Operating temperature range (C) 5 to 60 Standard Strokes Bore sizes (mm) Standard strokes (mm) Max. manufacturable stroke (mm) 16 100, 200, 300, 400, 500, 600, 700 800, 900, 1000, 1200, 1400, 1600 1800, 2000 3000 20, 25, 32, 40, 50, 63 Strokes can be manufactured in 1mm increments, up to the maximum stroke.
(Between lead wire and the case) 1000 m/s2 300 m/s2 Impact resistance 50 M or more at 500 M VDC (Between lead wire and case) Insulation resistance 1500 VAC for 1 minute 1) (Between lead wire and case) 1000 VAC for 1 minute (Between lead wire and case) Withstand voltage Except magnetic resistant 2-color indication type solid state switch (DP5DWL/P5DWSC).
: Built-in magnet, Port thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Mount Support: Basic type, Rod Boot: None, Custom-made Specifications: None, Locking Direction: Bidirectional
: Built-in magnet, Port thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Mount Support: U-Shaped Clevis Type, Rod Boot: None, Custom-made Specifications: None, Locking Direction: Bidirectional
Cylinder (Tube) Inner Diameter(φ): 80, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure
cushions on both sides, Operating Pressure(MPa): -, Specification: -, Support bracket: Head-end flange, Port thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Rod Boot: Without rod boot, Tube Material: Aluminum tube, Custom-made Specifications: None, Locking Direction: Bidirectional
thread type: Rc, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Rod End Bracket: None, Type of Mount Support: Rod-end flange type, Rod Boot: None, Custom-made Specifications: None, Customized specification (port positions): -, Type: Non-lube, Stroke adjustment symbol: -
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No
Cylinder (Tube) Inner Diameter(φ): 63, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Brake / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: [Included] Presence, Valves: No,
magnet, Auto Switches: A93, Lead Wire Length(m): 3, The number of the switches: 2, Type of Auto Switch Mounting: Standard, Type of Mount Support: Basic type, Rod Boot: Without rod boot, Custom-made Specifications: None
Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: NPT, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: Rc, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: No, Valves: Presence, Cushion: With cushions on both sides, Operating Pressure(MPa): 0.05 to 0.97, Port thread type: NPT, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 140, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Specification: Built-in magnet, Port thread type: NPT, Auto Switches: A93, Lead Wire Length(m): 5, The number of the switches
(Applicable for round bar, roller and chamfered type rod end configurations.) 1.0 1.0 -X Operating pressure P (MPa) Operating pressure P (MPa) RSQ20 RSQ40 RSQ12 20RSQ16 RSQ32 0.5 0.5 Data RSQ50 0 500 0 50 100 Lateral load F (N) Lateral load F (N) 10-8-5 6 Series RSQ Construction Single acting, Roller rod end Built-in shock absorber Lever rod end type (32, 40, 50 only) 12 16 !4 @1 @2 !
A retaining mechanism prevents the cushion needle from coming out, however, it may spring out during operation if it is rotated beyond the ranges shown above. 1 100 500 Maximum speed mm/s 3. Adjust the cushion needle to reduce excessive kinetic energy from the piston impact at the stroke end by absorbing enough kinetic energy during the cushion stroke.
Cylinder (Tube) Inner Diameter(φ): 50, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 500, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, End Locking: -, Valves: -, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches