horizontal, 3M, Number: -
Size: 15mm, Rotation Angle: 80° to 100°, Auto Switch: J79L--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Horizontal, 3M, Number: -
Size: 15mm, Rotation Angle: 170° to 190°, Auto Switch: J79L--Solid State, Gen. Purpose, 2 Wire, Lead Wire, Horizontal, 3M, Number: -
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
With no external leakage, the CY series can be used in many diverse environments. Magnetically coupled cylinders have a wide range of applications, and save mounting space. Loads and moments are possible through the use of integrated guides. A variety of guides can be used to achieve the necessary accuracy or allowable moment needed for your application. CY is available in 9 bore sizes,
Main Body Peripheral Component: Main Body, Type: Sliders, Stroke(mm): 150, Max. Transportable Mass Range (Horizontal)(kg): 2.1 to 5.0, Max. Transportable Mass (Horizontal)(kg): 5, Max. Transportable Mass Range (Vertical)(kg): 2.1 to 5.0, Max. Transportable Mass (Vertical)(kg): 5, Drive Method: -, Guide: Included, Lead(mm): 8, Input Power Supply: DC 24V, Position Detection: Incremental, I/
Main Body Peripheral Component: Main Body, Type: Sliders, Stroke(mm): 150, Max. Transportable Mass Range (Horizontal)(kg): 2.1 to 5.0, Max. Transportable Mass (Horizontal)(kg): 5, Max. Transportable Mass Range (Vertical)(kg): 2.1 to 5.0, Max. Transportable Mass (Vertical)(kg): 2.5, Drive Method: [Slide Screws] Slide Screw + Belt, Guide: Included, Lead(mm): 16, Input Power Supply: DC 24V,
Bore Size: 32mm, Port Thread: Rc, Magnetic Holding Force: Large Holding Force, Stroke: 150mm, Adjuster: BS [Shock Absorbers (w/Plate A) Installed on A Side when Shipped]
Cylinder (Tube) Inner Diameter(φ): 25, Stroke(mm): 150, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Guided, Additional Function: High rigidity / high precision high class guide, Environment, Applications: Standard, Cushion: With shock absorber (1 pc.), Operating Pressure(MPa): 0.10 to 1.0, Specification: With magnet, Port thread
Size: 25, Motor Mounting Position: Basic Type, Motor Type: A [Servo Motor, (24 VDC)], Lead: LES8: 8mm; LES16: 10mm; LES25: 16mm, Stroke: 150mm, Motor Option: w/Lock, Body Option: Dustproof Specification, Mounting: -, Actuator Cable Type: -, Actuator Cable Length: -, Controller Type - LEC, JXC: -, I/O Cable Length for LEC: -, Controller Mounting: -, Communication Plug Connector or I/O Cable
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: H (Large Holding Force), Stroke: 150mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: None, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Bore Size: 25mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: L (Small Holding Force), Stroke: 150mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: None, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Bore Size: 15mm, Port Thread: Rc (or M Thread for 6 to 15 Bore), Magnetic Holding Force: L (Small Holding Force), Stroke: 150mm, Adjuster: B (Shock Absorbers (2 pcs)), Auto Switch: None, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)
Bore Size: 20mm, Port Thread Type: TN (NPT), Adjuster Position Set: Right Side, Stroke: 150mm, Adjuster: B (Both Sides Adjusters/Shock Absorbers), Auto Switch: No Switch, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: S (1 pc.)