Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 (3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz)), Option: J (w/Automatic Fluid Fill Function)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 (3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz)), Option: M (Applicable to Deionized Water Piping)
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 40 (3-phase 380 to 415 VAC, 50/60 Hz; 3-phase 460 to 480 VAC (60 Hz)), Option: JM (w/Automatic Fluid Fill Function + Applicable to Deionized Water Piping)
Cooling Capacity: 200 (20.5kW), Thread: N (NPT, w/Rc-NPT Conversion Fitting), Option: AKM (A + K + M)
Cooling Capacity: 200 (CH1: 19 kW; CH2: 1 kW), Pipe Thread: N [NPT (Rc-NPT Thread Adapter Set is Included)], Power Supply: 40 [3-phase 380 to 415 VAC (50/60 Hz); 3-phase 460 to 480 VAC (60 Hz)], DI Option: DI (CH1, CH2 w/Electric Conductivity Control), Pump Option: T2 (20 L/min, CH2 Optical Head)
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
An angled supply port facilitates the supply of circulating fluid, even when units are stacked. A large digital display provides a clear view of the current and set values.
Cooling Capacity: 050 [4600/5100, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: Rc, Option: U (Conforming to UL Standards)
Cooling Capacity: 050 [4600/5100, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option: U (Conforming to UL Standards)
Cooling Capacity: 050 [4600/5100, (50/60 Hz)], Cooling Method: A (Air-cooled), Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option: DMU (DM+U)
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: None, Option 2: Y (w/Feet and No Rack Mounting Brackets)
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: None
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: None
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: None, Option 2: Y (w/Feet and No Rack Mounting Brackets)
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping)
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: M (Applicabe to DI Water Piping)
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: Rc, Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping), Option 2: Y (w/Feet and No Rack Mounting Brackets)
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: N [NPT (w/Rc-NPT Conversion Fitting Set)], Option 1: DM (w/Electric Conductivity Control Function, Applicable to DI Water Piping), Option 2: Z1 (No Flow Sensor or Retaining Clip)
Cooling Capacity: 050 [5000/5900, (50/60 Hz)], Cooling Method: W (Water-cooled), Pipe Thread: F [G (w/Rc-G Conversion Fitting Set)], Option 1: None