Search Results "G36-P2-01-X30"

Pressure Gauge: G36 (ø37.5 Outside Diameter, Back Side Thread), Display Pressure: 2 (0.2MPa), Connection Thread: 01 (R 1/8), Option: X4 [Oil-free (Wetted Parts Degrease Washing)

Pressure Gauge: G36 (ø37.5 Outside Diameter, Back Side Thread), Display Pressure: 10 (1.0MPa), Connection Thread: 01 (R 1/8)

Pressure Gauge: G36 (ø37.5 Outside Diameter, Back Side Thread), Display Pressure: 2 (0.2MPa), Connection Thread: 01 (R 1/8)

Pressure Gauge: G36 (ø37.5 Outside Diameter, Back Side Thread), Display Pressure: 7 (0.7MPa), Connection Thread: 01 (R 1/8)

Pressure Gauge: G36 (ø37.5 Outside Diameter, Back Side Thread), Display Pressure: 4 (0.4MPa), Connection Thread: 01 (R 1/8)

Pressure Gauge: G36 (ø37.5 Outside Diameter, Back Side Thread), Display Pressure: 15 (1.5MPa), Connection Thread: 01 (R 1/8)

Pressure Gauge: G36 (ø37.5 Outside Diameter, Back Side Thread), Display Pressure: 10 (1.0MPa), Connection Thread: 01 (R 1/8), Option: X4 [Oil-free (Wetted Parts Degrease Washing)

(full span), GAUGE, AIRLINE EQUIPMENT, AR REGULATOR, 22, AR NO SIZE RATKIT/ACCESSORY, .17636 lb, ModelPressure range (1)Green zone setting rangeIndication unitConnection threadNote MPaMinimum setting range (MPa)Maximum setting range (MPa)G36-10-01-L0 to 1.00.050.5MPaR 1/8?

Supply pressure verification Leak test P2(n1) > P1(n2) P2(n2) P1(n1) 10.0 to 101.0kPa CH Increases the set value 1 2 3 4 PRESSURE For normally closed P2(n1) > P1(n2) P2(n2) P1(n1) 0.1 to 1000.0MPa Decreases the set value SET P3(n3) and P4(n4) are the same as P1(n1) and P2(n2).

2-Color Display Type High-Precision Digital Pressure Switch Series ZSE30/ISE30 How to Order Option 1 Without lead wire Nil Lead wire with connector (Lead wire length: 2m) L ISE30 01 25 M For positive pressure ZSE30 01 25 M For vacuum/Low pressure Option 2 Piping specification R 1/8 (with M5 female thread) NPT 1/8 (with M5 female thread) 01 T1 None Bracket Nil A Output specification NPN output

25 M For positive pressure ZSE30 01 25 M For vacuum/Low pressure Option 2 Piping specification R 1/8 (with M5 female thread) NPT 1/8 (with M5 female thread) 01 T1 None Bracket Nil A Output specification NPN output PNP output 1 to 5V output 4 to 20mA output 25 65 26 28 Panel mount B Unit specification Nil M With unit switching function Fixed SI unitI (International System of Units) Note)

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com L ISE30 01 25 M For positive pressure ZSE30 01 25 M For vacuum/low pressure Option 2 Piping specifications Nil None Bracket R 1/8 (With M5 female thread) 01 NPT 1/8 (With M5 female thread) A T1 Straight type 4 One-touch fitting 5/32" One-touch fiting

As a guide, adjust P2, so that it could be W + P2A = P0a.

As a guide, adjust P2, so that it could be W + P2A = P0a.

Note 3) Window comparator mode Since hysteresis is 3 digits, separate P1 and P2 by 7 digits or more. 1 digit is the minimum setting unit (refer to the table above).

Q=14.2Cv 10.2 P l/min G Formula based on effective area (Smm) Q=0.8S 10.2P l/min G Other : Flow rate (l/min) : Pressure differential (P1 P2) : Upstream pressure (MPa) : Downstream pressure (MPa) : Effective area (mm) : Cv factor : Fluid specific gravity (water = 1) Q P P1 P2 S Cv G 1. Materials FKM: Fluoro rubber Trade names: Viton, Dai-el, etc. 2.

Q=14.2Cv 10.2 P l/min G Formula based on effective area (Smm) Q=0.8S 10.2P l/min G Other : Flow rate (l/min) : Pressure differential (P1 P2) : Upstream pressure (MPa) : Downstream pressure (MPa) : Effective area (mm) : Cv factor : Fluid specific gravity (water = 1) Q P P1 P2 S Cv G 1. Materials FKM: Fluoro rubber Trade names: Viton, Dai-el, etc. 2.

R1 1 ZX1 06 R ZZX1 Supply port location 01 1 Stations Arrangement (First station from the right end of the valve side is station 1.)

How to Find the Flow Rate (at air temperature of 20C) Subsonic flow when P1 + 0.1013 < 1.89 (P2 + 0.1013) Q = 226S P(P2 + 0.1013) Sonic flow when P1 + 0.1013 1.89 (P2 + 0.1013) Q = 113S (P1 + 0.1013) Q: Air flow rate [l/min (ANR)] S: Effective area (mm) P: Differential pressure (P1-P2) [MPa] P1: Upstream pressure [MPa] P2: Downstream pressure [MPa] Correction for different air temperatures